TECHNICAL ARTICLES

Excellence in Connectivity: The Definitive Guide to Shielded Instrumentation Cables
Os shielded cables for instrumentation Cables represent a critical component in the backbone of any modern industrial automation and control system. Essentially, their primary function is to ensure the complete and reliable transmission of low-energy signals, connecting sensors, transmitters, and other devices to control panels and data acquisition systems. Due to the sensitivity of these signals, protection against electromagnetic interference (EMI) and radio frequency interference (RFI) is not just a luxury, but an absolute necessity for the accuracy and safety of processes. Consequently, the correct specification and application of these cables are vital for engineers, installers, and students seeking technical excellence.
Comparative Analysis: Types of Shielding for Instrumentation (NBR 10300)
| Shielding Configuration | Common Abbreviation | Protection Offered | Recommended Application |
|---|---|---|---|
| Collective (Total) Shielding | Bt / OS (Overall Shield) | Protects the entire cable from external noise. | Environments with general electromagnetic noise, where internal signals do not interfere with each other. |
| Individual + Collective Shielding | Bdc / IS+OS (Individual & Overall) | Eliminate Crosstalk (interference between pairs) + External noise. | Sensitive analog signals, fast digital protocols, and high-precision measurements. |
| Copper Braided Shielding | Mesh / TC | High mechanical strength and protection at low frequencies. | Areas with light vibration or requiring greater physical robustness. |
The Regulatory Importance
The quality and safety of shielded cables for instrumentation These systems are governed by rigorous technical standards. In Brazil, the main reference is ABNT NBR 10300, which specifies the performance and construction requirements for instrumentation cables with voltages up to 300 V. Additionally, standards such as NBR 7289, for control cables, may be applicable depending on the complexity of the system. These guidelines ensure that the final product possesses the necessary characteristics of insulation, flame propagation resistance, and, crucially, shielding effectiveness, thus guaranteeing safe and compliant operation for any industrial plant.
Advanced Solutions in Instrumentation Cables
1. Instrumentation Cable with Individual and Total Shielding (Type Bdc) The technical choice to avoid the "crosstalk" effect. In this model, each pair or trio has its own aluminum tape, in addition to the overall shielding. Essential for industrial plants where multiple sensor signals travel on the same cable without distortion.
Standard: NBR 10300.
Featured: Absolute signal integrity.
👉 [View details of Individual and Total Instrumentation Cable]
2. Armored Instrumentation Cable (Mechanical Protection) For installations in aggressive environments or directly buried, we offer the option with Frame made of steel tape or galvanized steel braid.This extra layer protects the electromagnetic shielding against crushing, cuts, and rodents.
Application: Petrochemical Industry and Infrastructure.
The Critical Function
In industrial environments, the prevalence of motors, frequency inverters, and other high-power loads generates significant electromagnetic "noise." shielded cables for instrumentation They are specifically designed to combat this phenomenon. Through their construction with metallic shielding, they create a Faraday cage around the internal conductors. Therefore, this protective barrier intercepts and diverts interference to the grounding system, ensuring that the original signal, whether it is 4-20 mA, from a thermocouple or a digital protocol, reaches its destination without corruption and with maximum precision.
Types of Armor
The effectiveness of a shielded cable for instrumentation This is directly related to the type of shielding used. Aluminized polyester tape (APF) shielding offers 100% coverage, being particularly effective against high-frequency noise (RFI). On the other hand, copper wire mesh (CW) shielding, bare or tinned, provides greater mechanical strength and better performance at low frequencies (EMI). For extremely harsh environments, a combination of tape and mesh offers the most robust and complete protection against a wide range of interferences.
The Structure of Conductors
The heart of shielded cables for instrumentation These are its conductors, generally manufactured from high-purity electrolytic copper. The choice of stranding class, such as class 2 (rigid) or class 5 (flexible), directly impacts the cable's malleability during installation. While more rigid cables are suitable for fixed installations in trays and cable ducts, flexible cables are preferable in applications requiring movement, such as in control panels or in connecting vibrating equipment. The correct selection, therefore, optimizes both the installation and the component's lifespan.
Insulation and Covering
