Control and Communication Cable; 0,6/1 kV; 1 to 52 pairs; max. 0,80 mm²; Mica / LSZH / LSZH, Fire Resistant; +70°C
Fire Cable Instrumentation Shielded Tape (BF) JE-H(St)H FE180 E30-E90 – IEC60331 – Fire Resistant
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Extreme Fire Resistance: Keeps systems running for up to 90 minutes (E90) under direct fire, ensuring safe evacuations.
- Maximum Human Safety: LSZH (halogen-free) technology that does not emit toxic fumes, preserving lives during evacuation.
- Reliable and Flawless Communication: Electrostatic shielding that protects against interference, ensuring the transmission of vital data and commands.
- Ideal for Critical Environments: Essential for hospitals, industries, and places with large concentrations of people and property.
- Investing in Peace of Mind: The smart choice that goes beyond the norm, representing the highest level of protection and security for your project.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | INNOVCABLE |
| Product type | Halogen-free installation cable for industrial electronics, with improved fire resistance (INNOVCABLE EXTREME FIRE RESISTANT JE-H(St)H FE180 E30-E90). |
| Electrical Parameters | |
| Operating Voltage | Max. 225 V |
| Test Voltage | Conductor/Conductor: 500 V | Conductor/Outer Sheath: 2000 V |
| Circuit Resistance (at 20°C) | Max. 73,2 Ω/km |
| Insulation Resistance | Min. 100 MΩxkm |
| Mutual Capacitance (at 800 Hz) | Max 120 nF/km (or max 200 pF/100m) |
| Inductance | Approx. 0,65 mH/km |
| Linear Attenuation (at 800 Hz) | Approx. 1,2 dB/km |
| Product Design | |
| Conductor Material | Solid copper 0,8 mm Ø (tin-plated copper available upon request). |
| Vein Isolation | Isolated mica ceramic with a cross-linked, halogen-free, LSZH polymer compound. |
| Type of Twist | Two conductors forming a pair; four pairs forming a bundle; bundles mounted in layers. |
| Separating Tape | Helically applied polyester tape. |
| Shielded | Yes, shielding with aluminized polyester tape + 0,8 mm Ø drain wire. |
| Cable Format | Round |
| Outer Cover Material | Halogen-free polymeric compound LSZH. |
| Cover Color | Orange (or Red when BMK). |
| Identification of the Lanes (Pairs) | Pair 1: blue - red; Pair 2: gray - yellow; Pair 3: green - brown; Pair 4: white - black. |
| Beam Identification | The individual bundles are identified by numbered tape. |
| Product characteristics | |
| Application Area | Fixed installation in dry or damp locations for measurement, data and control systems in industrial electronics, especially where people and property need protection in case of fire. |
| Fire resistance | The insulation remains compact under flame for 180 minutes (FE180). |
| Circuit Integrity | E30: 30 minutes (alarm systems, panic lighting, evacuation). E90: 90 minutes (fire suppression systems, emergency elevators). |
| Temperature, installation | -5 °C to +50 °C. |
| Temperature, fixed installation | -30 °C to +70 °C. |
| Halogen-free | Yes. |
| Use Restrictions | It should not be applied directly to soil or water, nor in outdoor areas without adequate protection from sunlight. Not intended for power supply. |
| Applicable Standards | |
| DIN VDE 0815 | IEC 60331 |
| DIN VDE 0472 part 814 | IEC 60332-1 |
| DIN VDE 4102 part 12 | IEC 60332-3 |
| IEC 60754-1 | IEC 60754-2 |
| IEC 61034-2 | - |
| Number of conductors x conductor diameter | External Diameter | Insulation thickness | Fire load | Weight of the Ass | Cable Weight |
| approx. | nominal | approx. | |||
| N x mm² | mm | mm | kWh/year | kg/km | kg/km |
| 1 x 2 x 0,8 | 5,5 | 0,3 | 0,095 | 15 | 40 |
| 2 x 2 x 0,8 | 6 | 0,3 | 0,123 | 25 | 56 |
| 4 x 2 x 0,8 | 8,7 | 0,3 | 0,21 | 45 | 96 |
| 8 x 2 x 0,8 | 13,7 | 0,3 | 0,52 | 85 | 218 |
| 12 x 2 x 0,8 | 14,6 | 0,3 | 0,58 | 126 | 270 |
| 16 x 2 x 0,8 | 16 | 0,3 | 0,69 | 166 | 337 |
| 20 x 2 x 0,8 | 18 | 0,3 | 0,8 | 206 | 403 |
| 32 x 2 x 0,8 | 21,8 | 0,3 | 1,02 | 326 | 570 |
| 40 x 2 x 0,8 | 25,3 | 0,3 | 1,38 | 407 | 739 |
| 52 x 2 x 0,8 | 27,6 | 0,3 | 1,59 | 529 | 906 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.