Power and Control Cable; Shielded with Tape + Steel Tape; Max. 10,00 mm²; Up to 1,0 mm² 500 V; From 1,50 mm² to 10,00 mm² 1000 V; 2 to 56 conductors; Numbered cores; HEPR / SHF1 / SHF1; Flame retardant; +70°C

Shielded Control/Command Cable in Tape (BF) / Steel Tape (FA) ATOX HEPR/SHF1 – NBR 16442

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Non-Tox Control Cable: Safety and Superior Performance for Your InstallationDesigned for maximum protection in control, command, and signaling circuits. This cable combines robust construction and flexibility with the safety of halogen-free technology, making it the ideal choice to ensure the continuity and reliability of your systems.
  • Maximum Human Safety: Low emission of smoke and toxic gases, essential for locations with high traffic.
  • Clean and Reliable Signal: Shielding that protects against electromagnetic interference, ensuring signal integrity.
  • Robustness for the Environment: Mechanical protection with steel tape and high resistance to moisture, UV and weathering.
  • Wide Versatility: Ideal for industrial automation, substations, electrical panels, power plants, and critical systems.
  • Equipment Protection: Halogen-free, it does not emit corrosive gases when burned, preserving your valuable assets.
PRODUCT DESIGN
  • Stranded conductor made of bare electrolytic copper wires, soft temper, stranding class 5 NBR NM 280.
  • Insulation in compound (HEPR - ethylene propylene rubber) 90°C.
  • Separator made of polyester tape and collective shielding made of aluminized polyester tape with tinned copper drain wire.
  • Intermediate layer made of halogen-free, flame-retardant thermoplastic compound (SHF1).
  • Application of galvanized steel tape.
  • Non-hygroscopic tape.
  • Halogen-free, flame-retardant thermoplastic compound (SHF1) covering in black.
DETAILS

Benefits

  • Enhanced Security: Halogen-free compound with low emission of smoke and toxic gases.
  • High mechanical protection: Application of steel tape that ensures resistance against impacts and crushing.
  • Signal without interference: Collective shielding that effectively protects against electromagnetic noise.
  • Excellent flexibility: Class 5 conductor that facilitates installation on routes with sharp curves.
  • Weather resistance: Suitable for outdoor environments, with protection against UV rays and moisture.
  • High temperature operation: HEPR insulation that withstands continuous operating temperatures up to 90°C.
  • Equipment protection: It does not emit corrosive gases during combustion, thus preserving electronic systems.
  • Versatile installation: It can be applied to electrical conduits, cable trays, cable ladders, and other infrastructure.
  • Regulatory compliance: It meets safety standards for locations with large concentrations of people.
  • Superior durability: Good resistance to certain chemicals, ideal for industry.

Applications

  • Industrial automation: Control, command and signaling circuits for machines and processes.
  • Power plants and substations: Power supply and equipment control in power generation systems.
  • Electrical panels: Connection of pushbuttons, contactors and other control devices.
  • Commercial buildings: Security systems in hospitals, airports, and shopping malls.
  • Chemical industry: Fixed installations that require safety and reliability in harsh environments.
  • Microprocessor-based systems: Connection of electronic equipment sensitive to interference.
  • Electrical equipment: Power supply and control for various industrial machines and tools.
  • Critical infrastructure: Installations with sensitive equipment where the absence of corrosive gases is required.
  • Structured cabling: Applications that require greater mechanical protection and fire safety.
  • Fixed installations: Installation in conduits, cable trays and raceways in industrial plants.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typeBF FA ATOX HEPR/SHF1 – NBR 16442 control cable.
Electrical Parameters
Insulation VoltageUp to 1,0 mm² - 500V / From 1,50 mm² to 10,00mm² - 1000V
Product Design
Conductor MaterialBare electrolytic copper wires, soft temper.
Driver DesignClass 5 stringing, according to NBR NM 280.
Base Material for Vein IsolationHEPR compound (ethylene propylene rubber) 90°C.
Road IdentificationBlack or white veins numbered sequentially. Can be constructed with colored veins upon request.
Includes protective conductor (ground).It can be manufactured with a green track (protective conductor) at the customer's request.
SeparatorPolyester tape.
ShieldedYes, collective shielding using aluminized polyester tape with tinned copper drain wire.
Intermediate Cover Base MaterialHalogen-free, flame-retardant thermoplastic compound (SHF1).
Mechanical ProtectionGalvanized steel strip.
Additional TapeNon-hygroscopic tape.
Base Material for the External CoveringHalogen-free, flame-retardant thermoplastic compound (SHF1).
Cover ColorBlack.
Product characteristics
Application AreaFixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, pushbuttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial areas, chemical plants, among others.
Special PropertiesLow emission of smoke and toxic gases; does not emit corrosive gases during combustion.
Maximum Conductor Temperature (Steady State)+90°C.
Maximum Conductor Temperature (Short Circuit)+250°C (duration of 5s).
Flame retardantYes, in accordance with NBR NM IEC 60332-3-23 (Category B).
Halogen-freeYes.
UV resistantYes.
Additional ResistanceResistant to weathering, moisture, and certain chemicals.
FlexibilityGood flexibility.
Applicable Standards
NBR 16442Halogen-free, low-smoke control cables for voltages up to 1 kV.
NM-280 / NM-IECInsulated cable conductors.
NBR NM IEC 60332-3-23 (Category B)Vertical flame burning test in category B.
NBR 6251Power cables with extruded insulation for voltages from 1 kV to 35 kV.
NBR 5410 / NBR 13570Low-voltage electrical installations and electrical installations in public gathering places.
DIMENSIONAL TABLE

