TECHNICAL ARTICLES

The Excellence of Instrumentation Cables in Modern Industry
Instrumentation cable is a critical and indispensable component in modern industrial plants and automation systems. Its main function is to ensure the accurate and reliable transmission of low-energy signals, connecting sensors, transmitters, and other measuring devices to control panels and supervisory systems. The integrity of these signals is fundamental for process control, operational safety, and production efficiency. Therefore, engineers and technicians must possess in-depth knowledge of its characteristics, standards, and applications, ensuring the correct selection and installation of this vital component for the technological infrastructure.
| Construction Type | Armor Detail | Protection Level | Ideal Application |
|---|---|---|---|
| Collective (Total) Shielding | A single aluminum strip wrapping around all the pairs/trios. | Protects against noise. External to the end. | Robust digital or analog signals where the pairs do not interfere with each other. |
| Individual + Collective Shielding | Each pair has its own ribbon plus an additional ribbon on the outside. | Protects against external noise. E Crosstalk (peer interference). | Sensitive analog signals (4-20mA), thermocouples, and critical data communication. |
| Braided Pairs | Helically twisted conductors. | Natural cancellation of magnetic fields. | Mandatory standard for any instrumentation cable (NBR 10300). |
| Feature | Standard Specification | Technical Benefit |
|---|---|---|
| Reference norm | ABNT NBR 10300 | Compliance guarantee for national industry and safety. |
| Insulation Voltage | 300V (Maximum) | Suitable for analog signals (does not take up space with excessive isolation). |
| Drivers | Electrolytic Copper (Class 2 or 4) | High conductivity and ease of connection to terminals. |
| Leak | Pairs (Black/White) or Trios (Black/White/Red) | Visual standard to avoid polarity errors during installation. |
1. Standard Instrumentation Cables (BC and IC) The basic line for industrial automation. Designed according to NBR 10300, these cables guarantee clean signal transmission in controlled environments (cable trays and cable ladders).
Variations: Available in collective shielding (BC) for cost-effectiveness or individual shielding (IC) for maximum data protection.
Insulation: PVC (70°C) or HEPR/XLPE (90°C) for higher thermal capacity.
Formations: 2 to 50 pairs. 👉 [ Configure your NBR 10300 Instrumentation Cable ]
2. Armored Instrumentation Cables (Mechanical Protection) For harsh installations where the cable is exposed to physical hazards or rodents. This line adds an extra layer of metallic protection over the inner sheath.
Frame Types: Steel Tape (for protection against crushing and rodents) or Steel Braid/SWA (for tensile strength).
Applications: Direct installation in the ground (buried), mining areas, and heavy infrastructure. 👉 [ Learn about the Armored Instrumentation Cable Line ]
3. Instrumentation Cables for Classified Areas (Ex-i) Critical safety for environments with explosion risk. Although the internal construction is similar to standard cable, the blue outer sheath and controlled capacitance/inductance parameters are vital for intrinsically safe circuits.
Standard: Meets the requirements of IEC 60079-14 for explosive zones.
Use: Oil refineries, chemical plants, and silos. 👉 [ See options for Classified Areas ]
Essential Fundamentals
Instrumentation cable is specifically designed for the transmission of low-voltage, low-current analog or digital signals. Unlike power cables, its construction focuses primarily on protecting signals from external interference. Consequently, it is built with high-purity copper conductors, quality insulation, and, crucially, shielding systems. This structure ensures that measurements of variables such as temperature, pressure, flow, and level are communicated without corruption, allowing for precise and stable process control. The proper selection of this cable is undoubtedly the first step towards the reliability of any automation system.
The Regulatory Importance
The quality and safety of instrumentation cables are governed by a rigorous set of technical standards. In Brazil, the main reference is ABNT NBR 10300, which establishes the requirements for instrumentation cables with extruded PE or PVC insulation for voltages up to 300V. In addition, standards such as ABNT NBR NM 280 (for conductors) and international standards such as those of the IEC (International Electrotechnical Commission) are frequently applied. Consequently, following these guidelines ensures not only the performance of the cable, but also the safety of the installations and the professionals involved.
Construction Structure
The construction of an instrumentation cable is meticulously planned to optimize signal transmission. Typically, it consists of one or more pairs or triplets of electrolytic copper conductors. Each conductor is individually insulated with compounds such as PVC, Polyethylene (PE), or Cross-linked Polyethylene (XLPE), which offer different levels of thermal resistance and dielectric strength. Subsequently, these pairs or triplets are assembled and, in most cases, protected by a shield, demonstrating the complexity and engineering behind a seemingly simple component.
