Power and Control Cable; Steel Tape; Max. 10,00 mm²; Up to 1,0 mm² 500 V; From 1,50 mm² to 10,00 mm² 1000 V; 2 to 56 conductors; Numbered Cores; PVC/PVC; Flame Retardant; +70°C

Control/Command Cable Steel Tape (FA) NBR 7289

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

FA Control Cable: Robustness for Industrial AutomationIdeal for control, command, and signaling circuits that demand maximum reliability and protection. This cable ensures the integrity and performance of your equipment in industrial environments, connecting everything from machines and panels to complex automation systems with complete safety.
  • Robust Steel Armor: Galvanized steel tape that offers maximum mechanical protection against impacts and crushing.
  • Versatility in Critical Applications: Ideal for power plants, substations, chemical industries, and electrical equipment automation.
  • Superior Resistance: A compound with high durability against moisture, weathering, and UV rays, suitable for any environment.
  • Flame Retardant Safety: Material with flame-retardant properties that increases the protection of your installation against fire.
  • Installation Flexibility: It facilitates passage through electrical conduits and raceways, optimizing assembly time and cost.
PRODUCT DESIGN
  • Stranded conductor made of bare electrolytic copper wires, soft temper, stranding class 5 NBR NM 280.
  • Insulation made of thermoplastic compound based on polyvinyl chloride (PVC/A).
  • Separator made of polyester tape.
  • Intermediate layer made of thermoplastic compound based on polyvinyl chloride (PVC/ST1).
  • Galvanized steel tape was applied.
  • Non-hygroscopic tape.
  • Thermoplastic compound covering based on polyvinyl chloride (PVC/ST1).
DETAILS

Benefits

  • Robust Mechanical Protection: Steel tape reinforcement ensures high resistance against impacts and crushing.
  • High Flexibility: Class 5 stranded conductors, ideal for installations in winding paths and easy to handle.
  • Weather resistance: Developed to withstand humidity, climate variations, and the effects of UV rays.
  • Chemical Durability: Good resistance to certain chemicals, increasing its lifespan in harsh environments.
  • Fire Safety: Flame-retardant properties that meet the NBR NM IEC 60332-3-23 standard, preventing the propagation of fire.
  • Versatility in Installation: Suitable for mounting in conduits, trays, cable ladders and electrical panels.
  • Simplified Identification: The veins are numbered, which speeds up the connection and maintenance process.
  • Reliable Operation: It supports continuous operating temperatures up to 70°C.
  • Wide Range of Options: Manufacturing options with different compounds, sections, and colors are available upon request.
  • Quality Assurance: Manufactured in accordance with the main ABNT technical standards.

