Power and Control Cable; Shielded with Tape + Steel Tape; Max. 10,00 mm²; Up to 1,0 mm² 500 V; From 1,50 mm² to 10,00 mm² 1000 V; 2 to 56 conductors; Numbered cores; PVC / PVC / PVC; Flame retardant; +70°C

Shielded Control/Command Cable in Tape (BF) / Steel Tape (FA) NBR 7289

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

BF FA Control Cable: The Ultimate Solution for Industrial AutomationDesigned for the most demanding industrial control and automation applications, this cable offers unparalleled performance. Its robust construction ensures superior protection and reliable signal transmission, keeping your equipment operating at peak efficiency and safety.
  • Double Protection for Maximum Security: Mechanical protection with steel tape and shielding against electromagnetic interference.
  • Extreme Durability in Any Environment: Resistant to UV rays, humidity, weather, and various chemical agents.
  • Flexibility and Easy Installation: High flexibility simplifies assembly in complex conduits, panels, and raceways.
  • Superior Versatility: Perfect for control, signaling, machines, substations and microprocessor systems.
  • Fire Safety: Flame-retardant properties that meet stringent safety standards, protecting your assets and lives.
PRODUCT DESIGN
  • Stranded conductor made of bare electrolytic copper wires, soft temper, stranding class 5 NBR NM 280.
  • Insulation made of thermoplastic compound based on polyvinyl chloride (PVC/A).
  • Separator made of polyester tape and collective shielding made of aluminized polyester tape with tinned copper drain wire.
  • Intermediate layer made of thermoplastic compound based on polyvinyl chloride (PVC/ST1).
  • Application of galvanized steel tape.
  • Non-hygroscopic tape.
  • Thermoplastic compound covering based on polyvinyl chloride (PVC/ST1).
DETAILS

Benefits

  • Superior Protection: Steel tape shielding ensures high mechanical resistance.
  • Clean and Safe Signal: Collective shielding against electromagnetic interference.
  • High Flexibility: Class 5 conductors facilitate installation in complex locations.
  • Weather resistance: Good performance against UV rays, humidity and weather variations.
  • Enhanced Security: Flame-retardant properties; does not propagate fire in case of a fire.
  • Chemical Durability: Resistant to certain chemicals, ideal for industry.
  • Installation Versatility: Suitable for a wide range of electrical infrastructures.
  • Clear Identification: Numbered channels that simplify and speed up electrical connections.
  • Operational Reliability: Built to ensure the continuity of industrial processes.
  • Customizable Options: It can be manufactured with compounds to resist oils and greases.

