ARMORED INSTRUMENTATION CABLE

Instrumentation Cables, The Definitive Guide: Standards, Applications and Technical Specifications

 

Instrumentation cable is a fundamental component in the arteries of any modern industrial plant, being essential for automation and process control. It is specifically designed to transmit low-energy signals with maximum reliability, ensuring that information from sensors, transmitters, and other measuring devices reaches control systems intact, such as PLCs (Programmable Logic Controllers) and DCSs (Distributed Control Systems). Consequently, the correct choice and application of this cable are crucial for operational safety, process efficiency, and data integrity, preventing unexpected downtime and production losses.

Type of ArmorMarket AcronymProtection OfferedIdeal Application
Collective (Total) ShieldingBC / MAProtection against external noise on the cable.General analog signals (4-20mA), alarms and thermocouples in standard environments.
Individual and Collective ProtectionIC / I/C / MBExternal + Crosstalk between peersCritical signals, high speed, and multiple sensitive instruments on the same cable.
Intrinsic Security (Ex-i)Blue CoverIdentification for Explosive AreasChemical, Oil and Gas Industry (Classified Zones).

1. Collectively Shielded Instrumentation Cables (CS) The industry standard solution. Constructed in twisted pairs or triples to cancel the magnetic field, these cables have an aluminized polyester tape that wraps around all conductors at once.

  • Function: Protects signals against electromagnetic interference (EMI) coming from outside the cable (e.g., nearby motors).

  • Applications: Interconnection of analog sensors (4-20mA), level transmitters and valves to the supervisory system.

  • Standards: Manufactured according to NBR 10300. 👉 [ See the BC Instrumentation Cable Datasheet ]

2. Instrumentation Cables with Individual and Collective Shielding (IC) For when absolute precision is required. In addition to general shielding, each pair has its own aluminum tape and drain wire. This prevents crosstalk , which occurs when the signal from one pair interferes with the neighboring pair within the same cable.

  • Function: Ensures complete signal isolation between different instruments connected to the same multi-core cable.

  • Applications: DCS (Distributed Digital Control System) systems and high-frequency digital signals. 👉 [ Learn about the Individual Shielding Line (BFI) ]

3. Intrinsically Safe Cables (Blue Sheath) Mandatory safety in hazardous areas. Technically identical to the previous ones, but with the outer sheath in blue , indicating that the circuits are low energy and do not generate sparks capable of detonating explosive atmospheres.

  • Applications: Classified zones (Ex) in refineries, pharmaceutical industries and grain silos.

  • Key point: Essential for compliance with IEC 60079-14 standard. 👉 [ Access Cables for Classified Areas ]

The Critical Importance of Cable for Instrumentation

 

In industrial environments, precision is imperative. Therefore, the main function of an instrumentation cable is to ensure the transmission of signals without degradation or interference. Unlike power cables, it operates with very low voltages and currents. Thus, any electromagnetic noise can distort the information, leading to incorrect readings and erroneous control decisions. Therefore, the robust construction and specific electrical characteristics of this type of cable are vital for the reliability of the entire control system, from flow and temperature measurement to the actuation of valves and actuators.

 

Main Brazilian Standard for Instrumentation Cable

 

The quality and safety of instrumentation cables are governed by rigorous technical standards. In Brazil, the main reference is ABNT NBR 10300, which specifies the performance requirements for instrumentation cables with extruded PE (polyethylene) or PVC (polyvinyl chloride) insulation for voltages up to 300 V. Therefore, this standard details everything from the materials used in the conductors and insulation to the test methods to ensure that the cable withstands industrial conditions, offering a quality and safety standard for engineers and installers.

 

International Standards

 

In addition to local regulations, large-scale or export-oriented projects often require compliance with international standards. Among these, the IEC (International Electrotechnical Commission) standards are widely recognized. They serve as a basis for global technical harmonization, ensuring that instrumentation cables meet globally accepted performance and safety requirements. Therefore, familiarity with these standards is essential for engineers working on multinational projects, ensuring interoperability and component quality anywhere in the world.

 

General Applications

 

Versatility is a hallmark of instrumentation cable , which finds application in virtually all industrial sectors. Primarily, it is used to connect measuring instruments (pressure, level, flow, temperature) to control rooms. Furthermore, it is fundamental in fire and gas detection systems, alarms, and safety interlock circuits. Its application, therefore, ranges from the petrochemical and pulp and paper industries to mining and the food sector, being an indispensable link in the automation and control chain.

