Power and Control Cable; 300/500V; 2 to 60 conductors; max. 2,50mm²; PVC/PVC, Flame and oil resistant; +80°C

Harmonized H05VVC4V5-K Control/Command Cable

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

The Ideal Control Cable for Industrial AutomationDeveloped for the most demanding industrial applications where precision is essential. This flexible cable combines robust construction, safety, and superior signal transmission, ensuring maximum performance and reliability for your equipment.
  • Designed for High Security: Made of oil-resistant and flame-retardant PVC compound.
  • Signal without interference: Copper mesh shielding protects against electromagnetic interference.
  • Flexible and Versatile: For use in machinery and control systems, ideal for dry, humid, and oily environments.
  • Durability and Long Service Life: Robust construction that ensures durability even under low mechanical stress.
  • Increase your Productivity: Ensure the continuity of your operations with reliable data transmission, avoiding unexpected downtime.
PRODUCT DESIGN
  • Conductor: Annealed electrolytic bare copper, class 5
  • Insulation: PVC composite, type T12 (EN 50363)
  • Inner cover: PVC compound, type TM2 (50363-4-1)
  • Shielding: Tin-plated copper wire mesh
  • Outer cover: PVC composite, type TM5 (Oil resistant and flame retardant, EN 50363-4-1)
  • Gray color
  • Construction: EN 50525-2-51
  • General Requirements: EN 50525-1/2, EN 50575
  • User Guide: EN 50565-1/2
  • Electrical Tests: EN 50395
  • Non-Electrical Tests: EN 50396
  • Conductor Resistance: IEC 60228, VDE 0295, BS 6360
  • Flame Retardant: IEC 60332-1-2
  • Oil Resistant: IEC 60811-404, VDE 0473-811-404
  • Nominal Voltage: 300/500 V (U₀/U)
  • AC Test Voltage: 2 kV
  • Operating Temperature (Flexible Use): -5°C to +70°C
  • Operating Temperature (Fixed Use): -30°C to +70°C
  • Conductor Short-Circuit Temperature: 150°C (Max. 5 sec)
  • Minimum Installation Temperature: 5°C
  • Minimum Radius of Curvature: EN 50565-1 Table 3
  • Current Carrying Capacity: VDE 0298-4 Tab.11.
DETAILS

Benefits

  • Superior resistance to oils: External coating in PVC (TM5), immune to industrial oils and greases.
  • High flexibility: Class 5 conductors for installations with small bending radii.
  • Secure signal transmission: Effective shielding with copper braid that protects against electromagnetic interference (EMC).
  • Enhanced Security: PVC compound with flame-retardant properties, in accordance with IEC 60332-1-2 standard.
  • Versatile use: Suitable for installation in dry, humid, wet, and oily environments.
  • Chemical resistance: Designed to withstand contact with a variety of chemicals commonly used in industry.
  • Wide temperature range: Reliable operation in fixed installations with temperatures ranging from -30°C to +70°C.
  • Durable construction: High-quality insulation and roofing materials that ensure a long service life.
  • Easy installation: The cable's flexibility optimizes assembly and routing time in complex layouts.
  • Equipment protection: Shielding ensures the integrity of signals for sensitive electronic equipment.