The Function of Insulation
The insulation of conductors in an instrumentation cable plays a fundamental and dual role. Firstly, it prevents electrical contact between conductors of the same pair/triple and between conductors of different groups, preventing short circuits. Secondly, the insulating material, with its dielectric properties, directly influences the cable's capacitance. Low capacitance is desirable to minimize signal distortion, especially over long distances. Therefore, the choice of insulation material, such as 105°C PVC or XLPE, must be compatible with the application and installation environment.
The Importance of Pair Twist in Instrumentation Cables
A key structural feature of instrumentation cable is the twisting of the conductors to form pairs or triplets. This process is not merely for grouping the wires; it has a crucial technical purpose. The helical twisting of the conductors helps to cancel electromagnetic interference (EMI) from external sources, a phenomenon known as common-mode rejection. Thus, by twisting the wires, the noise induced in each conductor tends to be equal and opposite, canceling each other out. This simple yet effective technique significantly improves the signal-to-noise ratio.
The Critical Role of Armor
Shielding is perhaps the most important characteristic of an instrumentation cable , acting as a protective barrier against electromagnetic interference (EMI) and radio frequency interference (RFI). In industrial environments, full of motors, frequency inverters, and power cables, shielding is indispensable. It functions like a Faraday cage, capturing external noise and diverting it to the grounding system through the drain conductor. This ensures that the original, low-energy signal reaches its destination intact, guaranteeing the integrity of the measurement.
Types of Armor
There are basically two types of shielding used in instrumentation cables : aluminized polyester tape shielding and copper braid shielding. Aluminum tape offers 100% coverage and is particularly effective against high-frequency noise (RFI). On the other hand, copper braid, although with less coverage, provides lower electrical resistance and greater mechanical robustness, being more efficient at low frequencies (EMI). Often, a combination of both is used to protect the cable against a wide range of interference frequencies.
Individual and Collective Shielding of Instrumentation Cables
The protection offered by shielding can be applied in two ways to instrumentation cables . Collective (or total) shielding involves enveloping all pairs/triples of the cable with a single layer of protection. Individual shielding, on the other hand, applies an aluminum tape to each pair or triplet, which can be complemented by collective shielding. Individual shielding is superior because, in addition to protecting against external noise, it also mitigates crosstalk, which is interference between signals traveling on adjacent pairs of the same cable.
Drain Pipe
Directly associated with the tape shielding, the drain conductor is an essential element of the instrumentation cable . It is a tinned copper conductor that is in continuous contact with the metallic part of the shielding. Its function is to facilitate the connection of the shielding to the system's grounding terminal. Since the aluminum tape is fragile and difficult to connect, the drain provides a practical and electrically efficient termination point, ensuring that noise captured by the shielding has a low-impedance path to ground.
Applications of Instrumentation Cable in Industrial Automation
In industrial automation, instrumentation cable is the backbone of field communication. It is widely used to interconnect proximity sensors, flow meters, pressure and temperature transmitters to Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS). Due to its reliability, it allows for real-time monitoring and precise loop control, resulting in greater efficiency, product quality, and operational safety. Therefore, choosing the correct cable for each signal is a critical engineering decision.
Use of Instrumentation Cable in Process Industries
The chemical, petrochemical, and oil and gas industries rely heavily on instrumentation cables to operate safely and efficiently. In these often hostile environments with classified areas, cables need to have special characteristics, such as resistance to chemicals, oils, and UV exposure. Furthermore, for intrinsically safe circuits, cables must have a specific color (usually light blue) and meet stringent standards, such as IEC 60079-14, to ensure they do not become a source of ignition in potentially explosive atmospheres.
Instrumentation Cable in Classified Areas
In locations where flammable gases, vapors, or dust are present (classified areas), the use of appropriate instrumentation cable is a non-negotiable safety requirement. For intrinsically safe (Ex-i) circuits, the cable must have controlled capacitance and inductance parameters to limit the stored energy to levels that cannot cause ignition. These cables often have a blue outer sheath and must be installed following specific practices to maintain the integrity of the intrinsic safety concept, preventing serious accidents.
