Power and Control Cable; 1000V; 1 to 36 conductors; max. 630,00mm², Numbered Cores; LSZH, CECO™ / CEAC™, Flame Resistant; +90°C

Rubber Cable for Control/Command/Power H07ZZ-F – 0,6/1KV Heavy Duty

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

H07ZZ-F Cable: The Ultimate Solution for Safety and Performance.(HEAVY DUTY)Designed for the most demanding applications, the H07ZZ-F cable offers superior flexibility for indoor and outdoor installations. Its robust construction with high-tech elastomeric compounds ensures maximum durability and reliability, even in the harshest and most challenging environments.
  • Maximum Fire Safety: Halogen-free, flame-retardant, and emits low levels of toxic smoke.
  • Versatility for Every Environment: Ideal for humid, oily locations and even areas with a risk of explosion.
  • Robust and Reliable Construction: Highly resistant to mechanical stress, oils, and UV rays for a superior service life.
  • Wide Range of Applications: Perfect for power and control in indoor, outdoor, and mobile installations.
  • Superior Electrical Performance: Class 5 copper conductors and elastomeric insulation ensure maximum efficiency and secure connections.
PRODUCT DESIGN
  • Conductor: Bare copper wires, electrolytically annealed, class 5, according to IEC 60228
  • Insulation: CECO™ cross-linked rubber compound for heavy-duty applications. (HEAVY DUTY)
  • Inner Cover: CECO™ rubber compound for heavy-duty applications. (HEAVY DUTY)
  • Outer Cover: CEAC™ rubber compound for heavy-duty applications. (HEAVY DUTY)
  • Color: Black (other colors available upon request)
  • Nominal Voltage: 450/750 V (U₀/U)
  • AC Test Voltage: 2,5 kV
  • Operating Temperature (Fixed Use): -20°C to +90°C
  • Operating Temperature (Flexible Use): -5°C to +90°C
  • Conductor Short-Circuit Temperature: 250°C (Max. 5 sec)
  • Features: Halogen-free, low smoke emission, flame retardant, oil and UV resistant.
  • Applications: Power and control cables for indoor and outdoor use, in harsh conditions, medium mechanical stress, and in humid, oily, or explosion-risk locations.
  • Standards: EN 50525-3-21, VDE 0285-3-21, IEC 60245-4
DETAILS

Benefits

  • High Security: Halogen-free (LSZH) material, with low emission of smoke and toxic gases.
  • High Flexibility: Construction with class 5 conductors facilitates installation and handling.
  • Superior Resistance: Rubber compound resistant to oils, moisture, and UV rays.
  • Flame Protection: Flame-retardant properties that increase safety in case of fire.
  • Wide Temperature Range: Reliable operation from -20°C to +90°C in fixed installations.
  • Mechanical Durability: Designed to withstand medium mechanical stress conditions in industrial environments.
  • Internal and External Use: Ideal for permanent outdoor applications thanks to its UV resistance.
  • Robust Construction: Outer coating made of elastomeric compound for maximum protection.
  • Voltage Versatility: Allows use up to 1.000 V for fixed and protected installations.
  • Regulatory Compliance: Manufactured in accordance with stringent EN, VDE and IEC standards.

Applications

  • Public Places: Facilities in hospitals, schools, airports, and shopping malls where security is crucial.
  • General Industry: Power supply and equipment control in harsh environments.
  • Construction: Connecting tools and machines on construction sites.
  • External Applications: Cabling for outdoor projects requiring resistance to sun and weather.
  • Humid and Oily Environments: Ideal for workshops, industrial kitchens, and production areas.
  • Mobile Equipment: Power supply for portable machines and other heavy-duty devices.
  • Risk Zones: Suitable for use in areas with a risk of explosion.
  • Temporary Structures: Power supply for events, shows and fairs.
  • Control Systems: Connecting panels and automation devices across various sectors.
  • Fixed Installations: Power distribution as a power cable in protected installations.
TECHNICAL DATA

 

