Power and Control Cable; 500V to 0,6/1 kV; 2 to 12 conductors; max. 95,00 mm²; PVC/PVC, Flame resistant; +80°C

PVC Control/Command Cable JB/OB YCY

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

ÖPVC-JB/OB YCY Shielded Control Cable for Superior Industrial PerformanceDesigned for electrical installations requiring maximum reliability in data and signal transmission. Ensures superior performance, safety, and a stable connection for control and automation in diverse industrial environments.
  • Superior Shielding with EMC: A copper mesh that ensures data transmission without loss or electromagnetic interference.
  • High Chemical and Mechanical Resistance: Protected against oils, acids and bases, with internal sheath reinforcement.
  • Versatility in Applications: Ideal for fixed or flexible installations in dry, damp, and wet environments.
  • Fire Safety: Self-extinguishing and flame-retardant material, ensuring greater protection for your installation.
  • Performance in Extreme Temperatures: Reliable operation over a wide temperature range, from -40°C to +80°C.
PRODUCT DESIGN
  • Conductor material: bare copper wires
  • Conductor class: according to IEC 60228 cl. 5
  • Core insulation: PVC
  • Core identification: colored: up to 5 cores according to DIN VDE 0293-308; from 6 cores Innovcable color code; G: with GNYE
  • Twist: Twisted in layers
  • Inner cover material: PVC
  • Overall shielding: tinned copper braid, approximately 85% coverage.
  • Outer cover material: PVC
  • Cover color: transparent
DETAILS

Benefits

  • Reliable signal transmission: Copper mesh shielding for protection against electromagnetic interference (EMC).
  • High chemical resistance: It is highly resistant to specified acids, bases, and oils.
  • Excellent flexibility: Class 5 conductors that allow for flexible and easy applications.
  • Enhanced mechanical protection: It has an internal lining that ensures greater robustness and durability.
  • Wide temperature range: Safe operation in fixed installations from -40°C to +80°C.
  • Fire safety: Self-extinguishing and flame-retardant material, in accordance with IEC 60332-1 standard.
  • Versatile installation: Suitable for fixed and flexible applications without tensile stress.
  • Suitable for use in various environments: Ideal for installation in dry, damp, and wet locations.
  • Clear visual inspection: The transparent outer coating allows for easy verification of the shielding.
  • Secure connectivity: Designed for power supply and control, ensuring lossless data transmission.

Applications

  • Facilities engineering: As a power and control cable in various electrical installations.
  • Industrial automation: Connecting sensors and actuators in automated production lines.
  • Machines and tools: Wiring for industrial equipment that requires interference-free signals.
  • Control panels: Connecting components in electrical control and distribution panels.
  • Transportation systems: Used in conveyor belts and other material handling systems.
  • Measurement and control technology: For transmitting signals in test and control equipment.
  • Packaging industry: Feeding power into machines on packaging lines that require stable communication.
  • Air conditioning systems: In control circuits for heating, ventilation and air conditioning.
  • Equipment construction: A versatile solution for customized machine and device projects.
  • Building installations: Applications in building automation systems for control and supervision.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typeShielded PVC control, power and connection cable for lossless data and signal transmission.
Electrical Parameters
Nominal VoltageUo/U: up to 16mm² 300/500V, from 25mm² 0,6/1kV
Test Voltage4 kV
Insulation ResistanceMinimum of 20 MΩ x km
Current CapacityAccording to DIN VDE, see technical guides.
EMC ComplianceYes, EMC compliant shielding.
Product Design
Conductor MaterialBare copper wires.
Driver ClassAccording to IEC 60228 class 5.
Conductor ResistanceAccording to IEC 60228 class 5.
Includes protective conductor (ground).Yes (JB versions), with green/yellow driver.
Type of TwistTwisted veins in layers.
shieldingTin-plated copper mesh, approximately 85% coverage.
Base Material for Vein IsolationPVC
Inner Cover Base MaterialPVC
Base Material for the External CoveringPVC
Abbreviation for Roofing MaterialPVC
Cover ColorTransparent
Road IdentificationUp to 5 cores: colored according to DIN VDE 0293-308; From 6 cores onwards: Innovcable color code.
Product characteristics
Application AreaElectrical installations, for fixed installation and flexible applications without tensile stress and without a defined cable guide. Suitable for dry, damp and wet environments.
For continuous bendingYes, for flexible applications without tensile stress.
Minimum Radius of CurvatureFixed installation: 6 x cable diameter; Constant movement: 15 x cable diameter.
Traction loadNot applicable, it must be installed without tensile stress.
Temperature, fixed installation-40 °C to +80 °C.
Temperature, constant movement-15 °C to +70 °C.
Maximum temperature in the driver+70 °C in operation; +150 °C in case of short circuit.
Flame retardantSelf-extinguishing and flame retardant according to IEC 60332-1.
UV resistantFor external use only with UV protection.
Chemical resistantHighly resistant to acids, bases, and specified oil types.
Oil resistantYes, resistant to specified oil types.
Standards and Approvals
Basic StandardSimilar to EN 50525-2-51.
Applicable StandardsIEC 60228 cl. 5; DIN VDE 0293-308; IEC 60332-1.
Manufactured according toCE, EAC, CPR Eca
DIMENSIONAL TABLE
TypeESG/SRIOuter-Ø [mm]Cu Index [kg/km]Weight [kg/km]
ÖPVC-JB/OB-YCY 300/500 V
X 2 0,56,94174
3G 0,57,34678
4G 0,57,95595
5G 0,58,466111
7G 0,59,181140
12G 0,511,5139227
X 2 0,757,54677
3G 0,757,95891
X 3 0,757,95891
4G 0,758,464109
5G 0,759,177136
6G 0,759,888167
7G 0,759,7102174
8G 0,7511,2104214
12G 0,7512,7177270
X 2 17,95691
3G 18,265107
4G 18,878137
5G 19,689164
7G 110,4113199
12G 113,5188330
X 2 1,58,765115
3G 1,5983137
4G 1,59,7100173
5G 1,510,6125210
7G 1,511,4196282
12G 1,515,2280435
X 2 2,510112160
3G 2,510,5146210
4G 2,511,5167267
5G 2,512,5200319
7G 2,514288395
12G 2,518,2477640
4G 413,7237369
5G 415,3280446
7G 416,6388556
4G 616,1318503
5G 617,3441611
7G 618,8505798
4G 1019,4558764
5G 1021,8714943
4G 1622,68041.080
5G 1625,21.0531.325
ÖPVC-JB/OB-YCY 0,6/1 kV
4G 2528,91.2891.624
5G 2531,81.4462.270
4G 3532,21.6802.135
5G 3536,41.9752.771
4G 5038,82.3423.362
4G 7043,73.1034.320
4G 9550,44.0555.849
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.