Cable TypeshieldingInsulationTensãoMain Application
MA Instrumentation (Armored)Aluminized Polyester Tape + DrainPVC or PE (70°C to 105°C)300VAnalog signals 4-20mA, moderate noise environments.
ITA/ITB Instrumentation (Pair/Trio)Individual per pair + Total CollectivePVC/HEPR/XLPE300V / 600VHigh precision, maximum protection against interference (crosstalk).
Naval Instrumentation CableCopper Braid or Tape (IEC 60092)HEPR / XLPE (90°C)150/250V (300V)Ships and Offshore (Naval Certification).

 

Specific Use in the Petrochemical Sector

 

In the petrochemical sector, operating conditions are extremely harsh, with the presence of aggressive chemical agents, high temperatures, and classified areas with explosion risks. In this scenario, instrumentation cables need to have special characteristics, such as an outer covering resistant to hydrocarbons and UV rays. Frequently, cables with non-halogenated compounds (LSHF/LSZH) are specified, which, in case of fire, emit low amounts of smoke and toxic gases, increasing the safety of installations and personnel. Consequently, careful cable specification is a fundamental safety measure.

 

The Role of Instrumentation Cables in Process Automation

 

Modern industrial automation relies on uninterrupted and precise communication between thousands of measurement and control points. Instrumentation cabling is the physical pathway for this communication, transmitting everything from traditional analog signals, such as 4-20 mA, to digital protocol data such as HART, Fieldbus, and Profibus PA. Consequently, the integrity of the signal transmitted through this cable directly affects the automation system's ability to optimize processes, reduce operating costs, and make real-time decisions, making it a cornerstone of Industry 4.0.

 

Construction of instrumentation cables: The conductors

 

The heart of an instrumentation cable is its conductor, usually made of bare or tinned high-purity electrolytic copper wires. Tinned copper, for example, offers greater corrosion resistance, making it ideal for more aggressive environments. Conductors are stranded in classes that define their flexibility (such as Class 2 or Class 5), according to the ABNT NBR NM 280 standard. The correct choice of stranding class facilitates installation, especially in complex infrastructures with sharp bends, while ensuring a stable and low-resistance electrical connection.

 

Types of insulation for instrumentation cable

 

Individual conductor insulation is vital to prevent short circuits and ensure correct signal transmission. Various materials are used, each with specific properties. PVC (Polyvinyl Chloride) is the most common, offering good dielectric strength and low cost. For higher operating temperatures or greater robustness, PE (Polyethylene) or XLPE (Cross-linked Polyethylene) are used. Therefore, the choice of insulation material for instrumentation cables should be based on ambient temperature, signal voltage, and the presence of chemical agents at the installation site.

 

Advantages of LSHF Insulated Instrumentation Cable

 

Human safety is a top priority in any project. In locations with high pedestrian traffic or in confined spaces, such as oil platforms and subway stations, the use of LSHF (Low Smoke Halogen Free) insulated and sheathed instrumentation cable is mandatory. In case of fire, this compound emits a significantly lower volume of smoke and does not release toxic and corrosive halogen gases. Consequently, it facilitates the evacuation of people, protects sensitive electronic equipment, and minimizes property damage, representing a safe and responsible choice.

 

The Essential Function of Shielding in Instrumentation Cables

 

Shielding is perhaps the most distinctive feature of instrumentation cable . Its function is to protect low-energy signals against electromagnetic interference (EMI) and radio frequency interference (RFI), generated by motors, frequency inverters, power cables, and other common noise sources in the industrial environment. Without effective shielding, signals can be corrupted, leading to erratic measurements and control failures. Therefore, shielding is not an option, but a technical necessity to ensure the integrity and reliability of the system.

 

Shielding with aluminized polyester tape on the instrumentation cable.

 

One of the most effective types of shielding for instrumentation cable is aluminized polyester tape. This shielding consists of a thin aluminum tape laminated onto a polyester film, applied helically over the pairs or the entire conductor array. It offers 100% coverage and is particularly efficient in protecting against high-frequency noise (RFI). It is usually accompanied by a tinned copper drain conductor in continuous contact with the metallic part of the tape, which ensures the continuity of the shielding and facilitates proper grounding.