General information
BrandINNOVCABLE
Product typeFlexible power cord with rubber coating, halogen-free and low smoke emission (LSZH).
Electrical Parameters
Nominal VoltageUo/U: 450/750 V (Up to 1.000 V AC or DC permitted for fixed and protected installations).
Test Voltage2,5 kV AC
Current CapacityIn accordance with VDE 0298-4 and IEC 60364-5-52.
Conductor ResistanceIn accordance with IEC 60228 and VDE 0295.
Product Design
Conductor MaterialBare copper wires, electrolytically annealed, stranded (tinned conductor available upon request).
Driver ClassClass 5, according to IEC 60228 / VDE 0295.
SeparatorA suitable tape can be applied over the driver.
Vein Isolation MaterialCECO™ cross-linked rubber compound for heavy-duty applications.
Intermediate Cover MaterialCECO™ rubber compound for heavy-duty applications.
Exterior Roofing MaterialCEAC™ rubber compound for heavy-duty applications.
Cover ColorBlack (other colors available upon request).
Cable FormatRound
Product characteristics
Application AreaUse as a power and control cable in temporary indoor and permanent outdoor applications. Suitable for harsh conditions, medium mechanical stress, damp, oily, wet locations, and areas with a risk of explosion.
For continuous bendingYes.
Minimum Radius of CurvatureAccording to EN 50565-1 Table 3.
Temperature, fixed installation-20 °C to +90 °C.
Temperature, constant movement-5 °C to +90 °C.
Minimum Installation Temperature-5 ° C.
Maximum Temperature in the Conductor+250 °C in short circuit (max. 5 seconds).
Flame retardantYes, in accordance with IEC 60332-1-2 and IEC 60332-3-24.
Halogen-freeYes, in accordance with EN 60574-1.
Low smoke emissionYes.
Oil resistantYes, in accordance with EN 60811-404.
UV resistantYes.
Applicable Standards
ConstructionEN 50525-3-21, VDE 0285-3-21, IEC 60245-4
TestsEN 50395, EN 50396, IEC 60245-2
User GuideEN 50565-1/2, VDE 0298-565-1
CPR (Construction)EN 50575 (for single-track cables only)
ConformityRoHS, CE, EAC

 

DIMENSIONAL TABLE
Cross Section (mm²)Nominal Outside Diameter (mm)Approximate Weight (kg / km)Minimum Radius of Curvature (free movement) (mm)
Maximum Resistance of Conductors at 20°C (ohm/km)
1 x 1,56,2562513,3
1 x 2,56,871277,98
1 x 47,797314,95
1 x 68,4123343,3
1 x 1010,3191411,91
1 x 1611,5260461,21
1 x 2514,2388710,78
1 x 3515,5502780,554
1 x 5017,8680890,386
1 x 7020,19271210,272
1 x 9522,511851350,206
1 x 12024,614701480,161
1 x 15026,817971610,129
1 x 18529,521671770,106
1 x 2403328331980,0801
1 x 3003634422160,0641
1 x 40041,344592480,0486
1 x 50044,657482680,0384
1 x 63047,871782870,0287
2 x 18,41003419,5
2 x 1,59,41283813,3
2 x 2,511181447,98
2 x 412,6248634,95
2 x 614318703,3
2 x 1019,6601981,91
2 x 16227991321,21
2 x 2526,811841610,78
3 x 19,11213619,5
3 x 1,510,11554013,3
3 x 2,511,8217477,98
3 x 413,5300684,95
3 x 615390753,3
3 x 1021,17311271,91
3 x 1623,69801421,21
3 x 2529,214831750,78
3 x 3531,718751900,554
3 x 5036,625462200,386
3 x 7041,334292480,272
3 x 9546,644132800,206
4 x 110,11504019,5
4 x 1,511,21914513,3
4 x 2,513269657,98
4 x 414,9374754,95
4 x 616,7493843,3
4 x 10238941381,91
4 x 1625,812111551,21
4 x 2532,418671940,78
4 x 3535,123612110,554
4 x 5040,532062430,386
4 x 7045,943522750,272
4 x 9551,856463110,206
5 x 111,11824419,5
5 x 1,512,42356213,3
5 x 2,514,4331727,98
5 x 416,7469844,95
5 x 619622953,3
5 x 1025,310911521,91
5 x 1628,614961721,21
5 x 2525,923021550,78
6 x 1,514,63177313,3
6 x 2,516,8438847,98
6 x 419,3609974,95
7 x 1,514,63277313,3
7 x 2,516,8454847,98
7 x 419,3635974,95
12 x 1,519,25319613,3
12 x 2,522,17391337,98
12 x 425,810611554,95
18 x 1,522,474213413,3
18 x 2,52610501567,98
18 x 430,315071824,95
24 x 1,526,296715713,3
24 x 2,530,613821847,98
36 x 1,530134418013,3
36 x 2,535,219442117,98
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.