
Tables and Codes for Thermocouples

- INTERNATIONAL COLOR CODE FOR COMPENSATION AND EXTENSION CABLES AND WIRES

- CABLE CODES



- Table of Error Limits according to IEC 584-3

Tables and Codes for Thermocouples
- 1. INNOVCABLE TECHNICAL RESOURCE CENTER
- 1.1 Application and Installation Guides for Mobile Cables
- 1.2 Calculation and Dimensioning Tools
- 1.3. Specifications and Material Data
- 1.3.1 Codes and Nomenclatures for Naval Cables NEK 606
- 1.3.2 SHF1 AND SHF2 COVERS (NEK 606)
- 1.3.3 RESISTANCE OF INSULATION AND SHEATH MATERIALS
- 1.3.4 Armor Resistance
- 1.3.5 Fire Performance Standards (Fire Performance Cable Standards)
- 1.3.6 Tables of Compensating and Extension Thermocouple Wires and Cables
- 1.4. Glossary and Quick References
- 2. Industry Standards and Regulations
- 3. Innovation and Research Ecosystem
Related Articles

NBR 5410 Sizing Tables
DOWNLOAD NBR 5410 DIMENSIONING TABLES Explanation With the aim of offering a practical tool to assist in the work of

Color code tables
Color code according to DIN 47100 No. Colour Short Form 1 WHITE WH 2 BROWN BN 3

TABLE AND GUIDELINES AWG X METRIC CONVERSION (mm²)
Unveiling the AWG Standard: A Technical Guide for Professionals and Enthusiasts – American Wire Gauge (AWG) to Metric (mm²) Conversion

STANDARD
British cable standards BS4737-3.30:1986 Intrusion alarm systems. Specification for PVC insulated cables for interconnect wiring.

RESISTANCE OF INSULATION AND SHEATH MATERIALS, COMPARISON OF PROPERTIES
Compound Properties PVC HDPE CPE Polyethylene Cellular Polypropylene Nylon PUR Oxidation Resistance E E E E E

ARMOUR RESISTANCE
BS6480 Shielding Resistance Cable: Conductor, conductor sheath, shielding resistance and percentage conductivity of 2 cables,

Minimum permissible bending radius: according to DIN VDE 0298 part 3
Minimum permissible bending radius according to DIN VDE 0298 part 3. Rated voltage up to 0,6 / 1 kV.

Radius of Curvature
Minimum Bending Radius in Mobile Cables: The Boundary Between Performance and Premature Failure
Questions? Send a message to the specialist.
Products

Profibus DP DeepSea® Armed SHF2
Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; 1x2x0,64; SHF2; Flame retardant: IEC 60332-1-2; violet; 8 mm

MariTimus® Single-Core Marine Power and Control Cable 0,6/1 kV XLPE/SHF1 (LSOH) Armored and Flame Retardant
Maritimus® Single-Core Naval Power and Control Cable; Armored; Max. 300,00 mm²; 0,6/1 kV; 1 conductor; XLPE / SHF1; Flame Retardant; +90°C; IEC 60092

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Fire Resistant IEC 60331
Maritimus® Single-Core Marine Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Armored and Fire Resistant IEC 60331
Maritimus® Armored Multicore Naval Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331