Power and Control Cable; 300/500V; 2 to 50 conductors; max. 95,00mm²; PVC/PVC, Flame and oil resistant; +80°C

PVC Control/Command Cable JZ/OZ YSY

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

Green Way Terra Protection?

Configure one of the cable wires to be green for grounding. The value will be updated in the cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Shielded Control Cable for Maximum Protection and PerformanceDesigned for the most demanding industrial conditions, this control and power cable offers maximum safety and performance. Its superior construction with triple shielding ensures the integrity of your systems and the continuity of your valuable operations.
  • Superior Mechanical Protection: Triple-layered steel mesh armor to withstand severe impacts and crushing.
  • High Chemical Resistance: Highly resistant to oils, acids and bases, ideal for harsh industrial environments.
  • Enhanced Fire Safety: Self-extinguishing and flame-retardant compound that enhances the protection of your property and team.
  • Versatility of Application: Perfect for fixed or flexible installations in dry, damp, and wet locations.
  • Reliable and Secure Signal: Magnetic shielding and pure copper conductors ensure interference-free data and power transmission.
PRODUCT DESIGN
  • Conductor material: bare copper wires
  • Conductor class: according to IEC 60228 cl. 5
  • Core insulation: PVC
  • Core identification: JZ/OZ: according to DIN VDE 0293, black cores with white numerals.
  • Braided: layered braiding
  • Inner cover material: PVC
  • Overall shielding: galvanized steel wire mesh
  • Outer cover material: PVC
  • Cover color: transparent
DETAILS

Benefits

  • Superior mechanical protection: The robust steel mesh protects against impacts and rodents.
  • High chemical resistance: PVC coating resistant to oils, acids and bases.
  • Enhanced Security: Self-extinguishing and flame-retardant material according to IEC 60332-1.
  • Versatile installation: Suitable for dry, humid, and wet environments.
  • Reliable connection: High insulation resistance of at least 20 MΩ x km.
  • Magnetic shielding: The steel braid offers protection against electromagnetic interference.
  • Wide temperature range: Safe operation in fixed installations from -30°C to +80°C.
  • Reinforced structure: Triple protection for high mechanical demands and greater durability.
  • Application flexibility: Ideal for fixed installations or flexible, voltage-free applications.
  • High dielectric strength: It supports a test voltage of 4 kV, ensuring greater electrical safety.