The insulation and covering materials of shielded cables for instrumentation These materials are fundamental to its durability and safety. Compounds such as PVC (Polyvinyl Chloride) and PE (Polyethylene) are widely used in the insulation of the conductors, offering excellent dielectric properties. The outer covering, often made of PVC, can be specified to have special characteristics, such as UV resistance for outdoor installations, resistance to oils and greases in harsh industrial environments, and, crucially, non-flame propagating and self-extinguishing properties, increasing plant safety.
The Application of Shielded Cables for Instrumentation in Pairs or Triples
To optimize signal transmission and minimize crosstalk between adjacent circuits, the shielded cables for instrumentation They are often constructed with conductors twisted in pairs or triples. This twisting helps to electromagnetically cancel interference generated between the conductors themselves. In multi-pair cables, it is common to use individual shielding on each pair/triple, in addition to collective shielding over the entire assembly, providing a double barrier of protection and ensuring maximum integrity for multiple signals traveling in the same cable.
The Role of the Drain
An essential and often underestimated element in shielded cables for instrumentation This is the drain conductor. This tinned copper wire, in continuous contact with the metallic shield (usually aluminum tape), facilitates the connection of the shield to the grounding system. Instead of trying to connect the fragile aluminum tape to a terminal, the installer simply connects the drain. This practice ensures a 360° termination and a low-impedance path to ground, and is therefore vital to the effectiveness of the shielding system.
Selecting Shielded Cables for Instrumentation Sensors
The selection of shielded cables for instrumentation When connecting sensors and transmitters, the nature of the signal must be considered. For low-voltage and low-current analog signals, such as those from thermocouples or load cells, noise protection is absolutely critical for measurement accuracy. For transmitters with superimposed digital communication, such as the HART protocol, cable quality ensures not only process reading but also communication for device configuration and diagnostics. Therefore, careful selection is a fundamental step in the design.
Shielded Cables for Instrumentation in Industrial Automation
In industrial process automation, reliability is non-negotiable. shielded cables for instrumentation These cables are the backbone that interconnects PLCs (Programmable Logic Controllers), supervisory control and data acquisition (SCADA) systems, and field devices. They are used in control, signaling, alarm, and measurement circuits. A failure in signal transmission can lead to production stoppages, loss of quality, or even operational hazards. Therefore, investing in high-performance cables is a protective measure for all industrial assets.
The Importance of Grounding in Shielded Instrumentation Cables
The effectiveness of a shielded cable for instrumentation It intrinsically depends on a proper grounding system. The shield should be grounded at only one point, usually on the control panel or PLC side. This technique, known as single-wire grounding, avoids the creation of "ground loops," which can induce unwanted currents in the mesh and, paradoxically, turn the shield itself into a noise source. Following this installation practice is therefore as important as choosing the cable itself.
Shielded Cables for Instrumentation in Classified Areas
In the chemical, petrochemical, oil and gas industries, there are areas classified as having a risk of explosion. In these zones, the shielded cables for instrumentation They must meet even more stringent requirements. In addition to EMI protection, they may need to be intrinsically safe (Ex-i), designed to limit electrical energy to levels that cannot cause ignition of explosive atmospheres. Compliance with standards such as IEC 60079-14 is mandatory, ensuring that the cables contribute to the overall safety of the installation.
Shielded Cables for Instrumentation and Communication Protocols
With the advancement of Industry 4.0, the shielded cables for instrumentation These protocols are increasingly used in industrial communication networks. Protocols such as Profibus PA and Foundation Fieldbus, which operate over a single-pair bus, depend on cables with controlled impedance and effective shielding to ensure digital communication between multiple instruments and the control system. Correct cable specification is a prerequisite for the stable and reliable operation of these digital fieldbuses.
Chemical and Thermal Resistance of Shielded Cables for Instrumentation
The industrial environment can be extremely harsh, with exposure to chemicals, oils, and extreme temperatures. For this reason, it is possible to specify shielded cables for instrumentation with special coatings that offer high resistance to these agents. Materials such as polyurethanes or thermoplastic elastomers can be used to ensure the integrity of the cable in locations with frequent chemical spills. Similarly, for high temperatures, silicone insulation or other special compounds ensure continuous and safe operation.
