Power and Control Cable; 500V to 0,6/1 kV; 2 to 50 conductors; max. 95,00 mm²; PVC/PVC, Flame and oil resistant; +80°C

PVC JB/OB YSY Control / Command Cable

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

ÖPVC-JB/OB-YSY Control Cable: Triple Protection for Critical SystemsDesigned to be the ultimate solution for electrical installations, this control and connection cable offers superior performance in fixed or flexible applications. Its robust construction with triple shielding ensures maximum safety and durability for your operation.
  • Superior Mechanical Protection: Braided steel mesh that offers extremely high resistance against impacts, crushing, and mechanical stress.
  • Effective Electromagnetic Shielding: The steel braid ensures clean, interference-free signals, acting as an efficient shield.
  • Versatility and Wide Application: Ideal for automation and control in dry, humid, or wet environments, in fixed or mobile installations.
  • Chemical Resistance and Durability: Made of PVC compound resistant to acids, bases and oils, ensuring a long service life.
  • Fire Safety: Self-extinguishing and flame-retardant material for maximum safety, protecting your assets and your team.
PRODUCT DESIGN
  • Conductor material: bare copper wires
  • Conductor class: according to IEC 60228 cl. 5
  • Core insulation: PVC
  • Core identification: JB/OB: colored - up to 5 cores according to DIN 293-308, from 6 cores Innovcable color code; G: with GNYE
  • Formation: Layered fan section
  • Inner cover material: PVC
  • Overall shielding: braid of galvanized steel wires
  • Outer cover material: PVC
  • Cover color: transparent
DETAILS

Benefits

  • Superior Mechanical Protection: The steel wire braid provides robust protection against impacts and crushing.
  • High Chemical Resistance: PVC compound highly resistant to oils, acids and bases in industrial environments.
  • Electromagnetic Shielding: The steel mesh protects against interference, ensuring the integrity of the control signal.
  • Enhanced Security: It has self-extinguishing and flame-retardant properties, increasing the safety of the installation.
  • Wide Temperature Range: Reliable operation in fixed installations ranging from -30°C to +80°C.
  • Installation Versatility: Suitable for use in dry, damp, and wet environments.
  • Flexible Applications: Ideal for installations with moderate movement, without traction effort.
  • Reliable Isolation: Subjected to a test voltage of 4 kV to ensure high electrical performance.
  • Triple Protection: It guarantees high durability with internal and external coating and steel mesh.
  • Ease of Handling: Constructed with class 5 flexible conductors, which facilitate field installation.

