H05RR-F Cable: The Secure and Flexible Connection for Your Equipment. For light resistance applications.Designed for installations that demand high performance and maximum safety in indoor environments. This cable offers ideal flexibility for connections in compact spaces, ensuring durability and simplified installation for equipment we move around daily.
  • Maximum Performance and Safety: Its robust rubber insulation prevents accidents and short circuits.
  • Flexibility that Makes Life Easier: It adapts perfectly to curves and tight spaces without losing efficiency.
  • Stable and Reliable Connection: Made with special copper, it ensures optimal conductivity and minimal energy loss.
  • Versatility for Everyday Life: Ideal for household appliances, power tools, and office equipment.
  • Durability that's worth the investment: Superior resistance to daily wear and tear, ensuring a long service life.
PRODUCT DESIGN
  • INNOVCABLE H05RR-F – 500V.
  • Conductor material: bare copper wires
  • Driver class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
  • Vein Isolation: CECO™ Special Elastomeric Compound
  • Twisted in layers
  • Outer layer: CEAC™ Special elastomeric compound for light resistance applications.
  • Outer cover in BLACK, RAL 9005
  • Nominal voltage: 300/500V
  • Voltage test: 2000V
  • Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5
  • Insulation resistance: Min. 20 MΩ x Km at 20 °C
DETAILS

Benefits

  • High Flexibility: Class 5 conductors that facilitate installation and handling.
  • Superior Resistance: CECO rubber coating resistant to moisture and weather.
  • Guaranteed Security: Excellent electrical insulation to protect users and equipment.
  • Low Temperature Performance: It retains its properties and flexibility even in cold climates.
  • Simplified Handling: Lightweight material, ideal for equipment that is moved frequently.
  • High Durability: Designed to withstand the low mechanical stresses of daily use.
  • Versatility of Use: Perfect for a wide range of household and portable devices.
  • Technical Compliance: Manufactured in accordance with international standards, ensuring quality.
  • Preventing Dryness: CECO rubber is highly resistant to ozone.
  • Great Value for Money: An economical and reliable solution for low-demand applications.

Applications

  • Home appliances: Power supply for washing machines, refrigerators, and vacuum cleaners.
  • Kitchen Equipment: Connecting mixers, blenders, and microwave ovens.
  • Portable Power Tools: Use in drills, saws and other light hand tools.
  • Office Equipment: Secure connection for computers, monitors, and printers.
  • Lighting Systems: Ideal for assembling lampshades, light fixtures, and light extensions.
  • Electrical Extension Cords: Manufacturing of extension cords for home and office use.
  • Hobby Equipment: Feeding small machines and benchtop tools.
  • Audio and Video Equipment: Power supply for televisions and sound systems.
  • Fans and Heaters: Connecting portable air conditioning units.
  • Temporary Facilities: Perfect for temporary, low-power electrical connections.
TECHNICAL DATA
General information
BrandInnovcable (Reference for Cable H05RR-F)
Product typeCable with rubber coating for light-duty applications.
Harmonized DesignationH05RR-F
Electrical Parameters
Nominal VoltageUo/U: 300/500 V
Test Voltage2 kV
Product Design
Conductor MaterialBare, flexible copper wires.
Driver ClassClass 5 according to DIN VDE 0295 / IEC 60228.
Vein Isolation CECO™ Special Elastomeric Compound with slight resistance.
Exterior Roofing MaterialCEAC™ Special Elastomeric Compound with slight resistance.
Cover ColorBlack.
Road IdentificationColored conductors in accordance with VDE 0293-308 / HD 308 S2.
Includes protective conductor (ground).Available with (G) or without (X) green/yellow protective conductor.
Cable FormatRound
Product characteristics
Application AreaFor connecting household and office appliances, lightweight portable equipment subject to light to medium mechanical stress. Suitable for dry, damp and wet environments.
External useTemporary outdoor use is permitted. It is not suitable for permanent outdoor use or in industrial and agricultural applications.
For continuous bendingYes, for mobile and portable applications. (not constantly moving)
Minimum Bending Radius (fixed installation)4 x outer diameter.
Minimum Radius of Curvature (constant motion)6 to 8 x outside diameter (according to DIN VDE 0298 part 3).
Temperature, fixed installation-40 °C to +1250 °C.
Temperature, constant movement-25 °C to +125 °C.
Maximum temperature in the driver+125 °C.
Flame retardantYes, in accordance with IEC 60332-1-2.
Oil resistantLimited resistance.
UV resistantNot specified as UV resistant for permanent use.
Ozone resistantYes.
Halogen-freeYes.
Applicable Standards
Cable ConstructionEN 50525-2-21, DIN VDE 0285-525-2-21
ConductorIEC 60228, DIN VDE 0295
Road IdentificationHD 308 S2, VDE 0293-308
Flame Non-Propagation TestIEC 60332 1 2
DirectivesLow Voltage Directive 2014/35/EU, RoHS
DIMENSIONAL TABLE
DimensãoExternal Diameter [mm]Weight [kg/km]
X 2 0,755,7 - 7,460
3G 0,756,2 - 8,175
4G 0,756,8 - 8,890
5G 0,758,5 - 8,9104
X 2 16,1 - 8,075
3G 16,5 - 8,585
4G 17,1 - 9,3105
X 2 1,57,0 - 9,2115
3G 1,58,0 - 10,4135
4G 1,59,0 - 11,6165
5G 1,59,8 - 12,7190
X 2 2,59,0 - 11,6160
3G 2,59,6 - 12,4190
4G 2,510,7 - 13,8235
5G 2,511,9 - 15,3285
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.