Learn how to specify encoder cable based on signal strength, distance, bending, and environment, reducing noise, reading errors, and downtime in field automation.
How to Specify Cable for Encoder Without Errors

A seemingly correct encoder cable can become the point of failure for a critical axis. Loss of pulses, position error, intermittent drive alarms, and speed instability are rarely isolated encoder problems. In many cases, the origin lies in inadequate cable selection, poorly applied shielding, installation near interference sources, or mechanical incompatibility with the machine's movement.

In industrial automation, the cable is part of the measurement system. It needs to preserve the integrity of the signal between the encoder and the control, withstand the operating environment, and maintain its performance over thousands or millions of cycles. Therefore, the specification should not be limited to the number of conductors and the nominal gauge.

How to specify a cable for an encoder

The specification begins with the encoder technology and the communication interface. Incremental encoders can work with A, B, and Z signals, usually with their complementary signals. Absolute encoders, on the other hand, can use protocols such as SSI, BiSS, EnDat, Hiperface, or proprietary interfaces. Each architecture requires a specific combination of pairs, power conductors, shielding, and electrical characteristics.

The first step is to consult the manufacturer's manual for the encoder, servo drive, or PLC. The document should indicate the pinout, supply voltage, current, output type, maximum recommended distance, and, when applicable, the characteristic impedance. A generic cable may even work during commissioning, but may exhibit instability when the equipment enters steady state, especially in environments with frequency inverters and high switched currents.

It is also necessary to separate the signal and power supply circuits. In a well-designed solution, differential signals travel along individual twisted pairs, while the power conductors supply the encoder according to the permissible current and voltage drop. This construction reduces coupling between circuits and improves electromagnetic immunity.

Differential signaling requires twisted pairs.

For differential interfaces, such as RS-422 and complementary A/A¯, B/B¯, and Z/Z¯ signals, each channel must use a twisted pair. The twisting causes external interference to affect both conductors similarly. In the differential receiver, this common noise tends to be rejected, preserving the reading of the useful signal.

However, simply having twisted pairs in the cable is not enough. It is necessary to ensure that each pair corresponds to its complementary signal and that the connector assembly maintains this logic up to the termination point. Excessively opening the pairs, improvising splices, or reversing conductors in the field compromises the protection obtained by the cable construction.

In longer distance or higher frequency links, capacitance, electrical resistance, and pair geometry become crucial. High capacitance can round pulse edges and reduce the communication margin. Excessive resistance, in turn, increases signal attenuation and voltage drop in the power supply. The correct selection depends on the protocol, length, and transmission speed, not on a single rule for all applications.

Shielding on encoder cables: what to consider

Shielding is one of the main resources against electromagnetic noise, but it only delivers results when selected and grounded correctly. Machines with servomotors, frequency inverters, contactors, switched-mode power supplies, electric welding, or nearby power cables require extra attention to electromagnetic compatibility.

Collective shielding protects the entire set of conductors. When there are individually shielded pairs, the separation between channels is greater, which can be advantageous for more sensitive protocols or installations with high interference. The choice between braid, metallized tape, or a combination of both should consider the shielding coverage, the required flexibility, the predominant noise frequency, and the need for electrical continuity in motion.

Shield grounding cannot be treated as a mere installation detail. In industrial applications, a 360-degree connection at the cable gland or connector often offers better high-frequency performance than a long, insulated drain wire. Even so, the choice of grounding at one or both ends depends on the equipment architecture, manufacturer recommendations, and plant equipotentiality conditions. There are cases where an inadequate solution creates currents through the shield and introduces new problems.

Keeping the encoder cable away from power cables is equally important. Whenever there is unavoidable crossing, perpendicular orientation reduces the coupling distance. Sharing cable trays, conduits, or cable routes with inverter outputs is a decision that should be technically evaluated, not a matter of mounting convenience.

Movement, bending, and twisting define service life.

A stationary machine and a six-axis robot impose completely different stresses on the same electrical circuit. For fixed installations, priority may be given to shielding, bending radius, chemical resistance, and regulatory compliance. For cable carriers, reels, gantries, and moving axes, mechanical construction becomes as relevant as electrical performance.

In continuous bending applications , the cable must have flexible conductors, appropriate stranding, compatible insulation materials, and an internal geometry that limits displacement between the elements. The outer sheath must resist abrasion and contact with oil, grease, cutting fluid, or cleaning agents present in the process.

In robotics, torsion is the critical factor. A conveyor belt cable is not automatically suitable for torsion, just as a common flexible cable should not be assumed to be suitable for repetitive cycles. The specification must provide the travel, bending radius, speed, acceleration, expected number of cycles, and angle of twist per meter. This data guides the design and prevents internal ruptures that only appear after months of production.

