Power and Control Cable; 450/750 V; 2 to 5 conductors; Max. 16,00 mm²; Numbered Cores, CECO™/PUR, Oil Resistant; -40°C/+90°C

Polyurethane Control / Command Cable PUR H07BQ-F

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Cable H07BQ-F: The Robust Solution for Demanding Industrial ApplicationsDesigned to overcome the toughest challenges on construction sites and in the agricultural sector. This cable combines robust construction with superior flexibility, ensuring reliable power where you need it most, withstanding mechanical stress and adverse conditions.
  • Durability for Heavy-Duty Use: Polyurethane (PUR) coating for maximum resistance against abrasion, oils and moisture.
  • Versatility in Multiple Applications: Ideal for construction sites, workshops, and power tools in dry or humid environments.
  • High Performance and Flexibility: Operates from -40°C to +90°C with a flexible conductor that facilitates installation.
  • Certified Safety and Compliance: Compliant with European standards, including RoHS, for your complete peace of mind.
  • A Smart Investment: Reduce downtime and maintenance costs, ensuring maximum productivity and safety in your operations.
PRODUCT DESIGN
  • Conductor material: bare copper wires
  • Driver class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
  • Insulation: Special elastomeric compound CECO™ 
  • External coating: PUR (Polyurethane)
  • Cover Color: Orange
  • Nominal Voltage Uo/U: 450/750V
  • Test Voltage: 2.5kV
  • Temperature Rating: Operating: -40°C to +90°C
  • Maximum Short-Circuit Temperature: 250°C (Max. 5 seconds)
  • Minimum Radius of Curvature: 5 x total diameter
DETAILS

Benefits

  • High durability: Polyurethane (PUR) coating for maximum durability.
  • Superior flexibility: Class 5 copper conductor for easy handling.
  • Chemical resistance: Ideal for environments with oils and greases.
  • Wide temperature range: Safe operation from -40°C to +90°C.
  • Use in humid environments: Suitable for dry, damp, or wet locations.
  • Mechanical robustness: Designed to withstand moderate mechanical stress.
  • Guaranteed security: In accordance with European standards EN 50525-2-21.
  • Reliable isolation: Rubber compound CECO™ .
  • High visibility: Orange coating for easy identification.
  • Abrasion resistant: Perfect for harsh conditions on construction sites.

Applications

  • Construction sites: Feeding tools and heavy equipment.
  • Agricultural sector: Connecting machines and equipment in agricultural workshops.
  • Industry in general: Power supply for industrial equipment.
  • Power tools: For use in drills, circular saws, and other tools.
  • Portable equipment: Ideal for inspection lamps and heating plates.
  • Temporary facilities: Application in buildings and temporary accommodations.
  • Aggressive environments: Where resistance to oils and abrasion is required.
  • Damp places: Electrical installations in areas subject to humidity.
  • Heavy machinery: Electrical connections for heavy-duty applications.
  • Fixed installations: It can be used in exposed installations.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typeCable H07BQ-F
Electrical Parameters
Rated voltageUo/U: 450/750V
Test Voltage2.5 kV
Conductor Resistance (at 20°C)1.5 mm²: 13.3 Ω/km
2.5 mm²: 7.98 Ω/km
4 mm²: 4.95 Ω/km
6 mm²: 3.30 Ω/km
10 mm²: 1.91 Ω/km
16 mm²: 1.21 Ω/km
Product Design
Conductor MaterialFlexible copper, class 5
Roadway Isolation MaterialCECO™ special elastomeric compound
Exterior Roofing MaterialPolyurethane (PUR)
Cover ColorOrange
Road Identification2 ways: Blue, Brown
3 channels: Green/Yellow, Blue, Brown
4-way: Green/Yellow, Brown, Black, Gray
5 channels: Green/Yellow, Brown, Black, Gray, Blue
Product characteristics
Application AreaFor use in agricultural workshops, construction sites, heavy-duty applications, and powering industrial and agricultural machinery and equipment where cables are subject to medium mechanical stress. Suitable for use in dry, damp, or wet locations; fixed installations.
Operating Temperature-40°C to +90°C
Maximum Short-Circuit Temperature+250 °C (Max. 5 seconds)
Minimum Radius of Curvature5 x total diameter
Water ResistanceAD7 in accordance with IEC 60364-3
Standards and Compliance
Applicable StandardsΕΝ 50525-2-21, EN 60228, EN 50363-1, EN 50363-10-2, IEC/EN 60724
Directives and RegulationsConstruction Products Regulation (CPR) EN 50575
Low Voltage Directive 2014/35/EU
RoHS Directive 2015/65/EU
REACH Directive EC 1907/2006
DIMENSIONAL TABLE
NUMBER OF DRIVERSNOMINAL SECTION (mm²)NOMINAL INSULATION THICKNESS (mm)NOMINAL COVER THICKNESS (mm)NOMINAL OUTER DIAMETER (mm)NOMINAL WEIGHT (kg/km)
210.80.97.664
21.50.81.08.482
22.50.91.19.8134
241.01.211.4168
310.81.08.379
31.50.81.08.997
32.50.91.110.4166
341.01.312.3210
361.01.413.7281
3101.22.118.1490
410.81.09.094
41.50.81.19.9121
42.50.91.211.6210
441.01.413.7262
461.01.515.2351
4101.22.219.9607
510.81.110.0113
51.50.81.211.0146
52.50.91.312.9256
541.01.515.2318
561.01.616.8424
5101.22.323.9855
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.