Power and Control Cable; 500V to 0,6/1 kV; 2 to 50 conductors; max. 95,00 mm²; PVC/PVC, Flame and oil resistant; +80°C
PVC JB/OB YSY Control / Command Cable
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Superior Mechanical Protection: Braided steel mesh that offers extremely high resistance against impacts, crushing, and mechanical stress.
- Effective Electromagnetic Shielding: The steel braid ensures clean, interference-free signals, acting as an efficient shield.
- Versatility and Wide Application: Ideal for automation and control in dry, humid, or wet environments, in fixed or mobile installations.
- Chemical Resistance and Durability: Made of PVC compound resistant to acids, bases and oils, ensuring a long service life.
- Fire Safety: Self-extinguishing and flame-retardant material for maximum safety, protecting your assets and your team.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | INNOVCABLE |
| Product type | Control, power and connection cable made of PVC with steel braid shielding. |
| Electrical Parameters | |
| Nominal Voltage | Uo/U: 0,6/1 kV |
| Test Voltage | 4 kV |
| Conductor Resistance | According to IEC 60228 class 5. |
| Insulation Resistance | Minimum of 20 MΩ x km. |
| Current Capacity | According to DIN VDE, see technical guidelines. |
| Product Design | |
| Conductor Material | Bare copper wires. |
| Driver Class | Class 5, according to IEC 60228. |
| Includes protective conductor (ground). | Yes (GNYE). |
| Type of Twist | Twisted veins in layers. |
| Shielded | Yes, galvanized steel wire mesh. |
| Base Material for Vein Isolation | PVC |
| Intermediate Cover Base Material | PVC |
| Base Material for the External Covering | PVC |
| Cover Color | Transparent. |
| Road Identification | Colored cables up to 5 cores (DIN 293-308), from 6 cores onwards, Innovcable color code. |
| Product characteristics | |
| Application Area | Power, control and connection cable for electrical installations, for fixed installation and flexible applications without tensile stress. Suitable for dry, damp and wet environments. |
| For continuous bending | Yes, for flexible applications without defined routing. |
| Traction load | Not designed for tensile stress. |
| Minimum Radius of Curvature (Fixed) | 6 x cable diameter |
| Minimum Radius of Curvature (Mobile) | 15 x cable diameter |
| Temperature, fixed installation | -30 °C to +80 °C. |
| Temperature, constant movement | -15 °C to +70 °C. |
| Maximum temperature in the driver | +70 °C in operation; +150 °C in case of short circuit. |
| Flame retardant | Yes, self-extinguishing according to IEC 60332-1. |
| UV resistant | For external use only with additional UV protection. |
| Chemical resistant | Highly resistant to acids, bases, and specified oil types. |
| Oil resistant | Yes, to specified oil types. |
| Notes | It should not be buried. Do not store outdoors or in damp places. |
| Applicable Standards | |
| IEC 60228 cl. 5 | Conductor standard. |
| DIN VDE 0293 | Road identification. |
| IEC 60332-1 | Behavior in case of fire (flame retardant). |
| EN 50525-2-51 | Similar to this standard. |
| Type | Dimensão | External Diameter [mm] | Weight [kg/km] |
| ÖPVC-JB/OB-YSY 300/500 V | X 2 0,5 | 7,2 | 80 |
| ÖPVC-JB/OB-YSY 300/500 V | 3G 0,5 | 7,7 | 92 |
| ÖPVC-JB/OB-YSY 300/500 V | X 3 0,5 | 7,7 | 92 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 0,5 | 8,1 | 102 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 0,5 | 8,6 | 119 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 0,5 | 9,7 | 147 |
| ÖPVC-JB/OB-YSY 300/500 V | 12G 0,5 | 11,6 | 213 |
| ÖPVC-JB/OB-YSY 300/500 V | X 2 0,75 | 7,8 | 97 |
| ÖPVC-JB/OB-YSY 300/500 V | 3G 0,75 | 8,1 | 110 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 0,75 | 8,6 | 125 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 0,75 | 9,4 | 144 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 0,75 | 10,3 | 171 |
| ÖPVC-JB/OB-YSY 300/500 V | 12G 0,75 | 12,8 | 260 |
| ÖPVC-JB/OB-YSY 300/500 V | X 2 1 | 8,2 | 114 |
| ÖPVC-JB/OB-YSY 300/500 V | 3G 1 | 8,5 | 128 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 1 | 9,3 | 143 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 1 | 9,8 | 166 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 1 | 11 | 201 |
| ÖPVC-JB/OB-YSY 300/500 V | 8G 1 | 11,5 | 197 |
| ÖPVC-JB/OB-YSY 300/500 V | 12G 1 | 13,6 | 322 |
| ÖPVC-JB/OB-YSY 300/500 V | X 2 1,5 | 8,9 | 146 |
| ÖPVC-JB/OB-YSY 300/500 V | 3G 1,5 | 9,3 | 157 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 1,5 | 9,9 | 180 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 1,5 | 10,8 | 216 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 1,5 | 11,9 | 264 |
| ÖPVC-JB/OB-YSY 300/500 V | 12G 1,5 | 15,1 | 434 |
| ÖPVC-JB/OB-YSY 300/500 V | X 2 2,5 | 10,4 | 185 |
| ÖPVC-JB/OB-YSY 300/500 V | 3G 2,5 | 11 | 213 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 2,5 | 11,9 | 253 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 2,5 | 12,8 | 301 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 2,5 | 14,3 | 410 |
| ÖPVC-JB/OB-YSY 300/500 V | 12G 2,5 | 18 | 650 |
| ÖPVC-JB/OB-YSY 300/500 V | X 2 4 | 12,5 | 329 |
| ÖPVC-JB/OB-YSY 300/500 V | 3G 4 | 12,6 | 343 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 4 | 13,9 | 357 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 4 | 15 | 504 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 4 | 16,4 | 640 |
| ÖPVC-JB/OB-YSY 300/500 V | 3G 6 | 15,5 | 450 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 6 | 15,8 | 495 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 6 | 17,2 | 592 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 6 | 18,9 | 845 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 10 | 19,4 | 1153 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 10 | 21,5 | 1352 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 10 | 23,4 | 1551 |
| ÖPVC-JB/OB-YSY 300/500 V | 4G 16 | 22,9 | 1360 |
| ÖPVC-JB/OB-YSY 300/500 V | 5G 16 | 24,6 | 1740 |
| ÖPVC-JB/OB-YSY 300/500 V | 7G 16 | 27,2 | 2166 |
| ÖPVC-JB/OB-YSY 0,6/1 kV | 3G 25 | 26,2 | 1630 |
| ÖPVC-JB/OB-YSY 0,6/1 kV | 4G 25 | 28,9 | 2020 |
| ÖPVC-JB/OB-YSY 0,6/1 kV | 5G 25 | 31,8 | 2465 |
| ÖPVC-JB/OB-YSY 0,6/1 kV | 4G 35 | 32,2 | 2570 |
| ÖPVC-JB/OB-YSY 0,6/1 kV | 5G 35 | 36 | 3185 |
| ÖPVC-JB/OB-YSY 0,6/1 kV | 4G 50 | 38,2 | 3515 |
| ÖPVC-JB/OB-YSY 0,6/1 kV | 4G 70 | 43,8 | 4810 |
| ÖPVC-JB/OB-YSY 0,6/1 kV | 4G 95 | 50,4 | 6360 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.