Power cable for airport runway lighting; 5 kV; 1 to 19 conductors; Max. 4 to 12 AWG; XLPE / PVC; 90°C

FAA L-824 C 600V Airport Lighting Auxiliary Cable

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

FAA L-824 Airport Cable Car: The Ultimate Choice for Aviation SafetyDeveloped to meet the lighting requirements of airports, it is the solution for runways, control systems, and vital installations. Its superior construction ensures maximum performance and reliability in underground installations, where failure is not an option.
  • Certified Security: Fully compliant with FAA L-824 C standard, ensuring maximum operational safety for circuits.
  • Superior Durability: XLPE or EPR/B insulation, with high resistance to abrasion, moisture and heat.
  • Versatile Installation: Perfect for direct burial, conduit routing, or use in cable trays, making any project easier.
  • High Energy Performance: Bare copper conductors that ensure excellent conductivity and maximum efficiency.
  • Confidence in Extreme Climates: Stable operation in temperatures ranging from -40°C to +90°C, essential for critical and continuous missions.
PRODUCT DESIGN
  • Conductor: Bare stranded copper according to ASTM B
  • Insulation: XLPE or EPR/B
  • Outer Sheath: PVC (for multi-conductor models only).
  • Manufactured in black RAL 9005.
  • Nominal voltage: 600 V
  • Identification: INNOVCABLE X AWG 600V EPR/B 90 C FAA-L824, TYPE C
  • Applicable Specifications: FAA AC150/5345-7F, NEMA WC71, FAA L-824 C Specification, ICEA S-95-658
  • Applications: The airport lighting cable is constructed for underground use in accordance with the requirements of (FAA) L-824 C for airport lighting circuits FAA AC150/5345-7F.
  • Bare annealed copper conductors, class B, insulated with XLPE or EPR/B resistant to abrasion, moisture and heat.
  • Airport lighting cable is primarily used for series lighting circuits for runways, control systems, and other multi-functional facilities.
  • It can be used for direct burial, conduit, or cable trays.
  • Maximum Conductor Temperature: Fixed Operating Temperature: -40°C to +90°C
  • Maximum conductor temperature during normal operation: ≤90°C
DETAILS

Benefits

  • Superior Resistance: XLPE or EPR/B insulation, resistant to moisture, abrasion and heat.
  • High Durability: Developed specifically for underground use and direct burial.
  • Wide Temperature Range: Reliable operation in conditions ranging from -40°C to +90°C.
  • Compliance Assured: Meets the stringent requirements of FAA standard L-824 C.
  • Versatile Installation: Flexible for mounting in conduits, cable trays, or directly in the ground.
  • Guaranteed Conductivity: Braided bare copper conductors for maximum electrical efficiency.
  • Operational Safety: Rated voltage of 600V, ideal for lighting and control circuits.
  • Certified Quality: Manufactured in accordance with NEMA WC71 and ICEA S-95-658 specifications.
  • Rugged for Critical Environments: Construction designed to withstand the harsh conditions of airports.
  • Stable Performance: It ensures the integrity and reliability of signaling systems.

Applications

  • Track Lighting: Power supply for serial circuits used in runway and takeoff lighting.
  • Taxiway Signage: Essential for aircraft taxiway lighting systems.
  • Airport Control Systems: Used in control and monitoring circuits at airport facilities.
  • Underground Infrastructure: Ideal for underground electrical networks installed in yards and airfields.
  • Power and Signal Circuits: For distribution in multi-functional facilities within the airport area.
  • Expansion Projects: Used in new construction and in the modernization of lighting systems.
  • Installation in Conduits: Perfect for routing through ducts for enhanced mechanical protection.
  • Direct Burial Applications: It optimizes costs and installation time by being buried directly.
  • Networks in Cable Trays: Suitable for organizing cable distribution in technical conduits.
  • Visual Beacon Systems: Power for approach lights, bedside lights and other aids.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typeCable for airport lighting, FAA type L-824 C.
Electrical Parameters
Nominal Voltage600 V
Product Design
Conductor MaterialBare braided copper.
Driver DesignBare annealed copper, class B, according to ASTM B.
Number of Filaments7 strands.
Base Material for Vein IsolationXLPE or EPR/B.
Base Material for the External CoveringPVC (applicable only to multiconductor versions).
Cover ColorBlack (RAL 9005).
Marking on the CableINNOVCABLE X AWG 600V EPR/B 90 C FAA-L824, TYPE C.
Product characteristics
Application AreaUnderground use for airport lighting circuits (runways, control systems). Suitable for direct burial, installation in conduits or raceways.
Temperature, fixed installation-40 °C to +90 °C.
Maximum temperature in the driver+90 °C.
Abrasion ResistantYes.
Moisture ResistantYes.
Heat ResistantYes.
Applicable Standards
FAA L-824 CMain product specification.
FAA AC150/5345-7FRequirements for airport lighting circuits.
NEMA WC71Standard for power cables.
ICEA S-95-658Standard for power cables with extruded insulation.
ASTM BStandard for copper conductors.
DIMENSIONAL TABLE
NUMBER OF ROADSNominal Section AWGNUMBER OF WIRESNOMINAL INSULATION THICKNESS mmNOMINAL COVER THICKNESS mmNOMINAL OUTER DIAMETER mm
NOMINAL WEIGHT kg/km
11271,14-4,6246
11071,14-5,2161
1871,52-6,76101
1671,52-7,72152
1471,52-8,94231
21270,761,1410,41146
21070,761,1411,56199
2871,141,5215,37323
2671,141,5217,4446
2471,521,5219,81632
31270,761,1411,05187
31070,761,1412,19259
3871,141,5216,38437
3671,141,5218,42610
3471,142,0321,97908
41270,761,1412,07222
41070,761,5214,22350
4871,141,5217,91548
4671,141,5220,19772
4471,142,0324,131165
51270,761,1413,08292
51070,761,5215,49405
61270,761,5215,24357
61070,761,5216,89495
71270,761,5215,24379
71070,761,5216,89534
81270,761,5216,38430
81070,761,5218,29604
91270,761,5217,65479
91070,761,5219,69707
101270,761,5218,42539
101070,761,5220,57762
111270,761,5218,92594
111070,762,0322,1878
121270,761,5219,43631
121070,762,0322,61933
131270,761,5220,07662
131070,762,0323,5985
141270,761,5220,83708
141070,762,0324,261053
151270,761,5222,35793
151070,762,0324,891119
161270,761,5222,99839
161070,762,0325,651186
171270,761,5223,62902
171070,762,0326,291275
181270,761,5224,26946
181070,762,0326,921342
191270,761,5224,26970
191070,762,0326,921381
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.