Power cable for airport lighting; BFC shielded; 6/6 kV; 1 conductor; 10 mm²; EPR-B (XLPE) / PVC; 90°C

Airport Lighting Auxiliary Beacon Cable NBR 7732 3,6/6kv SHIELDED BFC

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Armored Copper Tape Aerial Marking Cable: Safety and Performance for RunwaysEssential for runway lighting, our cable ensures maximum reliability and continuous operation. It's the ultimate solution for airports seeking efficiency and durability.
  • High Operational Safety: Superior protection against moisture, UV rays and weather, ensuring the integrity of the system.
  • Simple and Quick Installation: High driver flexibility (class 5) which facilitates handling and optimizes time.
  • Exceptional Durability: Designed for a long service life, reducing costs associated with replacements and corrective maintenance.
  • Reliable Electrical Performance: It ensures a stable power supply for lighting systems, which is crucial in critical operations.
  • Assured Technical Standard: Manufactured entirely in accordance with NBR 7732, guaranteeing its highest quality.
PRODUCT DESIGN
  • Conductor: Bare electrolytic copper wires, soft temper, class 5 stranding.
  • Insulation: Thermosetting compound (HEPR) 90°C.
  • Intermediate layer: Thermoplastic compound (PVC)
  • Shielding: Copper tape
  • Cover: Thermoplastic compound (PVC) ST2.
  • Applicable Standard: NBR 7732.
  • Insulation Voltage: 3,6/6 kV.
DETAILS

Benefits

  • Superior Durability: Neoprene cover, offering maximum resistance to weathering and UV rays.
  • High Chemical Resistance: A compound immune to degradation by oils, greases, and other chemical agents common in airports.
  • Operational Safety: EPR insulation rated to 90°C, ensuring stable and safe performance under high temperatures.
  • Maximum Reliability: Designed for high voltage (3,6/6 kV) series circuits, ensuring continuous operation.
  • Versatility in Installation: Flexible enough to be buried directly, installed in conduits or trays.
  • Electrical Performance: Electrolytic copper conductor that guarantees excellent conductivity and energy efficiency.
  • Moisture Protection: Robust structure that prevents water penetration, ideal for underground installations.
  • Certified Quality: Manufactured in accordance with NBR 7732 standards, guaranteeing its quality and safety.
  • Reduced Maintenance: The high robustness of the construction materials minimizes repair and replacement costs.
  • Assured Longevity: Developed to withstand the harsh conditions of the airport environment for extended periods.

Applications

  • Runway Lighting: Power supply for the series circuits that activate the center and edge lights of the track.
  • Taxi Lane Signage: Connection of the guide lights (blue) that guide aircraft between the apron and the runways.
  • Marking of Touch Zones: Power is supplied to the lights that mark the precise area for the safe landing of aircraft.
  • Approach Lighting Systems (ALS): Power supply for the approach lights before the runway threshold.
  • Bedside Lighting: Connection of the lights (green and red) that indicate the beginning and end of the runway.
  • Stopway Circuits: Power supply for the stop zone warning lights, used in emergency situations.
  • Airport Infrastructure: Essential in construction, modernization, and expansion projects for beaconing systems.
  • Aircraft Apron Signage: Used in lighting systems for aircraft parking and maneuvering areas.
  • Critical Underground Installations: Ideal for use in ducts and conduits that require maximum protection and reliability.
  • Ramp Visual Systems (PAPI/VASI): Feeding the precision approach indicators on the sides of the runway.
TECHNICAL DATA

 

General information
BrandInnovcable
Product typeAirport Lighting Cable (BFC)
Main StandardNBR 7732
Electrical Parameters
Insulation Voltage3,6 / 6 kV
Product Design
Conductor MaterialBare copper wires, soft temper.
Driver DesignClass 2 string set.
Base Material for Vein IsolationThermosetting compound of ethylene propylene rubber (EPR/A).
Inner cover base materialThermoplastic compound based on polyvinyl chloride (PVC).
shieldingCopper Tape
Base Material for the External CoveringThermoplastic compound based on polyvinyl chloride (PVC).
Cover ColorBlack.
Product characteristics
Application AreaPower supply and distribution circuits in substations, commercial and industrial facilities, and especially in airport runway lighting circuits.
Installation ModeIt can be installed outdoors, in conduits, in trays, or directly buried.
Maximum temperature in the driver (Continuous regime)90 ° C
Maximum temperature in the conductor (Overload regime)130 ° C
Maximum temperature in the conductor (Short-Circuit Regime)250 ° C
Flame retardantYes, it is not a flame propagator.
UV resistantYes, it is resistant to the effects of sunlight.
Applicable Standards
Construction StandardNBR 7732 - Power cables with extruded solid ethylene propylene rubber (EPR) insulation for voltages from 1 kV to 35 kV.

 

DIMENSIONAL TABLE
Nominal cross-section (mm²)Insulation Thickness (mm)Outer layer thickness (mm)Outer diameter (mm)
Approximate weight (kg/km)
103,41,416,3319,8
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.