Industrial environment and project compliance

Temperature, humidity, presence of oil, salt spray, UV radiation, abrasive dust, and fire risk directly influence material selection. In naval, offshore, mining, steelmaking, or chemical processing areas , standard coatings may not meet operational requirements. The coating must be compatible with the environment and the expected service life, without compromising flexibility or ease of installation.

Requirements for low smoke emission, absence of halogens, flame retardancy, oil resistance, and compliance with specific standards should be included from the initial technical request. It is unproductive to define these conditions only after equipment approval, as changes to routing, connections, or deadlines can increase project costs.

The documentation should also reflect the criticality of the application. Identification of conductors, construction design, electrical data, materials, traceability, and inspection criteria facilitate maintenance, replacement, and standardization of machines. For OEMs and integrators, this attention to detail reduces variations between batches and simplifies the replication of panels and cable assemblies.

Data that should accompany the technical consultation.

An efficient consultation avoids specifications based on approximations. Provide the encoder and drive model, communication protocol, pinout or electrical diagram, total circuit distance, and installation type. Also include whether the cable will be fixed, on a conveyor belt, subject to twisting, exposed to oil, outdoors, or installed in an area with strong electromagnetic interference.

When movement is involved, kinematic data is essential: minimum available radius, travel, speed, acceleration, expected cycles, and cable accommodation method. It is also important to specify the connector type, the need for pre-assembly, the quantity per machine, and any regulatory requirements from the end customer. These elements transform a component purchase into an applicable engineering specification.

Innovcable develops special cables according to the electrical, mechanical, and environmental needs of each project. For critical applications, custom manufacturing allows combining twisted pairs, shields, power conductors, sheath materials, and bending requirements into a solution consistent with the machine and the industrial process.

Recurring flaws that the specification prevents

A common mistake is selecting cables solely based on the number of conductors. Two cables with the same number of conductors can exhibit very different behaviors in terms of noise, capacitance, bending resistance, and durability. Another frequent problem is using control cable for encoder signals in an environment with a frequency inverter, ignoring the need for twisted pairs and adequate shielding.

Also deserving attention are unplanned splices, connectors lacking shielding continuity, bending radii below the recommended level, and cable glands that do not make proper contact with the shielding. The fault may not appear in static tests, but may emerge during movement cycles, load peaks, or simultaneous motor starts.

A good practice is to validate the cable, connector, grounding, and installation route before the machine is finally released for use. Measuring continuity, insulation, pair position, shielding integrity, and signal quality during operation helps identify deviations when they are still simple to correct.

The correct cable isn't necessarily the highest specification available. It's the one designed to preserve the signal, withstand the actual installation, and offer a lifespan compatible with the axis's criticality. When application data is incorporated into engineering from the start, the encoder ceases to be a recurring source of downtime and begins to deliver the precision for which it was chosen.

How to Specify Cable for Encoder Without Errors

Related Articles

Knowledge Academy: Technical information, standards and applications

Questions? Send a message to the expert.

Access to cutting-edge scientific information is the fuel for innovation. These are the databases, journals, and repositories that our R&D team uses to stay at the forefront of global technical and scientific knowledge.

Databases, Repositories and Search Engines:

  • IEEE Xplore Digital Library: The most crucial digital library for electrical and computer engineering. IEEE
  • ACM Digital Library: A reference for the field of computer science and information technology. ACM
  • Science Direct: Extensive collection of scientific publications and books from the publisher Elsevier. SCIENCE DIRECT
  • Scopus: The largest database of abstracts and citations from peer-reviewed literature. scopus
  • CAPES Journal Portal: It provides access to international scientific output for the teaching and research community in Brazil. CAPES
  • Google Scholar Search tool focused on academic literature. GOOGLE SCHOLAR
  • Brazilian Digital Library of Theses and Dissertations (BDTD): Repository of scientific output from Brazilian teaching and research institutions. BDTD
  • Directory of Open Access Journals (DOAJ): A directory of high-quality open access journals. DOAJ

Prominent Scientific Periodicals and Journals:

  • Naval, Offshore and Petroleum Engineering:
    • Ocean Engineering (Elsevier)
    • Journal of Ship Research (SNAME)
    • Journal of Petroleum Science and Engineering (Elsevier)
    • Journal of Marine Science and Engineering (MDPI)
    • Journal of the Brazilian Society of Naval Engineering (SOBENA)
  • Electrical, Electronic and Telecommunications Engineering:
    • IEEE Transactions on Power Systems (Available via IEEE Xplore)
    • IEEE Transactions on Power Delivery (Available via IEEE Xplore)
    • IEEE Transactions on Communications (Available via IEEE Xplore)
    • Telecommunications Magazine (Inatel): INATEL
    • Control & Automation Magazine (SBA): SBA

Products

Profibus DP Black double shielded cable, SHF2 DeepSea crossbar
Instrumentation cables - flame retardant SHF2

Profibus DP DeepSea® Armed SHF2

Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; 1x2x0,64; SHF2; Flame retardant: IEC 60332-1-2; violet; 8 mm

Read more "