Instrumentation and Control Cable; Shielded; Armored; 500V; 1 to 24 pairs; max. 2,50mm², Numbered Pairs; LSZH, XLPE / PVC / PVC, Flame Resistant; +90°C

Instrumentation Cable RE-2X(St)2YSWAY-fl PiMf Intrinsically Safe

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Shielded and Armored Instrumentation Cable for Secure and Reliable ConnectionsDesigned for transmitting analog or digital signals in control systems, this cable offers superior protection. Its robust construction with a steel armor and individual shielding ensures complete data integrity, even in the harshest environments.
  • Pure Signal with No Interference: Individual shielding per pair and collective shielding for maximum electromagnetic protection.
  • Superior Mechanical Protection: Armor made of galvanized steel wire to protect against impacts, crushing, and even rodents.
  • High Safety and Durability: XLPE insulation and flame-retardant PVC outer covering.
  • Versatility of Application: Ideal for indoor and outdoor environments, ensuring consistent performance.
  • Long-Term Reliability: Built to operate in wide temperature ranges, ensuring the continuity of your process.
PRODUCT DESIGN
  • Conductor: Bare, electrolytic, stranded, annealed copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and/or tinned upon request)
  • Insulation: XLPE compound to EN50290-2-29 Twisted pairs in Black/White with numbered cores
  • Bonding Tape: Polyester tape on each twisted pair
  • Individual Shielding: Aluminum/polyester tape with a tinned copper drain wire in direct contact with the metallic side of the tape.
  • Bonding Tape: Polyester tape over the overall core of the cable, which is formed by twisted pairs.
  • Collective Shielding: Aluminum/polyester tape with a tinned copper drain wire in direct contact with the metallic side of the tape.
  • Inner Cover: PVC compound to EN50290-2-22
  • Armor: Round galvanized steel wires to EN 10257-1
  • Outer Sheath: Flame-retardant PVC compound to EN50290-2-22. Blue for intrinsically safe cable. Black for UV resistant and/or non-intrinsically safe cable. Other colors available upon request.
DETAILS

Benefits

  • Superior Mechanical Protection: Galvanized steel wire reinforcement that offers maximum resistance against impacts and crushing.
  • Pure Signal Transmission: Individual pair shielding (PIMF) and collective shielding, ensuring complete protection against electromagnetic interference (EMC).
  • High Durability: Robust, flame-retardant PVC covering, ideal for harsh industrial environments.
  • Enhanced Security: Construction in accordance with IEC 60332-1-2 and IEC 60332-3-24 Cat C standards, for enhanced fire safety.
  • Operation in Extreme Climates: Wide operating temperature range, from -40°C to +90°C, ensuring performance in harsh conditions.
  • Trust Isolation: XLPE insulation provides excellent electrical characteristics and superior thermal resistance.
  • Installation Versatility: Suitable for indoor and outdoor use, it can be installed in trays or buried directly.
  • Optional Chemical Resistance: Available in oil- and hydrocarbon-resistant versions for special applications.
  • Secure and Stable Connection: Electrolytic bare copper conductors that ensure optimal conductivity and reliability in the connection.
  • Certified Quality: Developed and tested according to the stringent standards of the European standard EN 50288-7.

Applications

  • Automation Systems: Connection of instruments and control systems for analog or digital signal transmission.
  • Petrochemical Industry: Instrumentation circuits in refineries and chemical plants, where mechanical protection is essential.
  • Power Plants: Connecting measurement and control equipment in environments with high electromagnetic interference.
  • Process Control: Communication networks for controlling PLCs, flow, pressure, and temperature sensors.
  • Manufacturing and Production: Installations on factory floors that require a robust cable to protect control signals.
  • Treatment Plants: Monitoring and control circuits in water and wastewater treatment plants.
  • Mining Industry: Fixed applications in harsh environments, with exposure to dust, moisture and risk of mechanical damage.
  • Intrinsically Safe Areas: Used in safety circuits (blue-coated version) to prevent ignition in classified areas.
  • Infrastructure and Transportation: Control systems in ports, airports, and railways.
  • Paper and Pulp: Connecting sensors and actuators in industrial processes with chemically aggressive environments.
TECHNICAL DATA

 