Applications

  • Control Circuits: Used for operating machines, pushbuttons, and electrical equipment.
  • Signaling Systems: Ideal for transmitting signals in industrial equipment and control panels.
  • Industrial Automation: Used in microprocessor systems and in the automation of processes in substations.
  • Machine Feeding: Used in power supply connections for various types of equipment in fixed installations.
  • Power Plants: Used in control and monitoring circuits in power generation plants.
  • Chemical and Petrochemical Industry: Its robustness makes it ideal for industrial and chemical areas.
  • Electrical Panels: Perfect for interconnecting components and creating structured cabling for panels.
  • Installations in Electrical Conduits: It can be safely installed in recessed or exposed electrical conduits.
  • Cable Tray Systems: Commonly used in industrial installations that utilize cable trays and conduits.
  • Engineering Projects: A versatile solution for various applications in fixed electrical installation projects.
TECHNICAL DATA
DIMENSIONAL TABLE
Nominal Section (mm²)Number of DriversExternal Diameter (mm)
Nominal Weight (kg/km)
0,528,52120,55
0,538,79136,52
0,549,6175,06
0,559,75191,31
0,5610,28206,86
0,5710,28216,32
0,5810,83234,22
0,5912,32275,41
0,51012,73296,44
0,51112,73304,46
0,51212,94320,44
0,51313,4341,31
0,51413,4348,96
0,51513,91374,4
0,51613,91381,75
0,51714,44402,78
0,51814,44409,65
0,51914,44416,66
0,52015,19447,03
0,52115,72463,48
0,52215,72474,48
0,52315,72489,93
0,52415,72496,41
0,52515,72511,69
0,7528,94133,37
0,7539,24153,17
0,75410,15198,3
0,75510,32217,85
0,75610,91237,17
0,75710,91250,22
0,75811,52272,18
0,75913,14319,03
0,751013,6343,97
0,751113,6355,28
0,751213,81375,39
0,751314,32400,13
0,751414,32411,15
0,751514,89440,5
0,751614,89451,17
0,751715,49476,11
0,751815,49486,24
0,751915,49496,54
0,752016,31531,57
0,752116,9551,85
0,752216,9566,14
0,752316,9584,82
0,752416,9594,52
0,752516,9614,02
129,29145,01
139,63168,43
1410,62219,51
1510,8242,27
1611,44265,17
1711,44281,63
1812,11307,42
1913,84359,45
11014,34388,08
11114,34402,76
11214,55426,56
11315,11454,98
11415,11469,23
11515,73502,27
11615,73516,14
11716,38544,77
11816,38558,06
11916,38571,52
12017,25610,98
12117,9634,83
12217,9652,25
12317,9674,06
12417,9686,87
12517,9708,49
1,529,85164,7
1,5310,23194,53
1,5411,35255,66
1,5511,56284,15
1,5612,28313,39
1,5712,28335,93
1,5813,04368,43
1,5914,94429,3
1,51015,5464,45
1,51115,5484,96
1,51215,71515,41
1,51316,34550,31
1,51416,34570,34
1,51517,05609,99
1,51617,05629,49
1,51717,78664,63
1,51817,78683,57
1,51917,78702,72
1,52018,74749,59
1,52119,47780,01
1,52219,47803,04
1,52319,47830,48
1,52419,47848,98
1,52519,47876,08
2,5211,58220,05
2,5312,1267,01
2,5413,61356,36
2,5513,89399,95
2,5614,88446,11
2,5714,88484,76
2,5815,9535,34
2,5918,33620,82
2,51019,09673,42
2,51119,09709,32
2,51219,3757,63
2,51320,16809,89
2,51420,16845,14
2,51521,11902,15
2,51621,11936,82
2,51722,1989,41
2,51822,11023,18
2,51922,11057,22
2,52023,331124,63
2,52124,321172,39
2,52224,321210,14
2,52324,321252,29
2,52424,321285,33
2,52524,321327,16
4212,88275,28
4313,46337,98
4415,18451,86
4515,49509,56
4616,62571,27
4716,62624,86
4817,78691,91
4920,48798,15
41021,34866,76
41121,34916,98
41221,55981,12
41322,521049,19
41422,521098,61
41523,611171,48
41623,611220,21
41724,731288,67
41824,731336,31
41924,731384,28
42026,11469,34
42127,221532,85
42227,221584,38
42327,221640,3
42427,221687,06
42527,221742,61
6214,35349,92
6315,03438,1
6417,04588,02
6517,41669,28
6618,73756,26
6718,73834,38
6820,08927,82
6923,171066
61024,181160,24
61124,181234,28
61224,391324,19
61325,531417,87
61425,531490,95
61526,81589,52
61626,81661,74
61728,111755,9
61828,111826,82
61928,111898,15
62029,682011,26
62130,992100,34
62230,992175,03
62330,992254,12
62430,992323,97
62530,992402,61
10216,58485,05
10317,42623,17
10419,9839,68
10520,36967,8
10621,981104,38
10721,981230,93
10823,651375,89
10927,361573,79
101028,611718,36
101128,611839,7
101228,821979,96
101330,222123,78
101430,222243,88
101531,782392,72
101631,782511,73
101733,42656,17
101833,42773,53
101933,42891,42
102035,283058,52
102136,93197,67
102236,93318,63
102336,93443,99
102436,93559,98
102536,93684,78
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.