Correct Installation
Professional installation is crucial for the performance of shielded cables for instrumentationIt is essential to avoid installing signal cables in the same trays or conduits as high-current power cables. When crossing is unavoidable, it should be done at 90 degrees to minimize noise induction. Furthermore, the minimum bending radius specified by the manufacturer must be respected to avoid damage to the cable's internal structure, which could compromise both insulation and shielding effectiveness.
Maintenance and Service Life of Shielded Instrumentation Cables
Although designed for long durability, predictive maintenance of shielded cables for instrumentation It is good practice. Visual inspections for damage to the outer sheath, especially in areas of high vibration or exposure to the elements, can prevent future failures. Checking the integrity of the grounding connections is also crucial. A well-specified and correctly installed cable can have a lifespan of decades; however, periodic monitoring ensures that it continues to deliver peak performance and reliability throughout its entire lifecycle.
The Advantage of Individual and Collective Shielding in Shielded Instrumentation Cables
For applications that require the transmission of multiple sensitive signals over a single cable (multipair), the use of shielded cables for instrumentation Individually and collectively shielded (BIC) signals are the ideal solution. Each pair or triple has its own aluminum tape shielding, protecting signals against mutual interference (crosstalk). Additionally, overall collective shielding protects the entire assembly against external interference. This robust construction is the preferred choice for optimizing tray space without sacrificing signal integrity.
Shielded Instrumentation Cables Resistant to UV Radiation
In outdoor installations, such as solar plants, oil platforms, or open industrial areas, the shielded cables for instrumentation They are directly exposed to ultraviolet (UV) radiation from the sun. UV radiation can rapidly degrade conventional sheathing materials, leading to cracking and loss of mechanical protection and insulation. Therefore, it is essential to specify cables with an outer sheath containing anti-UV additives, usually in black, which guarantee the cable's resistance and longevity even under constant sun exposure.
Identification and Coding of Cores in Shielded Instrumentation Cables
To facilitate installation and maintenance, the shielded cables for instrumentation They have clear and standardized conductor identification systems. NBR 10300 establishes color codes or numbering for individual conductors, pairs, and triples. This coding allows the installer to correctly connect the cable ends without risk of errors, which is especially critical in multi-pair cables with dozens of conductors. Precise identification saves commissioning time and simplifies future maintenance interventions on the system.
The Future and Innovation
The field of shielded cables for instrumentation The field continues to evolve, driven by demands for higher data rates, greater resistance to harsh environments, and integration with IIoT (Industrial Internet of Things) technologies. Research focuses on new insulation and shielding materials that are lighter, more flexible, and offer superior performance at high frequencies. Consequently, partnering with a specialized and innovative supplier guarantees access to the most advanced solutions for the connectivity challenges of the present and the future.
Technical Questions about Shielded Cables for Instrumentation
Question 1: What is the function of the "Drain Wire" in shielded cables? Resposta: The drain wire is a tinned copper conductor that is in constant contact with the aluminum tape (shielding). Its function is to facilitate grounding of the shielding. By connecting the drain to ground on the panel, you "drain" the parasitic currents induced by electromagnetic interference, ensuring that the instrument signal reaches the controller cleanly.
Question 2: Can I use instrumentation cable to connect motors or solenoid valves? Resposta: Caution. Instrumentation cables (NBR 10300) are designed for low-power signals (generally 300V) and very low current. For power supply, valves, or motors, the correct option is to use... Control Cables (NBR 7289) or Power, which have insulation for 500V/1kV and conductors sized for higher currents. Using instrumentation for power can cause overheating and insulation failure.
Question 3: What is the difference between pairs and triplets in instrumentation? Resposta: The cables are formed by twisted assemblies.
Pairs (2 ways): Used for most analog (4-20mA) and simple digital signals.
Three-way (3-way) trios: Used when the instrument requires a third wire (e.g., separate power supply, 3-wire RTDs, or redundancy). Innovcable manufactures both options with full or individual shielding, identified by colors (black/white or black/white/red) and sequential numbering.
Shielded Cables for Instrumentation: What Are They?
Related Articles

