Power and Control Cable; Shielded with Steel Tape + Braid; Max. 10,00 mm²; Up to 1,0 mm² 500 V; From 1,50 mm² to 10,00 mm² 1000 V; 2 to 56 conductors; Numbered cores; XLPE-HEPR / PVC; Flame retardant; +90°C

Shielded Control/Command Cable in XLPE-HEPR/PVC Steel Tape (BF) / Braided Steel (TA) – NBR 7290

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 "The exact total amount, applying the discounts for your volume bracket, will be automatically calculated in your cart."

Shielded Control Cable: Performance and Safety for Your Industry Developed for installations requiring maximum reliability in control and signaling. This cable guarantees the integrity of your signals and the protection of your equipment, ensuring fault-free communication and superior performance in critical environments.
  • Robust Superior Protection: Double shielding with steel braiding that eliminates interference and resists mechanical impacts.
  • High Outdoor Durability: Resistant to UV rays, moisture and weathering, perfect for indoor or outdoor applications.
  • Wide and Flexible Application: Ideal for automation, machine control, electrical panels, power plants and substations.
  • High Temperature Safety: Insulation rated to 90°C for continuous operation, offering greater reliability for your system.
  • Installation Flexibility: Class 5 conductor that facilitates assembly in complex layouts, saving time.
PRODUCT DESIGN
  • 1) Stranded conductor made of bare electrolytic copper wires, soft temper, stranding class 5 NBR NM 280.
  • 2) Insulation in compound (HEPR - ethylene propylene rubber) or XLPE 90°C.
  • 3) Separator made of polyester tape and collective shielding made of aluminized polyester tape with tinned copper drain wire.
  • 4) Intermediate layer made of thermoplastic compound based on polyvinyl chloride (PVC/ST1).
  • 5) Shielding made of galvanized steel braid.
  • 6) Non-hygroscopic tape.
  • 7) Thermoplastic compound coating based on polyvinyl chloride (PVC/ST2).
DETAILS

Benefits

  • High mechanical protection: Armor made with galvanized steel braid that protects against impacts.
  • Reliable signal transmission: Collective protection that prevents electromagnetic interference.
  • High flexibility: Class 5 stranded conductors that facilitate installation.
  • Weather resistance: UV-resistant, moisture-resistant, and weather-resistant coating.
  • It withstands high temperatures: HEPR or XLPE insulation for continuous operation up to 90°C.
  • Durability in harsh environments: Good resistance to certain chemicals.
  • Certified safety: Constructed in accordance with ABNT NBR 7290 standards.
  • Versatile installation: It can be applied to cable trays, cable ladders, ducts and panels.
  • Easy identification: Veins numbered sequentially to speed up connections.
  • Long service life: High-quality materials that minimize downtime and maintenance costs.

Applications

    • Command and control circuits: Used for operating pushbuttons, relays, and contactors.
    • Industrial signage: Connection of sensors, meters and signaling equipment.
    • Substation automation: Cabling for control and protection systems in power substations.
    • Machine power supply: Connection of motors and electrical equipment in fixed installations.
    • Electrical panels: Internal wiring of control panels, distribution boards and control centers.
    • Power plants: Application in auxiliary control and instrumentation circuits.
    • Industrial areas: Ideal for chemical, steel, and general manufacturing industries.
    • Microprocessor-based systems: Interconnection of PLCs and other sensitive electronic devices.
    • Structured cabling: Communication and control networks in industrial environments.
    • Electrical equipment: Robust solution for overhead cranes, conveyors and other machinery.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typeShielded control cable (aluminum tape + steel braid) for fixed installations.
Electrical Parameters
Insulation VoltageUp to 1,0mm²: 500V / From 1,5mm² to 10,0mm²: 1000V
Routine TestsElectrical resistance of the conductor at 20°C, AC voltage, Insulation resistance.
Product Design
Conductor MaterialBare electrolytic copper wires, soft temper. (Optional: tin-plated copper).
Driver DesignClass 5 stringing, according to NBR NM 280. (Optional: Class 2).
Base Material for Vein IsolationComposed of HEPR (ethylene propylene rubber) or XLPE 90°C.
Road IdentificationBlack or white veins numbered sequentially. (Optional: colored veins).
Includes protective conductor (ground).Available to order with a green lane.
SeparatorPolyester tape.
Electrostatic ShieldingCollective shielding using aluminized polyester tape with tinned copper drain wire.
Intermediate Cover Base MaterialThermoplastic compound based on polyvinyl chloride (PVC/ST1).
Mechanical ArmorGalvanized steel braid.
Cover SeparatorNon-hygroscopic tape.
Base Material for the External CoveringThermoplastic compound based on polyvinyl chloride (PVC/ST2).
Cover ColorNot specified.
Product characteristics
Application AreaFixed installations in control, command and signaling circuits, automation of substations, power plants and industrial areas. For use in conduits, raceways, cable trays and electrical panels.
FlexibilityGood flexibility for installation. Not suitable for continuous bending.
Maximum temperature in the driverSteady state: +90°C
Maximum short-circuit temperature+250°C (maximum duration of 5 seconds).
Flame retardantYes, in accordance with NBR NM IEC 60332-3-23 (Category B).
UV resistantYes.
Weather and moisture resistantYes.
Chemical resistantResistant to certain chemicals. (Optional: Special PVC resistant to oils and greases).
Halogen-freeAvailable upon request in LSZH (non-halogenated polyolefin compound) version.
Applicable Standards
ABNT NBR 7290Extruded insulated control cables for voltages up to 1 kV - Performance requirements.
ABNT NBR NM 280Insulated cable conductors.
ABNT NBR 6251Power cables with extruded insulation for voltages from 1 kV to 35 kV.
ABNT NBR NM IEC 60332-3-23Vertical wiring burn test in category B.
DIMENSIONAL TABLE

