Power and Control Cable; Shielded with Steel Tape + Braid; Max. 10,00 mm²; Up to 1,0 mm² 500 V; From 1,50 mm² to 10,00 mm² 1000 V; 2 to 56 conductors; Numbered cores; PVC / PVC / PVC; Flame retardant; +70°C

Shielded Control/Command Cable in Steel Tape (BF) / Braid (TA) NBR 7289

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Double Shielded Control Cable for Industrial AutomationDesigned for the most demanding applications in industrial control and automation. This cable offers maximum reliability for control and signaling circuits, ensuring that your equipment operates accurately and without interruptions.
  • Superior Double Armor: Electromagnetic protection combined with robust galvanized steel braiding.
  • Pure and Reliable Signaling: Collective shielding that eliminates interference, guaranteeing data integrity.
  • Flexible and Easy to Install: Class 5 conductors for simplified handling in conduits and panels.
  • Resistance in Hostile Environments: Resistant to moisture, weathering, UV rays and chemical agents.
  • Versatility of Application: Ideal for industrial automation, machinery, substations, and microprocessor systems.
PRODUCT DESIGN
  • Stranded conductor made of bare electrolytic copper wires, soft temper, stranding class 5 NBR NM 280.
  • Insulation made of thermoplastic compound based on polyvinyl chloride (PVC/A).
  • Separator made of polyester tape and collective shielding made of aluminized polyester tape with tinned copper drain wire.
  • Intermediate layer made of thermoplastic compound based on polyvinyl chloride (PVC/ST1).
  • Application of galvanized steel braid.
  • Non-hygroscopic tape.
  • Thermoplastic compound covering based on polyvinyl chloride (PVC/ST1).
DETAILS

Benefits

  • Superior protection: Shielding with galvanized steel braiding that offers robust mechanical protection.
  • Signal without interference: Collective shielding with aluminized polyester tape for protection against electromagnetic interference.
  • High flexibility: Class 5 conductors that provide excellent flexibility for installation.
  • Weather resistance: Good resistance to UV rays, humidity and climatic variations.
  • Flame retardant safety: Meets the requirements of the NBR NM IEC 60332-3-23 standard, and does not propagate flames.
  • Guaranteed durability: Made of PVC that is resistant to certain chemicals, increasing its lifespan.
  • Clear identification: Sequentially numbered veins facilitate installation and maintenance.
  • Versatility in construction: It can be manufactured with different insulation and covering materials upon request.
  • Reliable isolation: Insulation voltage up to 1000V to ensure safe operation.
  • Certified quality: Manufactured in accordance with ABNT standards, with ISO 9001:2008 quality system.

Applications

  • Control circuits: Ideal for controlling and signaling various electrical equipment.
  • Industrial automation: Used in microprocessor-based systems and in substation automation.
  • Power plants: Application in fixed installations for process control in power generation.
  • Industrial areas: Perfect for chemical industries and other harsh environments.
  • Structured cabling: Used in the connection of machines and systems that require organization and protection.
  • Electrical panels: Connection of pushbuttons and power supply to components in control panels and switchboards.
  • Fixed installations: Versatile for use in electrical conduits, raceways, cable trays and cable ladders.
  • Signaling systems: Secure and reliable signal transmission across a variety of equipment.
  • Machine connections: It ensures safe power supply and control for industrial machinery in general.
  • Customized projects: It can be adapted for different sections and materials as needed for the project.
TECHNICAL DATA

 

General information
BrandINNOVCABLE
Product typeShielded control cable with aluminized tape and steel braid (BF TA), for fixed installations.
Electrical Parameters
Insulation Voltage500V (for cross-sections up to 1,0 mm²)
Insulation Voltage1000V (for cross-sections from 1,50 mm² to 10,00 mm²)
Product Design
Conductor MaterialBare electrolytic copper wires, soft temper.
Driver DesignClass 5 stringing, according to NBR NM 280.
Vein Isolation MaterialThermoplastic compound based on polyvinyl chloride (PVC/A).
Road IdentificationWhite veins numbered sequentially.
Protective Conductor (Ground)Optional, with a green lane.
Road Color CodeIt can be constructed with colored veins upon request.
Internal SeparatorPolyester tape.
Collective ShieldingAluminized polyester tape with tinned copper drain wire for protection against electromagnetic interference.
Intermediate Cover MaterialThermoplastic compound based on polyvinyl chloride (PVC/ST1).
Mechanical ProtectionGalvanized steel braid.
External SeparatorNon-hygroscopic tape.
Exterior Roofing MaterialThermoplastic compound based on polyvinyl chloride (PVC/ST1).
Cover ColorNot specified (usually black).
Product characteristics
Application AreaFixed installations in control, command and signaling circuits of electrical equipment, automation of substations, power plants, industrial areas, chemical plants, among others.
InstallationIt can be applied to electrical conduits, cable trays, duct banks, cable raceways, cable ladders, and electrical panels.
For Continuous FlexionNo, it's designed for fixed installations.
Maximum Temperature in the Conductor70 °C in steady state.
Flame RetardantYes, flame retardant and self-extinguishing according to NBR NM IEC 60332-3-23 (Category B).
UV resistantYes.
Additional ResistanceResistant to weathering, moisture, and certain chemicals.
Halogen-Free (LSZH)No (standard in PVC). LSZH manufacturing available upon request.
Oil ResistantAvailable with a special oil-resistant PVC compound upon request.
Construction Options (Upon Request)
ConductorTinned copper or class 2 stringing.
InsulationPVC/E (105°C), XLPE (125°C), HEPR (90°C), PE (80°C).
CoveragePE, PVC/E, PVC/ST2, special PVC (oil resistant), LSZH.
Applicable Standards
ABNT NBR NM 280Insulated cable conductors.
ABNT NBR NM IEC 60332-3-23Vertical bonfire burning test (Category B).
ABNT NBR 7289Construction of control cables with PVC/PVC insulation/sheathing.
ABNT NBR 6251Power cables with extruded insulation.
ABNT NBR 7290Optional construction with XLPE or HEPR insulation.
ABNT NBR 13248Optional construction with HEPR insulation and LSZH sheath.