Everything about concentric cable: standards and applications.
Concentric Cable: A Complete Technical Guide for Engineers and Installers. Concentric cable represents an advanced engineering solution for networks.

Critical Safety: When to Specify a High-Performance vs. Conventional Fire Cable
In life safety systems, such as fire detection and alarm systems, the cable specification

Which cable can withstand high industrial temperatures?
Understand which cables can withstand high temperatures, which materials and thermal classes to evaluate, and how to specify safety for critical industrial processes.

Why do cables fail in industrial applications?
Understand why cables fail in the field and how specification, installation, and maintenance preserve reliability in critical industrial assets.
Knowledge Academy: Technical information, standards and applications

Tables and Codes for Thermocouples
International Color Code for Compensation and Extension Cables and Wires - Cable Code - Error Limit Table

NBR 5410 Sizing Tables
DOWNLOAD NBR 5410 DIMENSIONING TABLES Explanation With the aim of offering a practical tool to assist in the work of

Color code tables
Color code according to DIN 47100 No. Colour Short Form 1 WHITE WH 2 BROWN BN 3

TABLE AND GUIDELINES AWG X METRIC CONVERSION (mm²)
Unveiling the AWG Standard: A Technical Guide for Professionals and Enthusiasts – American Wire Gauge (AWG) to Metric (mm²) Conversion
Questions? Send a message to the expert.
Access to cutting-edge scientific information is the fuel for innovation. These are the databases, journals, and repositories that our R&D team uses to stay at the forefront of global technical and scientific knowledge.
Databases, Repositories and Search Engines:
- IEEE Xplore Digital Library: The most crucial digital library for electrical and computer engineering. IEEE
- ACM Digital Library: A reference for the field of computer science and information technology. ACM
- Science Direct: Extensive collection of scientific publications and books from the publisher Elsevier. SCIENCE DIRECT
- Scopus: The largest database of abstracts and citations from peer-reviewed literature. scopus
- CAPES Journal Portal: It provides access to international scientific output for the teaching and research community in Brazil. CAPES
- Google Scholar Search tool focused on academic literature. GOOGLE SCHOLAR
- Brazilian Digital Library of Theses and Dissertations (BDTD): Repository of scientific output from Brazilian teaching and research institutions. BDTD
- Directory of Open Access Journals (DOAJ): A directory of high-quality open access journals. DOAJ
Prominent Scientific Periodicals and Journals:
- Naval, Offshore and Petroleum Engineering:
- Ocean Engineering (Elsevier)
- Journal of Ship Research (SNAME)
- Journal of Petroleum Science and Engineering (Elsevier)
- Journal of Marine Science and Engineering (MDPI)
- Journal of the Brazilian Society of Naval Engineering (SOBENA)
- Electrical, Electronic and Telecommunications Engineering:
Products

Profibus DP DeepSea® Armed SHF2
Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; 1x2x0,64; SHF2; Flame retardant: IEC 60332-1-2; violet; 8 mm

MariTimus® Single-Core Marine Power and Control Cable 0,6/1 kV XLPE/SHF1 (LSOH) Armored and Flame Retardant
Maritimus® Single-Core Naval Power and Control Cable; Armored; Max. 300,00 mm²; 0,6/1 kV; 1 conductor; XLPE / SHF1; Flame Retardant; +90°C; IEC 60092

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Fire Resistant IEC 60331
Maritimus® Single-Core Marine Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Armored and Fire Resistant IEC 60331
Maritimus® Armored Multicore Naval Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331