Power cable for airport lighting; Shielded; 5 kV; 1 conductor; AWG/mm²; XLPE / PVC – PE; 90°C
FAA L-824 C Shielded 5kV Airport Lighting Auxiliary Cable
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Maximum Operational Safety: Its special shielding with copper tape protects the system against interference, ensuring a stable signal.
- Robust and Durable Construction: It features XLPE insulation that is resistant to abrasion, moisture, heat, and high operating temperatures.
- Versatility in Installation: Ideal for underground use, it can be applied by direct burial, installed in conduits or channels.
- Superior Electrical Performance: High-purity copper conductor with a nominal voltage of 5KV for efficient power transmission.
- Trust Certification: Manufactured in full compliance with FAA L-824 C specifications, ensuring maximum quality and suitability.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | INNOVCABLE |
| Product type | Shielded lighting cable for airports, for underground use. |
| Córdoba | FAA L-824 C Armored (Shielded) |
| Electrical Parameters | |
| Nominal Voltage | 5,0 kV |
| Electrical Resistance of the Conductor (DC at 20°C) | 3.08 Ω/km (6mm²); 2.144 Ω/km (8 AWG); 1.348 Ω/km (6 AWG); 0.8481 Ω/km (4 AWG) |
| Product Design | |
| Conductor Material | Bare copper, braided and annealed. |
| Driver Class | Class B. |
| Inner Semiconductor Layer | Extruded semiconductor layer. |
| Base Material for Insulation | Cross-linked polyethylene (XLPE) or EPR/B. |
| Outer Semiconductor Layer | Semiconductor tape applied helically or extruded. |
| shielding | Copper tape or tinned copper mesh. |
| Base Material for the External Covering | PVC. Other options such as PE/XLPE available upon request. |
| Cover Color | Black (RAL 9005). |
| Available Gauges | From #8 AWG to #4 AWG. |
| Printed Identification | INNOVCABLE |
| Product characteristics | |
| Application Area | Serial lighting circuits for airport runways, control systems and other multi-functional installations. |
| Installation Mode | Direct burial, in conduit or channels. |
| Normal Operating Temperature | + 90 ° C |
| Emergency Operating Temperature | + 130 ° C |
| Short-Circuit Temperature | 250 ° C |
| Abrasion Resistant | Yes |
| Moisture Resistant | Yes |
| Heat Resistant | Yes |
| Dimensional Data (Approximate Values) | |
| Outer Diameter of the Conductor | 3.69mm (8AWG); 4.68mm (6AWG); 5.88mm (4 AWG) |
| Nominal Insulation Thickness | 2.3 mm |
| External Diameter over Insulation | 8.29mm (8AWG); 9.28mm (6AWG); 10.48mm (4 AWG) |
| Nominal Coating Thickness | 0.76mm (8AWG); 0.78mm (6AWG); 1.14mm (4 AWG) |
| Final Outside Diameter | 14.3mm (8AWG); 15.4mm (6AWG); 17.0mm (4 AWG) |
| Copper Weight (kg/km) | 298 (8AWG); 366 (6AWG); 513 (4 AWG) |
| Applicable Standards | |
| FAA Specification | FAA L-824 C |
| FAA Advisory Circular | FAA AC 150/5345-7E; FAA AC 150/5345-7F |
| ICEA | S-93-639 |
| NOT MY | WC74 |
| Size mm2/AWG | Conductor - Structure No. | Conductor - Approx. Diameter mm | Insulation - Nominal Thickness mm | Insulation - Approx. Diameter mm | Sheath - Nominal Thickness mm | Sheath - Approx. Diameter mm | Approximate Weight CU kg/km | Maximum DC Conductor Resistance at 20°C Ω/km |
| 1x6mm2 | 7/19 | 3.12 | 2.3 | 7.72 | 1.2 | 11 | 180 | 03.08 |
| 1x8AWG | 7/19 | 3.69 | 2.3 | 8.29 | 0.76 | 14.3 | 298 | 2.144 |
| 1x6AWG | 7/19 | 4.68 | 2.3 | 9.28 | 0.76 | 15.4 | 366 | 1.348 |
| 1x4AWG | 7/19 | 5.88 | 2.3 | 10.48 | 1.14 | 17 | 513 | 8.481 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.