SHF1 and SHF2 covers according to NEK-606

The outer sheath is a critical component for the integrity and longevity of a cable, acting as the first line of defense against physical and environmental aggressions. It protects the internal components against extreme temperature variations, exposure to oils and chemicals, hydrostatic pressure, UV radiation, saline moisture, and abrasive mud.
The norm NEK TS 606:2016 It is the reference for low and high voltage cables in offshore installations, and defines stringent requirements for sheathing materials, classifying them mainly into two types: SHF1 e SHF2.
| Compound Type (NEK 606) | Chemical Characteristics | Main Resistance | Recommended Application |
|---|---|---|---|
| SHF1 | Thermoplastic (Halogen-Free / LSZH) | Low smoke during fires. Lower cost. | Control rooms, accommodations, interior areas of ships and platforms. |
| SHF2 | Cross-linked Elastomer (Thermoset) | Oil and Mud (Mud Resistant)High mechanical strength. | Open deck, drilling areas, exposure to weather and hydrocarbons. |
| PVC (Common) | Halogenated Thermoplastic | Does not meet NEK 606 (Emits toxic fumes). | For onshore industrial use (not recommended for offshore use). |
Technical Definitions
- SHF1 (Sheath, Halogen-Free, Thermoplastic): A halogen-free thermoplastic compound with low smoke and toxic gas emissions in case of fire (LSZH – Low Smoke Zero Halogen). Being a thermoplastic, it softens when heated and hardens when cooled, without chemical alteration.
- SHF2 (Sheath, Halogen-Free, Cross-linked Thermoset): A cross-linked thermoset (or elastomeric) compound, also halogen-free and with LSZH characteristics. The cross-linking process creates permanent chemical bonds, giving the material superior thermal stability and greater resistance to aggressive fluids and deformation under heat.
Key Differences and Strategic Applications
The choice between SHF1 and SHF2 is determined by the requirements of the application and the installation environment.
- SHF1: It is characterized by its greater hardness and rigidity. It is the ideal choice for controlled indoor environments where human safety and the protection of electronic equipment are priorities.
- Typical Applications: Data centers, control rooms, high-density commercial buildings (hotels, hospitals), and public transportation systems such as subways.
- SHF2: It stands out for its superior flexibility, robustness, and resistance to harsh environments. Its thermosetting nature makes it resilient to oils, mud, chemicals, and temperature variations.
- Typical Applications: Oil and gas platforms (offshore), vessels, shipyards, and industrial environments exposed to inclement weather and hydrocarbon contamination.
Comparative Analysis of Properties (According to IEC Standards)
The table below details the performance differences between the compounds, according to the tests required by the IEC standards, which serve as the basis for NEK 606.
| Title: Comparative Analysis of Exterior Coatings: SHF1 vs. SHF2 under the NEK 606 Standard | Requirements for SHF1 | Requirements for SHF2 |
| Type of material | Halogen-free thermoplastic | Elastomeric or thermoset crosslinked, halogen-free |
| Hot Oil Resistance (IEC 60811-404) | No specific requirements. | 100°C for 24 hours: • Maximum variation in traction: ±40% • Maximum variation in elongation: ±40% |
| Hot Set Test (IEC 60811-507) | Not applicable to thermoplastics. | 200°C for 15 min. (under load of 20N/mm²): • Maximum elongation under load: 175% • Maximum permanent deformation after cooling: 25% |
| High Temperature Pressure Test (IEC 60811-508) | 80°C (4-6h under load): • Maximum allowable deformation: 50% | No specific requirements (covered by the Hot Set Test). |
| Thermal Shock Test (IEC 60811-509) | Required at 150°C for 1 hour (without cracks). | No specific requirements. |
| Ozone resistance (IEC 60811-403) | No specific requirements. | 25°C for 24 hours: • Resistant to ozone concentrations of 0.025-0.030%. |
Looking for cables with this specification? Check out our products:
1. Maritimus® Line (IEC 60092 Standard)
The standard choice for commercial and naval vessels. This line strictly adheres to the series standards. IEC 60092, ensuring safety and performance in fixed onboard installations.
Applications: Lighting, control, instrumentation and general power on ships.
Highlights: Fire-resistant (IEC 60331) and flame-retardant options.
Available Models: Instrumentation, Power and Control Cables (Fire Resistant and Flame Retardant), as well as Medium Voltage options.
👉 [Access the Maritimus® Line Technical Catalog here.]
2. Deepsea® Line (Offshore / NEK-606 SHF2)
Designed for the most aggressive conditions of the offshore and oil & gas industry. These cables have a protective covering. SHF2, offering superior protection against Mud (Mud Resistant), oils and mechanical abrasion.
Applications: Oil platforms, FPSOs, areas with hydrocarbon deposits, and drilling mud.
Highlights: Extreme chemical and mechanical resistance (SHF2).
Available Models: Instrumentation, Medium Voltage and Power Cables (all with SHF2 mud protection).
👉 [Access the Deepsea® Product Line Technical Catalog here.]
3. Hydrocore® Line (Subsea / Polyurethane PUR)
The high-performance mechanical line. Manufactured with a coating in Polyurethane (PUR)These cables offer maximum resistance to tearing, cutting, and hydrolysis, making them ideal for humid and dynamic environments.
Applications: Deck equipment, naval robotics, and areas subject to high mechanical stress and constant humidity.
Highlights: Polyurethane (PUR) ensures superior durability in dynamic (mobile use) and submerged environments.
Available Models: Instrumentation and Power/Control (Fire Resistant and Flame Retardant with PUR sheath).
👉 [Access the Hydrocore® Product Line Technical Catalog here.]
Frequently Asked Questions about NEK 606 Covers (SHF1 and SHF2)
Question 1: What does the acronym SHF1 mean? Resposta: SHF1 stands for "Sheath Halogen Free 1". It is a halogen-free thermoplastic compound, required by the NEK 606 standard for cables installed in internal areas of vessels and platforms. Its main function is to ensure safety: in case of fire, it does not emit toxic or corrosive gases or dense smoke.
Question 2: Can I use SHF1 cable outdoors (on deck)? Resposta: Although the SHF1 has UV resistance, for harsh outdoor areas in offshore environments, the SHF2 It is the most suitable. SHF2 is a cross-linked material (harder and more resistant) that better withstands the attack of oils, greases, and the mechanical abrasion typical of the deck.
Question 3: Is the SHF1 cable mud resistant? Resposta: Generally not. Resistance to drilling mud (Mud Resistant) is a typical characteristic of the compounds. SHF2If your project requires a "Mud Resistant" specification according to NEK 606, you should choose cables from our line. Deepsea (SHF2).
SHF1 and SHF2 covers according to NEK-606
- 1. INNOVCABLE TECHNICAL RESOURCE CENTER
- 1.1 Application and Installation Guides for Mobile Cables
- 1.2 Calculation and Dimensioning Tools
- 1.3. Specifications and Material Data
- 1.3.1 Codes and Nomenclatures for Naval Cables NEK 606
- 1.3.2 SHF1 AND SHF2 COVERS (NEK 606)
- 1.3.3 RESISTANCE OF INSULATION AND SHEATH MATERIALS
- 1.3.4 Armor Resistance
- 1.3.5 Fire Performance Standards (Fire Performance Cable Standards)
- 1.3.6 Tables of Compensating and Extension Thermocouple Wires and Cables
- 1.4. Glossary and Quick References
- 2. Industry Standards and Regulations
- 3. Innovation and Research Ecosystem
Related Articles