Specifying the Correct Instrumentation Cable
Specifying an instrumentation cable requires analyzing several factors. First, the signal type (4-20 mA analog, thermocouple, digital, etc.) and the number of conductors required (pair, triple, or multi-pair) must be considered. Next, the installation environment will dictate the need for shielding, insulation type (PVC, PE, XLPE), outer covering (resistance to weather, oils, etc.), and, if applicable, armor for mechanical protection. A detailed and correct specification avoids performance problems and future replacement costs.
Difference between Instrumentation Cable and Control Cable
Although both are used in automation, instrumentation cable and control cable have distinct purposes. Instrumentation cable is designed for the faithful transmission of low-energy measurement signals, with noise protection being its main characteristic. On the other hand, control cable is used for command and interlocking signals, such as switching a motor on or off via a contactor. Generally, control cable operates with higher voltages and currents and may not require the same level of shielding.
Proper Installation
The performance of an instrumentation cable fundamentally depends on its correct installation. It is crucial that signal cables are installed in trays or conduits separate from power cables to minimize noise induction. The minimum bending radius must be respected to avoid damaging the internal structure of the cable. Additionally, shield grounding should be done at a single point, usually at the control panel, to avoid the creation of "ground loops," which can paradoxically introduce noise into the system.
Grounding of the Instrumentation Cable Shield
Proper grounding of instrument cable shielding is vital to its effectiveness. The shielding should be connected to ground at only one end of the cable, typically on the panel or data acquisition system side. Leaving the other end (on the field instrument side) disconnected (floating) prevents current from flowing through the ground loops, which are a common source of interference. This simple installation rule is often overlooked, but it is essential for a clean and accurate measurement system.
Mechanical Protection
In harsh industrial environments where there is a risk of crushing, impact, or rodent attack, instrumentation cable may require additional mechanical protection. This is achieved through an armor, which can be made of steel tape or galvanized steel wire (SWA – Steel Wire Armour), applied over the cable's inner sheath. Subsequently, an outer sheath is applied over the armor. This robust construction ensures the cable's physical integrity, protecting the investment and operational continuity in heavy-duty installations.
Resistance to Flame and Fire
Fire safety is a growing concern in all installations. Therefore, instrumentation cables can be manufactured with materials that offer enhanced safety characteristics. Low smoke zero halogen (LSZH) cables are specified for areas with high concentrations of people, such as tunnels and subway stations. In addition, there are fire-resistant cables, designed to maintain circuit integrity for a certain time even under direct fire, according to standards such as IEC 60331.
The Future and Evolution of Instrumentation Cables
The continuous evolution of technology and the growing demand for data in Industry 4.0 are driving innovation in the field of instrumentation cable . There is constant development in insulation and sheathing materials, offering greater strength and durability. Furthermore, the integration of technologies, such as hybrid cables that combine instrumentation pairs with optical fibers, is becoming more common to meet the need for high data transmission rates over long distances. Thus, instrumentation cable will continue to be a key component, adapting to new technological demands.
Technical Questions about Instrumentation Cables (NBR 10300)
Question 1: What is the difference between instrumentation cable and control cable? Answer: The main difference is the application and voltage. Instrumentation cable (300V) is designed to transmit low-power signals (4-20mA, 0-10V) with high precision and protection against interference (mandatory shielding). Control cable (500V/750V) is used to operate equipment (coils, relays, motors) and does not always require sophisticated shielding.
Question 2: Why are the pairs twisted in instrumentation? Answer: Twisting the pairs serves to cancel electromagnetic interference. When the wires are twisted, the magnetic field generated by one wire cancels that of the other, ensuring that the signal reaches the receiver cleanly. This is essential for protocols such as HART, Foundation Fieldbus, and analog signals.
Question 3: What do the acronyms ITA and ITB mean? Answer: These are market terms used to describe shielding. ITA (or Individual Shielding) means that each pair or trio has its own protection. ITB (or Collective Shielding) means that only the entire set of cables has overall shielding. The choice depends on the signal sensitivity.
Instrumentation cable and its applications
Related Articles