 

Nominal Section (mm²)Number of DriversExternal Diameter (mm)Nominal Weight (kg/km)
0,5028,67124,33
0,5038,94140,46
0,5049,75179,62
0,5059,90195,93
0,50610,43211,63
0,50710,43221,21
0,50810,96239,31
0,50912,47280,95
0,501012,88302,14
0,501112,88310,24
0,501213,09326,40
0,501313,55347,42
0,501413,55355,15
0,501514,06380,75
0,501614,06388,18
0,501714,59409,37
0,501814,59416,30
0,501914,59423,38
0,502015,34453,99
0,502115,87470,54
0,502215,87481,65
0,502315,87497,16
0,502415,87503,70
0,502515,87519,04
0,7529,09137,29
0,7539,39157,27
0,75410,30203,06
0,75510,47222,20
0,75611,06242,20
0,75711,06255,38
0,75811,67277,56
0,75913,30324,89
0,751013,75350,01
0,751113,75361,52
0,751213,96381,71
0,751314,47406,63
0,751414,47417,74
0,751515,05447,27
0,751615,05458,03
0,751715,64483,14
0,751815,64493,35
0,751915,64503,72
0,752016,46539,01
0,752117,05559,46
0,752217,05573,81
0,752317,05592,57
0,752417,05602,33
0,752517,05620,90
1,0029,45149,04
1,0039,78172,66
1,00410,77224,46
1,00510,95247,32
1,00611,60270,41
1,00711,60287,03
1,00812,26313,06
1,00914,00365,59
1,001014,49394,42
1,001114,49409,21
1,001214,70433,20
1,001315,26461,81
1,001415,26476,15
1,001515,88509,99
1,001615,88523,36
1,001716,53552,18
1,001816,53565,55
1,001916,53579,10
1,002017,40618,73
1,002118,05642,86
1,002218,05660,35
1,002318,05682,24
1,002418,05695,13
1,002518,05716,81
1,50210,03169,85
1,50310,41200,22
1,50411,53262,65
1,50511,74291,54
1,50612,47321,30
1,50712,47344,31
1,50813,23377,41
1,50915,14439,26
1,501015,70474,94
1,501115,70495,87
1,501215,91526,85
1,501316,55562,27
1,501416,55582,70
1,501517,26622,79
1,501617,26642,78
1,501717,99678,46
1,501817,99697,77
1,501917,99717,29
1,502018,96764,82
1,502119,69795,76
1,502219,69819,16
1,502319,69846,95
1,502419,69865,71
1,502519,69893,27
2,50211,80227,56
2,50312,32275,80
2,50413,85367,66
2,50514,13412,29
2,50615,13459,71
2,50715,13499,52
2,50816,16551,48
2,50918,61638,90
2,501019,38692,79
2,501119,38729,77
2,501219,59779,33
2,501320,45832,87
2,501420,45869,17
2,501521,42927,45
2,501621,42963,16
2,501722,411017,04
2,501822,411051,81
2,501922,411086,88
2,502023,661155,75
2,502124,651204,78
2,502224,651243,52
2,502324,651286,67
2,502424,651320,70
2,502524,651363,53
4,00213,03280,51
4,00313,61343,55
4,00415,33458,68
4,00515,65516,56
4,00616,77578,60
4,00716,77632,45
4,00817,93699,93
4,00920,63807,02
4,001021,49875,87
4,001121,49926,29
4,001221,70990,70
4,001322,671059,10
4,001422,671108,70
4,001523,761181,91
4,001623,761230,79
4,001724,881299,59
4,001824,881347,37
4,001924,881395,50
4,002026,251480,96
4,002127,371544,79
4,002227,371596,45
4,002327,371652,51
4,002427,371699,38
4,002527,371755,06
6,00214,50355,63
6,00315,18444,22
6,00417,19595,62
6,00517,56677,08
6,00618,88764,45
6,00718,88842,87
6,00820,23936,80
6,00923,331075,84
6,001024,331170,50
6,001124,331244,76
6,001224,541334,97
6,001325,681429,04
6,001425,681502,32
6,001526,951601,28
6,001626,951673,69
6,001728,261768,25
6,001828,261839,34
6,001928,261910,94
6,002029,832024,42
6,002131,142113,87
6,002231,142188,72
6,002331,142267,96
6,002431,142337,95
6,002531,142416,74
10,00213,03280,51
10,00313,61343,55
10,00415,33458,68
10,00515,65516,56
10,00616,77578,60
10,00716,77632,45
10,00817,93699,93
10,00920,63807,02
10,001021,49875,87
10,001121,49926,29
10,001221,70990,70
10,001322,671059,10
10,001422,671108,70
10,001523,761181,91
10,001623,761230,79
10,001724,881299,59
10,001824,881347,37
10,001924,881395,50
10,002026,251480,96
10,002127,371544,79
10,002227,371596,45
10,002327,371652,51
10,002427,371699,38
10,002527,371755,06
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.