 

Nominal Section (mm²)Number of DriversExternal Diameter (mm)Nominal Weight (kg/km)
0,5028,68117,32
0,5038,95132,85
0,5049,77169,84
0,5059,92185,84
0,50610,44200,98
0,50710,44210,11
0,50810,99227,48
0,50912,49268,11
0,501012,89288,70
0,501112,89296,47
0,501213,10312,31
0,501313,56332,76
0,501413,56340,19
0,501514,07365,21
0,501614,07372,36
0,501714,60392,96
0,501814,60399,65
0,501914,60406,48
0,502015,36436,53
0,502115,88452,53
0,502215,88463,41
0,502315,88478,69
0,502415,88485,02
0,502515,88500,14
0,7529,10129,77
0,7539,41149,09
0,75410,31192,44
0,75510,48211,75
0,75611,07230,61
0,75711,07243,29
0,75811,69264,66
0,75913,31310,85
0,751013,76335,30
0,751113,76346,44
0,751213,97366,27
0,751314,49390,55
0,751414,49401,32
0,751515,06430,19
0,751615,06440,64
0,751715,65465,10
0,751815,65475,04
0,751915,65485,12
0,752016,47519,78
0,752117,06539,61
0,752217,06553,71
0,752317,06572,21
0,752417,06581,74
0,752517,06600,06
1,0029,46141,10
1,0039,79164,00
1,00410,78213,14
1,00510,96235,63
1,00611,61258,03
1,00711,61274,09
1,00812,28299,23
1,00914,01350,53
1,001014,50378,62
1,001114,50393,01
1,001214,71416,60
1,001315,27444,51
1,001415,27458,49
1,001515,89491,02
1,001615,89504,64
1,001716,54532,76
1,001816,54545,82
1,001916,54559,05
1,002017,42598,01
1,002118,06621,46
1,002218,06638,68
1,002318,06660,29
1,002418,06672,91
1,002518,06694,33
1,50210,02160,30
1,50310,39189,54
1,50411,51248,46
1,50511,72276,67
1,50612,45305,34
1,50712,45327,42
1,50813,20359,19
1,50915,10419,21
1,501015,66453,74
1,501115,66473,93
1,501215,87504,13
1,501316,51538,46
1,501416,51558,19
1,501517,21597,15
1,501617,21616,48
1,501717,94651,03
1,501817,94669,72
1,501917,94688,60
1,502018,90735,00
1,502119,63764,86
1,502219,63787,67
1,502319,63814,87
1,502419,63833,06
1,502519,63860,05
2,50211,61216,84
2,50312,33263,95
2,50413,86351,70
2,50514,14395,75
2,50615,14442,10
2,50715,14481,06
2,50816,17531,65
2,50918,62617,14
2,501019,39669,89
2,501119,39706,25
2,501219,60755,18
2,501320,46807,64
2,501420,46843,38
2,501521,43900,57
2,501621,43935,74
2,501722,43988,52
2,501822,431022,83
2,501922,431057,41
2,502023,671125,22
2,502124,671173,20
2,502224,671211,52
2,502324,671254,24
2,502424,671287,86
2,502524,671330,28
4,00213,04268,31
4,00313,62330,09
4,00415,34440,60
4,00515,66497,83
4,00616,78558,67
4,00716,78611,55
4,00817,94677,48
4,00920,64782,40
4,001021,50849,98
4,001121,50899,69
4,001221,71963,41
4,001322,691030,59
4,001422,691079,55
4,001523,771151,52
4,001623,771199,81
4,001724,891267,37
4,001824,891314,63
4,001924,891362,21
4,002026,261446,48
4,002127,391509,13
4,002227,391560,31
4,002327,391615,88
4,002427,391662,30
4,002527,391717,52
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.