Instrumentation and Fire Control Cable; Shielded; 600 V; 1 pair; max. 2,50 mm²; PVC/PVC, Flame Retardant; +70°C

Fire Cable Insulated Tape (BF) – 600V – NBR 17240

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Fire Alarm BF Cable: Maximum Security for your Detection SystemDesigned for critical fire alarm installations, this cable ensures uninterrupted and reliable communication. Its superior construction offers essential protection to preserve lives and property, rigorously complying with NBR 17240 standards and guaranteeing maximum performance.
  • Superior Electromagnetic Protection: Collective shielding with aluminized polyester tape that eliminates external interference and crosstalk.
  • Guaranteed Flame Retardant Safety: A flame-retardant and self-extinguishing compound that does not propagate fire, increasing environmental safety.
  • Flexible and Ultra Resistant: Excellent flexibility and high resistance to moisture, chemicals, and UV rays for long-lasting installations.
  • Critical and Versatile Applications: Ideal for sensors, smoke detectors, emergency lighting, and intrusion security systems.
  • Pure Signal Transmission: Seamless handling of digital and analog signals, ensuring that the alert always reaches its destination.
PRODUCT DESIGN
  • Stranded conductor made of bare electrolytic copper wires, soft temper, stranding class 2 NBR NM 280.
  • Insulation made of thermoplastic compound based on polyvinyl chloride (PVC/A) 70º C.
  • Meeting of drivers in pairs or trios.
  • Pair: Black / Red.
  • Suit: Black / Red / White
  • Twist pitch: 50 to 65mm
  • Separator made of polyester tape and collective shielding made of aluminized polyester tape, with a flexible drain conductor of 0,5 mm² cross-section, formed by tinned electrolytic copper wires.
  • Thermoplastic compound coating based on polyvinyl chloride (PVC/E) 105º C in Red color.
DETAILS

Benefits

  • Superior Protection: Efficient collective shielding against electromagnetic interference.
  • Healthy Signal: Maximum immunity against crosstalk, guaranteeing communication.
  • High Flexibility: It facilitates installation in ducts and locations with sharp bends.
  • Flame Retardant Safety: Self-extinguishing compound that does not spread flames in case of fire.
  • Environmental Resistance: Coverage with protection against chemicals, moisture, and UV rays.
  • Compliance Assured: Designed to meet all the requirements of the NBR 17240 standard.
  • Wide Voltage: 600V insulation voltage, offering greater robustness and electrical safety.
  • Thermal Performance: Outer casing resistant to operating temperatures up to 105°C.
  • Effective Grounding: Drain conductor that ensures the continuity and efficiency of the shielding.
  • Reliable Signage: Ideal for transmitting analog and digital signals without loss.

Applications

  • Fire alarm: Fixed installations in fire detection and alarm systems.
  • Industrial Instrumentation: Point-to-point transmission of analog (4-20mA) and digital signals.
  • Sensors and Meters: Connection of smoke detectors, meters and various sensors.
  • Emergency Lighting: Power supply and control in emergency lighting systems.
  • Hart® Communication: Data transmission in systems that use the Hart® protocol.
  • Building Automation: Power supply for conventional and electronic relays in buildings.
  • Security Systems: Used in security systems for intrusion prevention and surveillance.
  • Distance Measurement: Reliable connections for remote measurement and control systems.
  • Industrial Plants: General application in industrial environments for safety systems.
  • Commercial Buildings: Shopping malls, hospitals, hotels, and other high-traffic areas.
TECHNICAL DATA

 

General information
BrandINNOVCABLE
CórdobaFIRE ALARM BF – 600V – NBR 17240
Product typeCable for fixed installations of fire alarm and detection systems.
Electrical Parameters
Insulation Voltage600V
Test Voltage (Sparking)5,0 kVAC or 6,0 kVAC (depending on the section)
Electrical Resistance of the ConductorAccording to NBR NM 280 (at 20°C)
Insulation ResistanceAccording to the manufacturer's table (MΩ/Km at 500V min.)
Product Design
Conductor MaterialBare electrolytic copper wires, soft temper.
Driver ClassClass 2, according to NBR NM 280.
TrainingConductors grouped in pairs or trios.
Twisting Step50 to 65 mm
SeparatorPolyester tape.
shieldingCollective tape made of aluminized polyester.
Drain PipeFlexible, made of tinned electrolytic copper (0,5 mm² cross-section).
Vein Isolation MaterialThermoplastic compound based on polyvinyl chloride (PVC/A).
Exterior Roofing MaterialThermoplastic compound based on polyvinyl chloride (PVC/E).
Cover ColorRed.
Road IdentificationBy color.
Road Color CodePair: Black / Red; Suit: Black / Red / White
Product characteristics
Application AreaFixed installations of fire alarm systems, analog and digital signal transmission, instrumentation, Hart® protocol, sensor connections, relay power supply, security systems, and emergency lighting.
Maximum Temperature in the Conductor70 °C in continuous mode.
Maximum Temperature on the Roof
Protection against interferenceYes, protection against external electromagnetic interference and immunity to crosstalk.
FlexibilityExcellent flexibility.
Flame RetardantYes, it is flame retardant and self-extinguishing.
Flame Propagation TestComplies with NBR NM IEC 60332-3-23, category B.
UV resistantYes.
Moisture ResistantYes.
Chemical ResistantYes.
Halogen-freeNo (standard PVC version). Can be manufactured in LSZH upon request.
Optional configurations (upon request)
ConductorTinned copper, string classes 1, 4 or 5.
TrainingTraining on the Court.
Insulation Voltage300V, 750V or 0,6/1kV.
Vein IsolationPVC/E (105°C), XLPE (90°C or 125°C), HEPR (90°C), PE (80°C).
Roofing MaterialPE, PVC/ST1, PVC/ST2, special PVC (oil and grease resistant), LSZH (non-halogenated).
Special ApplicationsCylindrical cover for use with cable glands in classified areas (Ex).
Applicable Standards
HomeNBR 17240 - Fire detection and alarm systems.
Construction and TestingNBR 6148, NBR NM 280, NBR 6880.
Installation and SystemsNBR 9441, NBR 10898, NBR 13848, NBR 11836.
Fire SafetyNBR NM IEC 60332-3-23 (flame propagation).

 

DIMENSIONAL TABLE

 

Section (mm²)Nominal WireOhmic Resistance (Ω/Km max.)Insulation Resistance (MΩ/Km at 500V min.)Sparking (KVAC)Nominal InsulationNominal Thicknessø Nominal CoverageWeight (net/km)
0.3064362.2084.45.01.840.604.9032.0
0.5081335.0072.75.02.010.605.1037.0
0.751.02424.8062.45.02.220.605.5045.0
1.001.15018.2057.45.02.350.605.9052.0
1.351.29013.8052.85.0----
1.501.38012.2050.25.02.490.606.3059.0
2.5015 x 0.4558.2145.96.02.580.606.6064.0
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.