Tables and Codes for Thermocouples
International Color Code for Compensation and Extension Cables and Wires - Cable Code - Error Limit Table

NBR 5410 Sizing Tables
DOWNLOAD NBR 5410 DIMENSIONING TABLES Explanation With the aim of offering a practical tool to assist in the work of

Color code tables
Color code according to DIN 47100 No. Colour Short Form 1 WHITE WH 2 BROWN BN 3

TABLE AND GUIDELINES AWG X METRIC CONVERSION (mm²)
Unveiling the AWG Standard: A Technical Guide for Professionals and Enthusiasts – American Wire Gauge (AWG) to Metric (mm²) Conversion

STANDARD
British cable standards BS4737-3.30:1986 Intrusion alarm systems. Specification for PVC insulated cables for interconnect wiring.

RESISTANCE OF INSULATION AND SHEATH MATERIALS, COMPARISON OF PROPERTIES
Compound Properties PVC HDPE CPE Polyethylene Cellular Polypropylene Nylon PUR Oxidation Resistance E E E E E

ARMOUR RESISTANCE
BS6480 Shielding Resistance Cable: Conductor, conductor sheath, shielding resistance and percentage conductivity of 2 cables,

Minimum permissible bending radius: according to DIN VDE 0298 part 3
Minimum permissible bending radius according to DIN VDE 0298 part 3. Rated voltage up to 0,6 / 1 kV.
Questions? Send a message to the specialist.
Products

Profibus DP DeepSea® Armed SHF2
Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; 1x2x0,64; SHF2; Flame retardant: IEC 60332-1-2; violet; 8 mm

MariTimus® Single-Core Marine Power and Control Cable 0,6/1 kV XLPE/SHF1 (LSOH) Armored and Flame Retardant
Maritimus® Single-Core Naval Power and Control Cable; Armored; Max. 300,00 mm²; 0,6/1 kV; 1 conductor; XLPE / SHF1; Flame Retardant; +90°C; IEC 60092

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Fire Resistant IEC 60331
Maritimus® Single-Core Marine Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Armored and Fire Resistant IEC 60331
Maritimus® Armored Multicore Naval Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331