 

DIMENSIONAL TABLE
Nominal Section (mm²)Number of DriversExternal Diameter (mm)
Nominal Weight (kg/km)
0,528,6117,32
0,538,95132,85
0,549,77169,84
0,559,92185,84
0,5610,44200,98
0,5710,44210,11
0,5810,99227,48
0,5912,49268,11
0,51012,89280,7
0,51112,89296,47
0,51213,1312,31
0,51313,56332,76
0,51413,56340,19
0,51514,07365,21
0,51614,07372,36
0,51714,6392,96
0,51814,6399,65
0,51914,6406,48
0,52015,36436,53
0,52115,88453,53
0,52215,88463,41
0,52315,88476,69
0,52415,88485,02
0,52515,88500,14
0,7529,1129,77
0,7539,41149,09
0,75410,31192,44
0,75510,48211,75
0,75611,07230,61
0,75711,07243,29
0,75811,69264,66
0,75913,31310,85
0,751013,76335,3
0,751113,76346,44
0,751213,97366,27
0,751314,49390,55
0,751414,49401,32
0,751515,06430,19
0,751615,06440,64
0,751715,65465,1
0,751815,65475,04
0,751915,65485,12
0,752016,47519,78
0,752117,06539,61
0,752217,06553,71
0,752317,06572,21
0,752417,06581,74
0,752517,06600,06
129,46141,1
139,79164
1410,78213,14
1510,96235,63
1611,61258,03
1711,61274,09
1812,28299,23
1914,01350,53
11014,5378,82
11114,5393,01
11214,71416,6
11315,27444,51
11415,27458,49
11515,89491,02
11615,89504,64
11716,54532,76
11816,54545,82
11916,54559,05
12017,42598,01
12118,06621,46
12218,06638,68
12318,06660,29
12418,06672,91
12518,06694,33
1,5210,02160,3
1,5310,39189,54
1,5411,51248,48
1,5511,72276,67
1,5612,45305,34
1,5712,45327,42
1,5813,2359,19
1,5915,1419,21
1,51015,66453,74
1,51115,66472,93
1,51215,87504,13
1,51316,51538,46
1,51416,51558,18
1,51517,21597,15
1,51617,21616,46
1,51717,94651,03
1,51817,94669,72
1,51917,94688,6
1,52018,9735
1,52119,63764,86
1,52219,63787,67
1,52319,63814,87
1,52419,63833,06
1,52519,63860,05
2,5211,81216,84
2,5312,33263,95
2,5413,86351,7
2,5514,14395,75
2,5615,14442,1
2,5715,14481,06
2,5816,17531,65
2,5918,62617,14
2,51019,39669,89
2,51119,39706,25
2,51219,6756,19
2,51320,46807,64
2,51420,46843,3
2,51521,43900,57
2,51621,43935,74
2,51722,43988,52
2,51822,431022,83
2,51922,431057,41
2,52023,671125,22
2,52124,671173,2
2,52224,671211,52
2,52324,671254,24
2,52424,671287,95
2,52524,671330,28
4213,04268,31
4313,62330,09
4415,34440,6
4515,66497,83
4616,78558,67
4716,78611,55
4817,94677,48
4920,64782,4
41021,5849,98
41121,5899,89
41221,71963,41
41322,691030,59
41422,691079,55
41523,771151,52
41623,771199,81
41724,891267,37
41824,891314,63
41924,891362,21
42026,261446,48
42127,391509,13
42227,391560,31
42327,391615,88
42427,391662,3
42527,391717,52
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.