Naval Armed Corporal

BS6480 Shielded Resistance Cable: Conductor, conductor sheath, shield resistance and percentage conductivity of 2, 3 and 4 core cables conforming to BS6480 standard (copper conductors). Voltage rating 600/1000 Volts – Resistance Values

LINK TO TABLE: BS6480 Shielding Resistance Cable: Conductor, conductor sheath, shielding resistance and percentage conductivity of 2, 3 and 4 core cables conforming to BS6480 standard (copper conductors). Voltage rating 600/1000 Volts – Resistance Values

TABLE BEC 114 Armature resistance and short-circuit ratings of conductors for 600/1000 V power and control cables according to BS6883, IEC60331 and IEC60332

LINK TO TABLE: TABLE BEC 114 Armature resistance and short-circuit ratings of conductors for 600/1000 V power and control cables according to BS6883, IEC60331 and IEC60332

Type 21 armored resistance cable, BS6708 conductor, armor resistance and percentage conductivity of 4-core cables conforming to BS6708, type 21.

LINK TO TABLE: Type 21 armored resistance cable, BS6708 conductor, armor resistance and percentage conductivity of 4-core cables conforming to BS6708, type 21

EEMUA cable conductor with armor resistance, conductor protection, armor resistance and percentage conductivity of 2, 3 and 4 core cables conforming to class EEMUA133 600/1000 Volts.

LINK TO TABLE: EEMUA cable conductor with armor resistance, conductor protection, armor resistance and percentage conductivity of 2, 3 and 4 core cables conforming to class EEMUA133 600/1000 Volts.

BS6724 Conductor Armor Resistance, Armor Resistance and Percentage Conductivity of 2, 3 and 4 Core Cables. PVC according to BS6346, XLPE according to BS5467 or BS6724 (Copper Conductors)

LINK TO TABLE: BS6724 Conductor Armature Resistance, Armor Resistance and Percentage Conductivity of 2, 3 and 4 Core Cables. PVC according to BS6346, XLPE according to BS5467 or BS6724 (Copper Conductors)

BS5467 Conductor Armor Resistance, Armor Resistance and Percentage Conductivity of 2, 3 and 4 Core Cables. PVC according to BS6346, XLPE according to BS5467 or BS6724 (Copper Conductors)

LINK TO TABLE: BS5467 Conductor Armature Resistance, Armor Resistance and Percentage Conductivity of 2, 3 and 4 Core Cables. PVC according to BS6346, XLPE according to BS5467 or BS6724 (Copper Conductors)

ARMOUR RESISTANCE

Related Articles

STANDARD

British cable standards BS4737-3.30:1986 Intrusion alarm systems. Specification for PVC insulated cables for interconnect wiring.

Read more "

Questions? Send a message to the specialist.

Products

Profibus DP Black double shielded cable, SHF2 DeepSea crossbar
Instrumentation cables - flame retardant SHF2

Profibus DP DeepSea® Armed SHF2

Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; 1x2x0,64; SHF2; Flame retardant: IEC 60332-1-2; violet; 8 mm

Read more "