Applications

  • Electrical installations: As a power, control and connection cable in industrial plants.
  • Machines and tools: Connection in equipment that requires high mechanical protection.
  • Production lines: For fixed and flexible installations without defined routing.
  • Construction: For indoor use or with UV protection in outdoor areas.
  • Automation systems: Power supply and control of components in electrical panels.
  • Process industry: In locations where oils and other chemical agents are present.
  • Areas at risk of impact: Where physical protection of the cable is an essential requirement.
  • Workshop equipment: For connecting machines in dry, damp, or wet environments.
  • Control panels: Connection of controls, signaling and measurement circuits.
  • Engineering projects: Robust solution for applications requiring shielding.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typePVC control cable with steel braid for power, control and connection.
CórdobaÖPVC-JZ/OZ-YSY
Electrical Parameters
Nominal VoltageJZ/OZ: 300/500 V
Test Voltage4 kV
Conductor ResistanceAccording to IEC 60228 cl. 5
Insulation ResistanceMinimum 20 MΩ x km
Current CapacityAccording to DIN VDE, see technical guidelines.
Product Design
Conductor MaterialBare copper wires.
Driver ClassAccording to IEC 60228 class 5.
Vein IsolationPVC.
Road IdentificationJZ/OZ: black wires with white numbering; JB/OB: colored up to 5 wires (DIN 293-308), from 6 wires onwards, color code TKD. G: with earth conductor (GNYE).
Type of TwistTwisted veins in layers.
Inner Cover MaterialPVC.
shieldingBraided galvanized steel wire.
Exterior Roofing MaterialPVC.
Cover ColorTransparent.
Product characteristics
Application AreaElectrical installations, fixed installations, and flexible applications without tensile stress. Suitable for dry, damp, and wet environments.
Special featuresTriple protection for high mechanical demands and magnetic shielding.
For continuous bendingYes, for flexible applications with no defined route and no traction effort.
Minimum Radius of Curvature (Fixed)6 x cable diameter.
Minimum Radius of Curvature (Mobile)15 x cable diameter.
Temperature, fixed installation-30 °C to +80 °C.
Temperature, constant movement-15 °C to +70 °C.
Maximum temperature in the driver+70 °C (in operation); +150 °C (short-circuit).
Behavior in FireSelf-extinguishing and flame retardant according to IEC 60332-1.
UV resistantFor external use only with UV protection.
Chemical resistantHighly resistant to acids, bases, and specified oil types.
Standards and Approvals
RulesSimilar to EN 50525-2-51; IEC 60228 cl. 5; IEC 60332-1.
ApprovalsCE, EAC.
CPR (Construction Products Regulation)Class Eca.
DIMENSIONAL TABLE
TypeDimensãoExternal Diameter [mm]Weight [kg/km]
ÖPVC-JZ/OZ-YSY 300/500 V3G 2,511191
ÖPVC-JZ/OZ-YSY 300/500 V4G 2,511,9224
ÖPVC-JZ/OZ-YSY 300/500 V5G 2,512,8275
ÖPVC-JZ/OZ-YSY 300/500 V7G 2,514,3329
ÖPVC-JZ/OZ-YSY 300/500 V12G 2,518,2532
ÖPVC-JZ/OZ-YSY 300/500 V18G 2,521,1790
ÖPVC-JZ/OZ-YSY 300/500 V25G 2,524,41030
ÖPVC-JZ/OZ-YSY 300/500 V3G 412,6270
ÖPVC-JZ/OZ-YSY 300/500 V4G 413,9318
ÖPVC-JZ/OZ-YSY 300/500 V5G 415392
ÖPVC-JZ/OZ-YSY 300/500 V7G 416,4486
ÖPVC-JZ/OZ-YSY 300/500 V4G 615,8440
ÖPVC-JZ/OZ-YSY 300/500 V5G 617,2545
ÖPVC-JZ/OZ-YSY 300/500 V7G 618,9668
ÖPVC-JZ/OZ-YSY 300/500 V4G 1019,4699
ÖPVC-JZ/OZ-YSY 300/500 V5G 1021,5850
ÖPVC-JZ/OZ-YSY 300/500 V7G 1023,41189
ÖPVC-JZ/OZ-YSY 300/500 V4G 1622,41228
ÖPVC-JZ/OZ-YSY 300/500 V5G 1624,61322
ÖPVC-JZ/OZ-YSY 300/500 V7G 1627,21631
ÖPVC-JZ/OZ-YSY 300/500 V5G 2528,91591
ÖPVC-JZ/OZ-YSY 300/500 V5G 2531,81971
ÖPVC-JZ/OZ-YSY 300/500 V4G 3532,22099
ÖPVC-JZ/OZ-YSY 300/500 V5G 35362568
ÖPVC-JZ/OZ-YSY 300/500 V4G 5038,23099
ÖPVC-JZ/OZ-YSY 300/500 V4G 7043,74120
ÖPVC-JZ/OZ-YSY 300/500 V4G 9550,44780
ÖPVC-JZ/OZ-YSY 300/500 VX 2 0,57,177
ÖPVC-JZ/OZ-YSY 300/500 V3G 0,57,788
ÖPVC-JZ/OZ-YSY 300/500 VX 4 0,58,1101
ÖPVC-JZ/OZ-YSY 300/500 V4G 0,58,1101
ÖPVC-JZ/OZ-YSY 300/500 V5G 0,58,6116
ÖPVC-JZ/OZ-YSY 300/500 V7G 0,59,7134
ÖPVC-JZ/OZ-YSY 300/500 V12G 0,511,1205
ÖPVC-JZ/OZ-YSY 300/500 V12G 0,511,6205
ÖPVC-JZ/OZ-YSY 300/500 V14G 0,512,5242
ÖPVC-JZ/OZ-YSY 300/500 V18G 0,513,5266
ÖPVC-JZ/OZ-YSY 300/500 V21G 0,514,9332
ÖPVC-JZ/OZ-YSY 300/500 V25G 0,515,6345
ÖPVC-JZ/OZ-YSY 300/500 V30G 0,516,3450
ÖPVC-JZ/OZ-YSY 300/500 VX 2 0,757,888
ÖPVC-JZ/OZ-YSY 300/500 V3G 0,758,1102
ÖPVC-JZ/OZ-YSY 300/500 V4G 0,758,6135
ÖPVC-JZ/OZ-YSY 300/500 V5G 0,759,4144
ÖPVC-JZ/OZ-YSY 300/500 V7G 0,7510,3168
ÖPVC-JZ/OZ-YSY 300/500 V9G 0,7512,2219
ÖPVC-JZ/OZ-YSY 300/500 V12G 0,7512,8252
ÖPVC-JZ/OZ-YSY 300/500 V18G 0,7514,8330
ÖPVC-JZ/OZ-YSY 300/500 V21G 0,7516,2415
ÖPVC-JZ/OZ-YSY 300/500 V25G 0,7517435
ÖPVC-JZ/OZ-YSY 300/500 V34G 0,7519,3575
ÖPVC-JZ/OZ-YSY 300/500 V50G 0,7522,5896
ÖPVC-JZ/OZ-YSY 300/500 VX 2 18,2101
ÖPVC-JZ/OZ-YSY 300/500 V3G 18,5112
ÖPVC-JZ/OZ-YSY 300/500 V4G 19,3127
ÖPVC-JZ/OZ-YSY 300/500 V5G 19,8153
ÖPVC-JZ/OZ-YSY 300/500 V7G 111188
ÖPVC-JZ/OZ-YSY 300/500 V12G 113,6285
ÖPVC-JZ/OZ-YSY 300/500 V18G 115,6400
ÖPVC-JZ/OZ-YSY 300/500 V20G 116,8493
ÖPVC-JZ/OZ-YSY 300/500 V25G 118,1520
ÖPVC-JZ/OZ-YSY 300/500 V34G 120,5707
ÖPVC-JZ/OZ-YSY 300/500 V36G 120,5756
ÖPVC-JZ/OZ-YSY 300/500 VX 2 1,58,9117
ÖPVC-JZ/OZ-YSY 300/500 V3G 1,59,3137
ÖPVC-JZ/OZ-YSY 300/500 V4G 1,59,9167
ÖPVC-JZ/OZ-YSY 300/500 V5G 1,510,8193
ÖPVC-JZ/OZ-YSY 300/500 V7G 1,511,9228
ÖPVC-JZ/OZ-YSY 300/500 V8G 1,513,6285
ÖPVC-JZ/OZ-YSY 300/500 V12G 1,515,1378
ÖPVC-JZ/OZ-YSY 300/500 V18G 1,517,3480
ÖPVC-JZ/OZ-YSY 300/500 V25G 1,520,3685
ÖPVC-JZ/OZ-YSY 300/500 V34G 1,522,9870
ÖPVC-JZ/OZ-YSY 300/500 V41G 1,524,91101
ÖPVC-JZ/OZ-YSY 300/500 V42G 1,524,91211
ÖPVC-JZ/OZ-YSY 300/500 V50G 1,527,11355
ÖPVC-JZ/OZ-YSY 300/500 VX 2 2,510,4187
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.