Applications

  • Machines and tools: Connecting sensors and actuators in industrial equipment and machining centers.
  • Production lines: Transmission of control signals and data in continuous manufacturing processes.
  • Control systems: Cabling for control panels, programmable logic controllers (PLCs), and automation.
  • Assembly lines: Reliable communication between different workstations in automated processes.
  • Measurement systems: Sending accurate data for instrumentation, quality control, and laboratory equipment.
  • Data processing: Ideal for applications with low mechanical stress that require protection against electromagnetic noise.
  • Industry in general: Installations in dry, humid, or oil-containing environments, such as in the metallurgical industry.
  • Conveyor belts: Control and feeding of components in logistics and material handling systems.
  • Packaging equipment: Synchronization of movements and sensors in packaging machines.
  • Industrial automation: A robust solution for connecting devices in any factory automation environment.
TECHNICAL DATA
General information
BrandINNOVCABLE
CórdobaH05VVC4V5-K (NYSLYCYÖ-JZ)
Product typeShielded control cable, with PVC insulation and oil resistant.
Electrical Parameters
Nominal Voltage300/500 V (Uo/U)
Test Voltage2 kV
Conductor ResistanceAccording to IEC 60228, VDE 0295, BS 6360 (maximum values ​​specified per cross-section in the datasheet).
Current CapacityAccording to VDE 0298-4 Tab.11.
Product Design
Conductor MaterialPlain copper, electrolytic annealed. Tinned conductor available upon request.
Driver DesignBraided, class 5, according to IEC 60228.
Base Material for Vein IsolationPVC compound, type T12 (EN 50363).
Intermediate Cover Base MaterialPVC compound, type TM2 (EN 50363-4-1).
shieldingMesh of tinned copper wires.
Base Material for the External CoveringComposed of PVC, type TM5, oil resistant and flame retardant (EN 50363-4-1).
Cover ColorAsh.
Product characteristics
Application AreaSignal and control cables for machines, production lines, control systems, assembly lines, measurement systems, and data processing with low mechanical stress. Can be used in dry, humid, oily, and wet environments, and temporarily outdoors.
For continuous bendingYes.
Minimum Radius of CurvatureAccording to EN 50565-1 Table 3 (specific values ​​per diameter in the datasheet).
Temperature, fixed installation-30 °C to +70 °C.
Temperature, constant movement-5 °C to +70 °C.
Minimum Installation Temperature+5 °C.
Maximum temperature in the driverShort-circuit temperature: +150 °C (Max. 5 seconds).
Flame retardantYes, in accordance with IEC 60332-1-2.
Chemical resistantYes, it is resistant to various chemicals.
Oil resistantYes, in accordance with IEC 60811-404, VDE 0473-811-404.
Electromagnetic CompatibilityYes, shielded against electromagnetic interference.
Applicable Standards
ConstructionEN 50525-2-51
General requirementsEN 50525-1/2, EN 50575
User GuideEN 50565-1/2
Electrical TestsEN 50395
Non-Electrical TestsEN 50396
Driver's RulesIEC 60228, VDE 0295, BS 6360
ConformityEN 50575
DIMENSIONAL TABLE
Cross Section (mm²)Nominal Outside Diameter (mm)Approximate Weight (kg/km)Minimum Radius of Curvature (free movement) (mm)
Maximum Resistance of Conductors at 20°C (ohm/km)
2 x 0,508924039
2 x 0,758,41044226
2 x 18,81164419,5
2 x 1,5101545013,3
2 x 2,511,4200577,98
3 x 0,508,41044239
3 x 0,758,81184426
3 x 19,41364719,5
3 x 1,510,31675213,3
3 x 2,512233727,98
4 x 0,508,91174539
4 x 0,759,61404826
4 x 110,11575119,5
4 x 1,511,32015713,3
4 x 2,513,6297827,98
5 x 0,509,81404939
5 x 0,7510,31635226
5 x 1111905519,5
5 x 1,512,52487513,3
5 x 2,514,8360897,98
6 x 0,5010,31565239
6 x 0,7511,11885626
6 x 111,72145919,5
6 x 1,513,83018313,3
6 x 2,516421967,98
7 x 0,5011,31875739
7 x 0,7512,22257326
7 x 1132617819,5
7 x 1,515,13639113,3
7 x 2,516,84741017,98
12 x 0,5013,82758339
12 x 0,7514,63238826
12 x 115,63789419,5
12 x 1,517,548410513,3
12 x 2,5217281267,98
18 x 0,5015,53569339
18 x 0,7516,944110126
18 x 117,950710719,5
18 x 1,520,367112213,3
18 x 2,524,69101487,98
27 x 0,5018,649211239
27 x 0,7520,261112126
27 x 121,471012819,5
27 x 1,525,3100015213,3
27 x 2,529,814401797,98
36 x 0,5020,762112439
36 x 0,7522,375113426
36 x 123,990014319,5
36 x 1,528,4128617013,3
36 x 2,533,218651997,98
48 x 0,5023,679214239
48 x 0,7526102615626
48 x 128,2123316919,5
48 x 1,532,5167619513,3
48 x 2,537,824062277,98
60 x 0,5026,198115739
60 x 0,7528,3122017026
60 x 130,1142118119,5
60 x 1,535194621013,3
60 x 2,540,828122457,98
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.