General information
BrandINNOVCABLE
CórdobaRE-2X(St)YSWAY-fl PIMF
Product typeInstrumentation cable for analog or digital signal transmission, with individual pair shielding (PIMF), collective shielding, and steel wire armor.
Application AreaUsed to connect instruments and control systems in indoor and outdoor applications. Should not be connected directly to the mains power supply.
Electrical Parameters (at 20°C)
Nominal Voltage500 V AC (300 V version available upon request)
AC Test Voltage2000 V for 1 minute (via-via / via-shielding)
Conductor Resistance (max.)0,5mm²: 36,7 Ω/km | 0,75mm²: 25,0 Ω/km | 1mm²: 18,5 Ω/km | 1,3mm²: 14,2 Ω/km | 1,5mm²: 12,3 Ω/km | 2,5mm²: 7,6 Ω/km
Insulation Resistance (min.)5000 MΩ.km
Mutual Capacitance (max.)150 nF/km
Inductance (max.)1 mH/km
L/R ratio (max.)0,5-1mm²: 25 µH/Ω | 1,3-1,5mm²: 40 µH/Ω | 2,5mm²: 60 µH/Ω
Product Design
Conductor MaterialBare, annealed, and stranded copper wires.
Driver ClassClass 2 according to IEC 60228 (Class 1, 5 and/or tin-plated upon request).
Insulation MaterialComposed of XLPE according to EN 50290-2-29.
Road IdentificationBlack/White twisted pairs with numbered cores.
Individual ProtectionYes, aluminum/polyester tape with tinned copper drain wire for each pair (PIMF).
Collective ShieldingYes, aluminum/polyester tape with tinned copper drain wire.
Inner LayerPVC compound according to EN 50290-2-22.
ArmorRound galvanized steel wire conforming to EN 10257-1.
Outer Cover MaterialFlame retardant PVC compound in accordance with EN 50290-2-22.
Outer Cover ColorBlue (for intrinsically safe systems) or Black (UV resistant). Other colors available upon request.
Mechanical and Environmental Characteristics
Operating Temperature-40°C to +90°C
Installation Temperature-5°C to +50°C
Minimum Radius of Curvature (Fixed)10 x Cable Outer Diameter
Flame RetardantYes, in accordance with IEC 60332/1-2 and IEC 60332/3-24 Cat C.
UV resistantYes, in the version with the black outer cover.
Additional Resources (Upon Request)Oil resistance, hydrocarbon resistance, termite/rodent protection, LSF (low smoke emission) version.
Standards and Certifications
Construction StandardEN 50288-7
Electrical and Mechanical TestsEN 50289 series
Types of Materials and TestsEN 50290-2 series
CertificatesCE, RoHS, REACH, EAC
Physical characteristics
Cross SectionsAvailable in sizes from 2x2x0,5 mm² to 24x2x2,5 mm².
Nominal Outside DiameterIt varies from approximately 14,7 mm to 48,9 mm, depending on the formation.
Approximate weightIt varies from approximately 361 kg/km to 3804 kg/km, depending on the formation.

 

DIMENSIONAL TABLE
Nominal Outside Diameter (mm)Approximate Weight (kg/km)Conductor Resistance (max. Ω/km)Insulation Resistance (min. MΩ.km)Mutual Capacitance (max. nF/km)Inductance (max. mH/km)
L/R ratio (max. µH/Ω)
14,736136,75000150125
17,550836,75000150125
18,756036,75000150125
21,377536,75000150125
23,389036,75000150125
23,995036,75000150125
26,2111836,75000150125
28,6128136,75000150125
32166036,75000150125
15,8408255000150125
17,8521255000150125
19578255000150125
21761255000150125
23,2890255000150125
25,71043255000150125
26,41115255000150125
291323255000150125
32,61725255000150125
35,81998255000150125
16,242518,55000150125
18,555018,55000150125
19,561618,55000150125
21,881518,55000150125
23,895118,55000150125
26,5110818,55000150125
27,2119718,55000150125
29,8141518,55000150125
33,6183618,55000150125
37,2217018,55000150125
16,946012,35000150140
19,160412,35000150140
21,480512,35000150140
22,990212,35000150140
25,3106812,35000150140
28124012,35000150140
28,9134712,35000150140
32,3178512,35000150140
35,9212312,35000150140
39,4244112,35000150140
17,54907,65000150160
19,66307,65000150160
21,98507,65000150160
23,49407,65000150160
25,911147,65000150160
28,913087,65000150160
29,714217,65000150160
33,518837,65000150160
37,122607,65000150160
40,725937,65000150160
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.