Applications

  • Machines and Tools: Connection and control of various equipment in industrial production environments.
  • Production Lines: Used as a power and signaling cable in manufacturing and assembly systems.
  • Control Panels: Internal wiring of electrical control panels and motor control centers.
  • Conveyor Systems: Ideal for conveyors and other material handling equipment.
  • Industrial Facilities: Perfect for fixed electrical installations or those requiring moderate flexibility.
  • Mechanical Engineering: Applications in the construction of machinery, equipment, and industrial plants.
  • Aggressive Environments: Where protection against moisture, oils, acids or bases is required.
  • Control Circuits: Secure transmission of signals to sensors and actuators in automated systems.
  • Electrical Power Supply: As a power cable for supplying power to electrical installations and components.
  • Industry in General: A versatile solution for engineering and industrial maintenance projects.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typeControl, power and connection cable made of PVC with steel braid shielding.
Electrical Parameters
Nominal VoltageUo/U: 0,6/1 kV
Test Voltage4 kV
Conductor ResistanceAccording to IEC 60228 class 5.
Insulation ResistanceMinimum of 20 MΩ x km.
Current CapacityAccording to DIN VDE, see technical guidelines.
Product Design
Conductor MaterialBare copper wires.
Driver ClassClass 5, according to IEC 60228.
Includes protective conductor (ground).Yes (GNYE).
Type of TwistTwisted veins in layers.
ShieldedYes, galvanized steel wire mesh.
Base Material for Vein IsolationPVC
Intermediate Cover Base MaterialPVC
Base Material for the External CoveringPVC
Cover ColorTransparent.
Road IdentificationColored cables up to 5 cores (DIN 293-308), from 6 cores onwards, Innovcable color code.
Product characteristics
Application AreaPower, control and connection cable for electrical installations, for fixed installation and flexible applications without tensile stress. Suitable for dry, damp and wet environments.
For continuous bendingYes, for flexible applications without defined routing.
Traction loadNot designed for tensile stress.
Minimum Radius of Curvature (Fixed)6 x cable diameter
Minimum Radius of Curvature (Mobile)15 x cable diameter
Temperature, fixed installation-30 °C to +80 °C.
Temperature, constant movement-15 °C to +70 °C.
Maximum temperature in the driver+70 °C in operation; +150 °C in case of short circuit.
Flame retardantYes, self-extinguishing according to IEC 60332-1.
UV resistantFor external use only with additional UV protection.
Chemical resistantHighly resistant to acids, bases, and specified oil types.
Oil resistantYes, to specified oil types.
NotesIt should not be buried. Do not store outdoors or in damp places.
Applicable Standards
IEC 60228 cl. 5Conductor standard.
DIN VDE 0293Road identification.
IEC 60332-1Behavior in case of fire (flame retardant).
EN 50525-2-51Similar to this standard.
DIMENSIONAL TABLE
TypeDimensãoExternal Diameter [mm]Weight [kg/km]
ÖPVC-JB/OB-YSY 300/500 VX 2 0,57,280
ÖPVC-JB/OB-YSY 300/500 V3G 0,57,792
ÖPVC-JB/OB-YSY 300/500 VX 3 0,57,792
ÖPVC-JB/OB-YSY 300/500 V4G 0,58,1102
ÖPVC-JB/OB-YSY 300/500 V5G 0,58,6119
ÖPVC-JB/OB-YSY 300/500 V7G 0,59,7147
ÖPVC-JB/OB-YSY 300/500 V12G 0,511,6213
ÖPVC-JB/OB-YSY 300/500 VX 2 0,757,897
ÖPVC-JB/OB-YSY 300/500 V3G 0,758,1110
ÖPVC-JB/OB-YSY 300/500 V4G 0,758,6125
ÖPVC-JB/OB-YSY 300/500 V5G 0,759,4144
ÖPVC-JB/OB-YSY 300/500 V7G 0,7510,3171
ÖPVC-JB/OB-YSY 300/500 V12G 0,7512,8260
ÖPVC-JB/OB-YSY 300/500 VX 2 18,2114
ÖPVC-JB/OB-YSY 300/500 V3G 18,5128
ÖPVC-JB/OB-YSY 300/500 V4G 19,3143
ÖPVC-JB/OB-YSY 300/500 V5G 19,8166
ÖPVC-JB/OB-YSY 300/500 V7G 111201
ÖPVC-JB/OB-YSY 300/500 V8G 111,5197
ÖPVC-JB/OB-YSY 300/500 V12G 113,6322
ÖPVC-JB/OB-YSY 300/500 VX 2 1,58,9146
ÖPVC-JB/OB-YSY 300/500 V3G 1,59,3157
ÖPVC-JB/OB-YSY 300/500 V4G 1,59,9180
ÖPVC-JB/OB-YSY 300/500 V5G 1,510,8216
ÖPVC-JB/OB-YSY 300/500 V7G 1,511,9264
ÖPVC-JB/OB-YSY 300/500 V12G 1,515,1434
ÖPVC-JB/OB-YSY 300/500 VX 2 2,510,4185
ÖPVC-JB/OB-YSY 300/500 V3G 2,511213
ÖPVC-JB/OB-YSY 300/500 V4G 2,511,9253
ÖPVC-JB/OB-YSY 300/500 V5G 2,512,8301
ÖPVC-JB/OB-YSY 300/500 V7G 2,514,3410
ÖPVC-JB/OB-YSY 300/500 V12G 2,518650
ÖPVC-JB/OB-YSY 300/500 VX 2 412,5329
ÖPVC-JB/OB-YSY 300/500 V3G 412,6343
ÖPVC-JB/OB-YSY 300/500 V4G 413,9357
ÖPVC-JB/OB-YSY 300/500 V5G 415504
ÖPVC-JB/OB-YSY 300/500 V7G 416,4640
ÖPVC-JB/OB-YSY 300/500 V3G 615,5450
ÖPVC-JB/OB-YSY 300/500 V4G 615,8495
ÖPVC-JB/OB-YSY 300/500 V5G 617,2592
ÖPVC-JB/OB-YSY 300/500 V7G 618,9845
ÖPVC-JB/OB-YSY 300/500 V4G 1019,41153
ÖPVC-JB/OB-YSY 300/500 V5G 1021,51352
ÖPVC-JB/OB-YSY 300/500 V7G 1023,41551
ÖPVC-JB/OB-YSY 300/500 V4G 1622,91360
ÖPVC-JB/OB-YSY 300/500 V5G 1624,61740
ÖPVC-JB/OB-YSY 300/500 V7G 1627,22166
ÖPVC-JB/OB-YSY 0,6/1 kV3G 2526,21630
ÖPVC-JB/OB-YSY 0,6/1 kV4G 2528,92020
ÖPVC-JB/OB-YSY 0,6/1 kV5G 2531,82465
ÖPVC-JB/OB-YSY 0,6/1 kV4G 3532,22570
ÖPVC-JB/OB-YSY 0,6/1 kV5G 35363185
ÖPVC-JB/OB-YSY 0,6/1 kV4G 5038,23515
ÖPVC-JB/OB-YSY 0,6/1 kV4G 7043,84810
ÖPVC-JB/OB-YSY 0,6/1 kV4G 9550,46360
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.