 

Understanding Individual and Collective Protection

 

Shielding can be applied in two main ways. Collective (or total) shielding involves covering the entire set of pairs or triples of the cable with a single layer of protection. On the other hand, individual shielding applies an aluminized tape to each pair or triple, in addition to collective shielding. This latter configuration, known as BI+BC, is superior because, in addition to protecting against external noise, it also minimizes crosstalk, which is interference between signals from adjacent pairs. Therefore, it is the ideal choice for more sensitive signals or for transmitting different types of signals on the same cable.

 

Electrical Continuity: The Role of the Drain

 

The drain conductor is an essential element that works in conjunction with the tape shielding. It is a flexible tinned copper conductor that is positioned in direct contact with the metallic face of the shielding along the entire length of the instrumentation cable . Its main function is to ensure easy and efficient termination of the shielding system to the grounding point in the control panel or junction box. In this way, the drain ensures the electrical continuity of the shield and safely drains noise currents to ground.

 

The outer sheath of instrumentation cable and its resistance.

 

The outer jacket, or sheath, is the first line of defense for instrumentation cables against the environment. It protects the internal components from mechanical damage, moisture, dust, chemicals, and solar radiation (UV). The most common materials for the sheath are PVC, which is durable and versatile, and LSHF compounds for safety applications. Depending on the installation environment, steel wire or tape reinforcement may be added for extra protection against crushing or rodent attack, ensuring the cable's longevity and durability in adverse conditions.

 

Pair and trio identification in instrumentation cable.

 

To facilitate installation and avoid wiring errors, the conductors of an instrumentation cable are identified by color. The ABNT NBR 10300 standard establishes color codes for identifying pairs (usually black and white) and triples (black, white, and red). In multi-pair cables, in addition to colors, the pairs are sequentially numbered through markings on the insulation or on tapes applied over them. This clear and standardized identification is fundamental to speeding up the installer's work and ensuring the correct commissioning of the system, significantly reducing startup time.

 

Transmitting Analog Signals with Instrumentation Cable

 

The most ubiquitous analog signal in the industry is the 4-20 mA standard. In this system, the instrumentation cable transmits a direct current whose value is proportional to the measured process variable (e.g., 4 mA for 0% and 20 mA for 100% of the scale). The great advantage of this method is its high immunity to induced noise and voltage drop along the cable, compared to voltage signals. However, for it to function perfectly, the integrity of the cable is essential, as any current leakage or high resistance can compromise the accuracy of the reading.

 

The compatibility of instrumentation cable with digital signals.

 

With the advancement of automation, digital communication protocols, such as Foundation Fieldbus and Profibus PA, have gained prominence. They allow multiple instruments to communicate on the same pair of wires, transmitting not only the process variable but also diagnostic and configuration information. For these networks, a specific instrumentation cable is required , designed with controlled characteristic impedance (usually 100 Ω) and low capacitance. Using an unsuitable cable can cause signal reflections and communication errors, compromising the entire automation network.

 

Best Practices for Instrumentation Cable Installation

 

Proper installation is just as important as cable quality. First, instrumentation cable must be installed in cable trays or conduits separate from power cables, maintaining a safe distance to avoid noise induction. Additionally, the minimum bending radius specified by the manufacturer must be respected to avoid damaging the cable's internal structure. Finally, shield grounding should be done at a single point, usually on the control panel side, to prevent the creation of ground loops, which can introduce noise into the system.

 

Requirements in Classified Areas

 

In environments with a risk of explosion (classified areas), such as refineries or chemical plants, intrinsically safe (“Ex-i”) circuits are required. These circuits operate with such low energy that they are incapable of igniting the explosive atmosphere. The instrumentation cable used in these circuits, often identified by its blue outer sheath, must comply with the requirements of IEC 60079-14. This standard establishes rigorous criteria for the capacitance and inductance parameters of the cable, which are crucial for calculating the maximum length of the run and for ensuring the intrinsic safety of the system.

 

How to Specify the Correct Instrumentation Cable for Your Project

 

Properly specifying instrumentation cable is an engineering task that requires attention to multiple factors. First, the installation environment must be analyzed to define the requirements for sheathing (PVC, LSHF), armor, and resistance to chemical agents. Next, the signal type (analog, digital) and the need for individual and/or collective shielding to protect against noise must be considered. Finally, compliance with applicable ABNT and IEC standards ensures performance and safety. By taking all these points into account, the engineer ensures the selection of the most reliable solution with the best cost-benefit ratio.