Everything about concentric cable: standards and applications.
Concentric Cable: A Complete Technical Guide for Engineers and Installers. Concentric cable represents an advanced engineering solution for networks.

Trends in Industrial Cables for 2026
Trends in industrial cabling combine automation, data, safety, and durability. Learn how to specify solutions for critical field environments.

Cable selection for frequency inverter
Selecting the right cable for your inverter reduces faults, noise, and downtime. Learn about the electrical, construction, and regulatory criteria for a safe specification.

Critical Safety: When to Specify a High-Performance vs. Conventional Fire Cable
In life safety systems, such as fire detection and alarm systems, the cable specification
Knowledge Academy: Technical information, standards and applications

Tables and Codes for Thermocouples
International Color Code for Compensation and Extension Cables and Wires - Cable Code - Error Limit Table

NBR 5410 Sizing Tables
DOWNLOAD NBR 5410 DIMENSIONING TABLES Explanation With the aim of offering a practical tool to assist in the work of

Color code tables
Color code according to DIN 47100 No. Colour Short Form 1 WHITE WH 2 BROWN BN 3

TABLE AND GUIDELINES AWG X METRIC CONVERSION (mm²)
Unveiling the AWG Standard: A Technical Guide for Professionals and Enthusiasts – American Wire Gauge (AWG) to Metric (mm²) Conversion
Questions? Send a message to the expert.
Access to cutting-edge scientific information is the fuel for innovation. These are the databases, journals, and repositories that our R&D team uses to stay at the forefront of global technical and scientific knowledge.
Databases, Repositories and Search Engines:
- IEEE Xplore Digital Library: The most crucial digital library for electrical and computer engineering. IEEE
- ACM Digital Library: A reference for the field of computer science and information technology. ACM
- Science Direct: Extensive collection of scientific publications and books from the publisher Elsevier. SCIENCE DIRECT
- Scopus: The largest database of abstracts and citations from peer-reviewed literature. scopus
- CAPES Journal Portal: It provides access to international scientific output for the teaching and research community in Brazil. CAPES
- Google Scholar Search tool focused on academic literature. GOOGLE SCHOLAR
- Brazilian Digital Library of Theses and Dissertations (BDTD): Repository of scientific output from Brazilian teaching and research institutions. BDTD
- Directory of Open Access Journals (DOAJ): A directory of high-quality open access journals. DOAJ
Prominent Scientific Periodicals and Journals:
- Naval, Offshore and Petroleum Engineering:
- Ocean Engineering (Elsevier)
- Journal of Ship Research (SNAME)
- Journal of Petroleum Science and Engineering (Elsevier)
- Journal of Marine Science and Engineering (MDPI)
- Journal of the Brazilian Society of Naval Engineering (SOBENA)
- Electrical, Electronic and Telecommunications Engineering:
Products

Profibus DP DeepSea® Armed SHF2
Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; 1x2x0,64; SHF2; Flame retardant: IEC 60332-1-2; violet; 8 mm

MariTimus® Single-Core Marine Power and Control Cable 0,6/1 kV XLPE/SHF1 (LSOH) Armored and Flame Retardant
Maritimus® Single-Core Naval Power and Control Cable; Armored; Max. 300,00 mm²; 0,6/1 kV; 1 conductor; XLPE / SHF1; Flame Retardant; +90°C; IEC 60092

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Fire Resistant IEC 60331
Maritimus® Single-Core Marine Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Armored and Fire Resistant IEC 60331
Maritimus® Armored Multicore Naval Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331