Fire Instrumentation Cable; 300 V; 1 pair; max. 1,50 mm²; PVC/PVC, Flame Retardant; +70°C
Unshielded Fire Cable (SB) – 300V – NBR 17240
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Designed for Total Security: Fire-retardant and self-extinguishing construction that strictly complies with NBR 17240 standards.
- Maximum Durability and Resistance: Excellent flexibility and superior protection against moisture, UV rays and chemicals.
- Versatile and Reliable Connection: Ideal for analog and digital signals, sensors, meters, and emergency lighting systems.
- Upper Signal Conduction: Conductors made of pure electrolytic copper that guarantee data transmission with complete integrity.
- Practical and Secure Installation: Recommended for use in piping, ensuring greater mechanical protection and a safe, long-lasting installation.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | INNOVCABLE |
| Product type | Cable for fixed installations of fire alarm systems, analog and digital signal transmission, instrumentation, and security systems. |
| Córdoba | INNOVCABLE FIRE ALARM SB 300V NBR 17240 |
| Electrical Parameters | |
| Insulation Voltage | 300V |
| Routine Tests | Electrical resistance of the conductor at 20°C, Alternating current voltage, Insulation resistance. |
| Product Design | |
| Conductor Material | Bare electrolytic copper wires, soft temper. |
| Driver Design | Class 2 stringing, according to NBR NM 280. |
| Roadway Isolation | Thermoplastic compound based on polyvinyl chloride (PVC/A) 70°C. |
| Reunion Island | Conductors grouped in pairs or trios. |
| Twisting Step | 50 to 65mm. |
| Separator | Polyester tape. |
| Exterior Roofing Material | Thermoplastic compound based on polyvinyl chloride (PVC/A). |
| Cover Color | Red. |
| Road Color Code | Pair: Black / Red. Suit: Black / Red / White. |
| Product characteristics | |
| Application Area | Fire detection and alarm systems, signal transmission (4-20mA, digital), Hart® protocol, sensor and relay connections, intrusion security systems, and emergency lighting. |
| Recommended Installation | Fixed installations, which may be in galvanized steel piping. |
| Maximum Temperature in the Conductor | 70 °C in continuous mode. |
| Flexibility | Excellent flexibility. |
| Flame Retardant | Yes, it is flame retardant and self-extinguishing according to NBR NM IEC 60332-3-23, category B. |
| UV resistant | Yes. |
| Chemical Resistant | Yes. |
| Moisture Resistant | Yes. |
| Halogen-free | No (standard PVC version). LSZH version available upon request. |
| Options Available Upon Request | |
| Conductor | Tinned copper; String classes 1, 4 or 5. |
| Training | quadra. |
| Insulation (Other Temperatures) | PVC/E (105°C), XLPE (90°C or 125°C), HEPR (90°C), PE (80°C). |
| Cover and Cover (Other Materials) | PE, PVC/ST1, PVC/ST2, special oil-resistant PVC, LSZH. |
| Special Coverage | Perfectly cylindrical cover for use with cable glands in classified areas (Ex). |
| Insulation Voltage | 750V or 0,6/1kV. |
| Applicable Standards | |
| NBR 17240 | Fire detection and alarm systems - Design, installation, commissioning and maintenance. |
| NBR NM 280 | Insulated cable conductors. |
| NBR 6148 | Insulated conductors with extruded polyvinyl chloride (PVC) insulation. |
| NBR 6880 | Copper conductors for insulated cables. |
| NBR 9441 | Installation of fire detection and alarm systems. |
| NBR NM IEC 60332-3-23 | Vertical flame propagation test. |
| Dimensional Data (Examples) | |
| Gauge (mm²) | Nominal Outside Diameter (mm) |
| 1P x 0.32 | 4.60 |
| 1P x 0.50 | 4.80 |
| 1P x 0.75 | 5.30 |
| 1P x 1.00 | 5.60 |
| 1P x 1.50 | 6.30 |
| Gauge (mm²) | Nominal Insulation | Nominal Thickness | ø Nominal Coverage | Net weight/km |
| 1Px0.32 | 1.64 | 0.40 | 4.60 | 33.0 |
| 1Px0.50 | 1.80 | 0.40 | 4.80 | 38.0 |
| 1Px0.75 | 2.0 | 0.40 | 5.30 | 41.0 |
| 1Px1.00 | 2.15 | 0.40 | 5.60 | 47.0 |
| 1Px1.50 | 2.38 | 0.40 | 6.30 | 59.0 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.