- Superior Electromagnetic Protection: Collective shielding with aluminized polyester tape that eliminates external interference and crosstalk.
- Guaranteed Flame Retardant Safety: A flame-retardant and self-extinguishing compound that does not propagate fire, increasing environmental safety.
- Flexible and Ultra Resistant: Excellent flexibility and high resistance to moisture, chemicals, and UV rays for long-lasting installations.
- Critical and Versatile Applications: Ideal for sensors, smoke detectors, emergency lighting, and intrusion security systems.
- Pure Signal Transmission: Seamless handling of digital and analog signals, ensuring that the alert always reaches its destination.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | INNOVCABLE |
| Córdoba | FIRE ALARM BF – 600V – NBR 17240 |
| Product type | Cable for fixed installations of fire alarm and detection systems. |
| Electrical Parameters | |
| Insulation Voltage | 600V |
| Test Voltage (Sparking) | 5,0 kVAC or 6,0 kVAC (depending on the section) |
| Electrical Resistance of the Conductor | According to NBR NM 280 (at 20°C) |
| Insulation Resistance | According to the manufacturer's table (MΩ/Km at 500V min.) |
| Product Design | |
| Conductor Material | Bare electrolytic copper wires, soft temper. |
| Driver Class | Class 2, according to NBR NM 280. |
| Training | Conductors grouped in pairs or trios. |
| Twisting Step | 50 to 65 mm |
| Separator | Polyester tape. |
| shielding | Collective tape made of aluminized polyester. |
| Drain Pipe | Flexible, made of tinned electrolytic copper (0,5 mm² cross-section). |
| Vein Isolation Material | Thermoplastic compound based on polyvinyl chloride (PVC/A). |
| Exterior Roofing Material | Thermoplastic compound based on polyvinyl chloride (PVC/E). |
| Cover Color | Red. |
| Road Identification | By color. |
| Road Color Code | Pair: Black / Red; Suit: Black / Red / White |
| Product characteristics | |
| Application Area | Fixed installations of fire alarm systems, analog and digital signal transmission, instrumentation, Hart® protocol, sensor connections, relay power supply, security systems, and emergency lighting. |
| Maximum Temperature in the Conductor | 70 °C in continuous mode. |
| Maximum Temperature on the Roof | |
| Protection against interference | Yes, protection against external electromagnetic interference and immunity to crosstalk. |
| Flexibility | Excellent flexibility. |
| Flame Retardant | Yes, it is flame retardant and self-extinguishing. |
| Flame Propagation Test | Complies with NBR NM IEC 60332-3-23, category B. |
| UV resistant | Yes. |
| Moisture Resistant | Yes. |
| Chemical Resistant | Yes. |
| Halogen-free | No (standard PVC version). Can be manufactured in LSZH upon request. |
| Optional configurations (upon request) | |
| Conductor | Tinned copper, string classes 1, 4 or 5. |
| Training | Training on the Court. |
| Insulation Voltage | 300V, 750V or 0,6/1kV. |
| Vein Isolation | PVC/E (105°C), XLPE (90°C or 125°C), HEPR (90°C), PE (80°C). |
| Roofing Material | PE, PVC/ST1, PVC/ST2, special PVC (oil and grease resistant), LSZH (non-halogenated). |
| Special Applications | Cylindrical cover for use with cable glands in classified areas (Ex). |
| Applicable Standards | |
| Home | NBR 17240 - Fire detection and alarm systems. |
| Construction and Testing | NBR 6148, NBR NM 280, NBR 6880. |
| Installation and Systems | NBR 9441, NBR 10898, NBR 13848, NBR 11836. |
| Fire Safety | NBR NM IEC 60332-3-23 (flame propagation). |
| Section (mm²) | Nominal Wire | Ohmic Resistance (Ω/Km max.) | Insulation Resistance (MΩ/Km at 500V min.) | Sparking (KVAC) | Nominal Insulation | Nominal Thickness | ø Nominal Coverage | Weight (net/km) |
| 0.30 | 643 | 62.20 | 84.4 | 5.0 | 1.84 | 0.60 | 4.90 | 32.0 |
| 0.50 | 813 | 35.00 | 72.7 | 5.0 | 2.01 | 0.60 | 5.10 | 37.0 |
| 0.75 | 1.024 | 24.80 | 62.4 | 5.0 | 2.22 | 0.60 | 5.50 | 45.0 |
| 1.00 | 1.150 | 18.20 | 57.4 | 5.0 | 2.35 | 0.60 | 5.90 | 52.0 |
| 1.35 | 1.290 | 13.80 | 52.8 | 5.0 | - | - | - | - |
| 1.50 | 1.380 | 12.20 | 50.2 | 5.0 | 2.49 | 0.60 | 6.30 | 59.0 |
| 2.50 | 15 x 0.455 | 8.21 | 45.9 | 6.0 | 2.58 | 0.60 | 6.60 | 64.0 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.