 

The Future and Innovation in Instrumentation Cables

 

The field of instrumentation cables continues to evolve, driven by the demands of Industry 4.0 and the Internet of Things (IoT). Trends point towards cables with higher data transmission rates to support more advanced network protocols, such as Ethernet-APL (Advanced Physical Layer). Furthermore, there is continuous development of more robust and sustainable materials. Innovation seeks to create cables that not only transmit signals but also integrate intelligence and contribute to more efficient, secure, and connected control systems, solidifying their role as an irreplaceable component in industrial technological infrastructure.

 

Question 1: What is the difference between "Control Cable" and "Instrumentation Cable"? Answer: This is the most common question.

  • Control Cable: It is used to turn things on and off (on/off switches, contactors). Its conductors are parallel (not twisted) and the insulation is for higher voltages (500V/1000V).

  • Instrumentation Cable: Used to read data (temperature, flow, pressure). Its conductors are necessarily twisted pair to avoid magnetic noise and have shielding to ensure that the 4-20mA signal reaches the central computer (PLC) cleanly. Typical insulation voltage: 300V.

Question 2: Why do the pairs need to be twisted? Answer: Twisting (Twisted Pair) is a physical technique for noise cancellation. When electromagnetic interference hits the cable, it affects both wires of the pair equally. Because they are twisted, the voltage induced in one wire cancels out that of the other at the differential input of the receiving equipment. Without twisting, the sensor reading would be unstable and inaccurate.

Question 3: What is the drain wire? Answer: Because the shielding is made of polyester-aluminum tape (a metallized plastic material), it is not possible to solder a wire to it for grounding. The drain wire is a tinned copper conductor that runs in constant contact with the metallic part of the tape along the entire cable. Its function is to "drain" the parasitic currents picked up by the shielding and allow easy connection to ground in the panel.

Instrumentation Cable: Types and Characteristics

Related Articles

Knowledge Academy: Technical information, standards and applications

Questions? Send a message to the expert.

Access to cutting-edge scientific information is the fuel for innovation. These are the databases, journals, and repositories that our R&D team uses to stay at the forefront of global technical and scientific knowledge.

Databases, Repositories and Search Engines:

  • IEEE Xplore Digital Library: The most crucial digital library for electrical and computer engineering. IEEE
  • ACM Digital Library: A reference for the field of computer science and information technology. ACM
  • Science Direct: Extensive collection of scientific publications and books from the publisher Elsevier. SCIENCE DIRECT
  • Scopus: The largest database of abstracts and citations from peer-reviewed literature. scopus
  • CAPES Journal Portal: It provides access to international scientific output for the teaching and research community in Brazil. CAPES
  • Google Scholar Search tool focused on academic literature. GOOGLE SCHOLAR
  • Brazilian Digital Library of Theses and Dissertations (BDTD): Repository of scientific output from Brazilian teaching and research institutions. BDTD
  • Directory of Open Access Journals (DOAJ): A directory of high-quality open access journals. DOAJ

Prominent Scientific Periodicals and Journals:

  • Naval, Offshore and Petroleum Engineering:
    • Ocean Engineering (Elsevier)
    • Journal of Ship Research (SNAME)
    • Journal of Petroleum Science and Engineering (Elsevier)
    • Journal of Marine Science and Engineering (MDPI)
    • Journal of the Brazilian Society of Naval Engineering (SOBENA)
  • Electrical, Electronic and Telecommunications Engineering:
    • IEEE Transactions on Power Systems (Available via IEEE Xplore)
    • IEEE Transactions on Power Delivery (Available via IEEE Xplore)
    • IEEE Transactions on Communications (Available via IEEE Xplore)
    • Telecommunications Magazine (Inatel): INATEL
    • Control & Automation Magazine (SBA): SBA

Products

Profibus DP Black double shielded cable, SHF2 DeepSea crossbar
Instrumentation cables - flame retardant SHF2

Profibus DP DeepSea® Armed SHF2

Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; 1x2x0,64; SHF2; Flame retardant: IEC 60332-1-2; violet; 8 mm

Read more "