Applications

  • Industrial Automation: Control circuits in process automation systems.
  • Electrical Equipment: Used for controlling and signaling various types of equipment.
  • Control Panels: Connection and structured cabling of electrical panels and pushbuttons.
  • Machines and Engines: Power supply and control in industrial machine connections.
  • Microprocessor Systems: Secure signal transmission for sensitive systems.
  • Power Plants and Substations: Fixed installations in power plants and automation areas.
  • Chemical Industry: Applications in industrial environments, including chemical areas.
  • Electrical Infrastructure: Installation in electrical conduits, raceways, cable trays and cable ducts.
  • Fixed Installations: Ideal for circuits that do not require constant movement.
  • Special Projects: Robust solution for diverse needs in industrial plants.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typeBF FA Control Cable
Electrical Parameters
Insulation VoltageUp to 1,0 mm²: 500V. From 1,50 mm² to 10,00 mm²: 1000V.
Routine TestsElectrical resistance of the conductor at 20°C, Alternating current voltage, Insulation resistance.
Product Design
Conductor MaterialBare electrolytic copper wires, soft temper.
Driver ClassClass 5 stringing, according to NBR NM 280.
Vein Isolation MaterialThermoplastic compound based on polyvinyl chloride (PVC/A).
Road IdentificationWhite veins numbered sequentially.
Road Color OptionsIt can be constructed with colored veins upon request.
Includes protective conductor (ground).It can be manufactured with a green lane at the customer's request.
Internal SeparatorPolyester tape.
Collective ShieldingAluminized polyester tape with tinned copper drain wire for protection against electromagnetic interference.
Intermediate Cover MaterialThermoplastic compound based on polyvinyl chloride (PVC/ST1).
Mechanical ArmorGalvanized steel strip.
External SeparatorNon-hygroscopic tape.
Exterior Roofing MaterialThermoplastic compound based on polyvinyl chloride (PVC/ST1).
Product characteristics
Application AreaFixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, pushbuttons, power supply, microprocessor systems, automation of substations, power plants and industrial areas (chemical, etc.).
Installation ModeFixed conduit systems (embedded or exposed), raceways, duct banks, cable trays, cable ladders and electrical panels.
Maximum Temperature in the Conductor70 °C (for PVC/A insulation).
Flame retardantYes, flame retardant and self-extinguishing according to NBR NM IEC 60332-3-23 (Category B).
FlexibilityGood flexibility.
UV resistantYes.
Weather resistantYes.
Moisture ResistantYes.
Chemical ResistantResistance to certain chemicals.
Construction Options (Upon Request)
Optional Driver EquipmentTinned copper conductor.
Optional String Class2 class.
Optional Insulation MaterialPVC/E (105°C), HEPR (90°C), PE (80°C), XLPE (125°C).
Optional Coverage MaterialPE, PVC/E, PVC/ST2, special PVC (oil and grease resistant), LSZH (non-halogenated).
Optional Coverage FormatPerfectly cylindrical cover for use with cable glands in classified areas (Ex).
Applicable Standards
ABNT/MERCOSURNM-280 and NM-IEC.
ABNTNBR 6251, NBR 7289 (for PVC/PVC construction), NBR NM IEC 60332-3-23 (Category B).
Other Standards (for special constructions)NBR 7290 (XLPE or HEPR insulation), NBR 13248 (HEPR/LSZH insulation).
DIMENSIONAL TABLE
Nominal Section (mm²)Number of DriversExternal Diameter (mm)
Nominal Weight (kg/km)
0,528,67124,33
0,538,94140,46
0,549,75179,62
0,559,9195,93
0,5610,43211,63
0,5710,43221,21
0,5810,98239,31
0,5912,47280,95
0,51012,88302,14
0,51112,88310,24
0,51213,09326,4
0,51313,55347,42
0,51413,55355,15
0,51514,06380,75
0,51614,06388,18
0,51714,59409,37
0,51814,59416,3
0,51914,59423,38
0,52015,34453,99
0,52115,87470,54
0,52215,87481,65
0,52315,87497,16
0,52415,87503,7
0,52515,87519,04
0,7529,09137,29
0,7539,39157,27
0,75410,3203,06
0,75510,47222,7
0,75611,06242,2
0,75711,06255,38
0,75811,67277,56
0,75913,3324,89
0,751013,75350,01
0,751113,75361,52
0,751213,96381,71
0,751314,47406,63
0,751414,47417,74
0,751515,05447,27
0,751615,05458,03
0,751715,64483,14
0,751815,64493,36
0,751915,64503,72
0,752016,46539,01
0,752117,05559,46
0,752217,05573,81
0,752317,05592,57
0,752417,05602,33
0,752517,05620,9
129,45149,04
139,78172,66
1410,77224,46
1510,95247,32
1611,6270,41
1711,6287,03
1812,26313,06
1914365,59
11014,49394,42
11114,49409,21
11214,7433,2
11315,26461,81
11415,26476,15
11515,88509,39
11615,88523,36
11716,53552,18
11816,53565,55
11916,53579,1
12017,4618,73
12118,05642,86
12218,05660,35
12318,05682,24
12418,05695,13
12518,05716,81
1,5210,03169,86
1,5310,41200,22
1,5411,53262,65
1,5511,74291,54
1,5612,47321,3
1,5712,47344,31
1,5813,23377,41
1,5915,14439,26
1,51015,7474,54
1,51115,7495,87
1,51215,91526,86
1,51316,55562,27
1,51416,55582,7
1,51517,26622,79
1,51617,26642,78
1,51717,99678,46
1,51817,99697,77
1,51917,99717,29
1,52018,96764,82
1,52119,69795,76
1,52219,69819,16
1,52319,69846,95
1,52419,69865,71
2,5211,8227,56
2,5312,32275,8
2,5413,85367,66
2,5514,13412,29
2,5615,13469,71
2,5715,13499,52
2,5816,16551,48
2,5918,61638,9
2,51019,38692,79
2,51119,38729,77
2,51219,59779,33
2,51320,45832,97
2,51420,45869,17
2,51521,42927,45
2,51621,42963,16
2,51722,411017,04
2,51822,411051,81
2,51922,411086,88
2,52023,661155,75
2,52124,651204,78
2,52224,651243,52
2,52324,651286,67
2,52424,651320,7
2,52524,651363,53
4213,03280,51
4313,61343,55
4415,33458,68
4515,65516,56
4616,77578,6
4716,77632,45
4817,93699,93
4920,63807,02
41021,49875,87
41121,49926,29
41221,7990,7
41322,671059,1
41422,671108,7
41523,761181,91
41623,761230,79
41724,881299,59
41824,881347,37
41924,881395,5
42026,251480,96
42127,371544,79
42227,371596,45
42327,371652,51
42427,371699,38
42527,371755,06
6214,5355,63
6315,18444,22
6417,19595,62
6517,56677,08
6618,88764,45
6718,88842,87
6820,23936,8
6923,331075,84
61024,331170,5
61124,331244,76
61224,541334,97
61325,681429,04
61425,681502,32
61526,951601,2
61626,951673,69
61728,261768,26
61828,261839,34
61928,261910,84
62029,832024,42
62131,142113,87
62231,142188,72
62331,142267,96
62431,142337,95
62531,142415,74
10213,03280,51
10313,61343,55
10415,33458,68
10515,65516,56
10616,77578,6
10716,77632,45
10817,93699,93
10920,63807,02
101021,49875,87
101121,49926,29
101221,7990,7
101322,671059,1
101422,671108,7
101523,761181,91
101623,761230,79
101724,881299,59
101824,881347,37
101924,881395,5
102026,251480,96
102127,371544,79
102227,371596,45
102327,371652,51
102427,371699,38
102527,371755,06
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.