Instrumentation and Control Cable; Shielded; Armored; 500V; 1 to 24 pairs; max. 2,50mm², Numbered Pairs; LSZH; XLPE / PVC / PVC, Flame Resistant; +90°C

Instrumentation Cable RE-2X(St)2YSWAY-fl Intrinsically Safe

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Armored Instrumentation Cable for Intrinsic Safety: Secure Connection for Industrial AutomationIdeal for transmitting analog and digital signals in control systems. This robust cable ensures the integrity of your data with maximum protection, making it the definitive choice for critical indoor or outdoor applications in any industry.
  • Superior Mechanical Protection: Armor made with galvanized steel wire that resists impacts and crushing in harsh environments.
  • Interference-Free Signal: Collective shielding blocks external noise, ensuring accurate and reliable data communication.
  • High Security: Featuring a flame-retardant PVC outer coating, it protects your installation against the spread of fire.
  • Performance in Extreme Temperatures: It operates with full efficiency from -40°C to +90°C, ideal for any environmental challenge.
  • Durability and European Standard: Built to EN 50288-7 standards, ensuring a high-quality investment and a long service life.
PRODUCT DESIGN
  • Conductor: Electrolytic bare copper wires, stranded, according to IEC 60228 Class 2 (Class 1 or Class 5 and/or tinned upon request).
  • Insulation: XLPE compound conforming to EN50290-2-29. Black/White twisted pairs with numbered wires.
  • Wrapping Tape: Polyester tape applied over the cable path formed by twisted pairs.
  • Collective Shielding: Aluminum/Polyester tape with tinned copper drain wire in direct contact with the metallic side of the tape.
  • Internal Covering: PVC compound.
  • Reinforcement: Round galvanized steel wires according to EN 10257-1.
  • Outer Sheath: Flame-retardant PVC compound conforming to EN50290-2-22. Blue color for intrinsically safe cables. Black color for UV-resistant and/or non-intrinsically safe cables. Other colors available upon request.
DETAILS

Benefits

  • Superior Mechanical Protection: Armor made of galvanized steel wire that protects against crushing and impacts.
  • Reliable Signal Transmission: Collective shielding with aluminum/polyester foil that prevents electromagnetic interference.
  • Enhanced Security: External PVC compound with flame-retardant properties, increasing operational safety.
  • Wide Temperature Range: Safe operation in adverse conditions, with a working temperature of -40°C to +90°C.
  • Resistance for Outdoor Environments: Black, UV-resistant outer covering, ideal for outdoor installations.
  • High Performance Insulation: XLPE insulation ensures excellent electrical properties and durability.
  • Compliance with Standards: Manufactured in accordance with EN 50288-7 standards, ensuring quality and reliability.
  • Easy Installation and Identification: Twisted pairs with numbered cores that simplify connection and maintenance.
  • Versatility of Use: Designed for efficient use in both indoor and outdoor applications.
  • High Durability: Robust construction that ensures a long service life, even in harsh industrial environments.

Applications

  • Industrial Automation: Connection of sensors, actuators, and programmable logic controllers (PLCs).
  • Process Control Systems: Transmission of analog and digital signals in industrial plants.
  • Petrochemical Industry: Used in refineries and chemical plants where mechanical robustness is essential.
  • Instrumentation Equipment: Connection of instruments for measuring flow, pressure, level, and temperature.
  • Power Generation Plants: Control and monitoring of equipment in power plants and substations.
  • Water Treatment Plants: Data transmission for pump control systems and quality sensors.
  • Mining and Cement Industry: Applications requiring high protection against abrasion and impacts.
  • Intrinsic Safety Systems: Ideal for safety circuits requiring low interference (blue version).
  • Control Panels and Centers: Interconnection of components in electrical panels and control rooms.
  • General Manufacturing: Communication between machines and supervisory systems in production lines.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product DesignationRE-2X(St)YSWAY-fl
Product typeInstrumentation and control cable, with collective shielding and armored, for analog or digital signal transmission.
Electrical Parameters
Nominal Voltage500 V AC
Test Voltage2000 V x 1 min. (via-via / via-shielding)
Conductor ResistanceMaximum of 7,6 to 36,7 Ω/km at 20°C, depending on the cross-section.
Insulation ResistanceMinimum of 5000 MΩxkm.
Mutual CapacitanceMaximum of 150 nF/km.
InductanceMaximum of 1 mH/km.
L/R ratioMaximum density of 25 to 60 µH/Ω, depending on the cross-sectional area.
Product Design
Conductor MaterialBare, annealed, and stranded copper wires (tin plating available upon request).
Driver ClassClass 2 according to IEC 60228 (Class 1 or 5 available upon request).
Vein Isolation MaterialComposed of XLPE according to EN 50290-2-29.
Road IdentificationBlack/White braided pairs, numbered.
Wiring TapePolyester tape over the overall core of the cable.
shieldingCollective shielding with aluminum/polyester tape and tinned copper drain wire.
Inner Cover MaterialPVC compound.
ArmorRound galvanized steel wires conforming to EN 10257-1.
Exterior Roofing MaterialFlame retardant PVC compound in accordance with EN 50290-2-22.
Cover ColorBlue (for intrinsically safe cables) or Black (for UV resistant cables). Other colors available upon request.
Product characteristics
Application AreaUsed to connect instruments and control systems for signal transmission in indoor and outdoor applications.
Restriction of UseIt should not be connected directly to the main power grid or other low-impedance sources.
Minimum Radius of Curvature (Fixed)10 x Outer Diameter.
Temperature, during operation-40 °C to +90 °C.
Temperature during installation-5 °C to +50 °C.
Flame retardantConforms to IEC 60332/1-2 and IEC 60332/3-24 Cat C.
UV resistantYes (for the black color coating). Available upon request for other colors.
Oil resistantAvailable upon request.
Other Features (upon request)Resistant to hydrocarbons, termite/rodent resistant, LSF version (low smoke and gas emission).
Applicable Standards and Certifications
ConstructionEN 50288-7
Electrical and Mechanical TestsEN 50289 series
Types of Materials and TestsEN 50290-2 series
ConductorIEC 60228
ArmorEN 10257-1
Flame RetardantIEC 60332/1-2, IEC 60332/3-24 Cat C
CertificatesCE, RoHS, REACH, EAC
DIMENSIONAL TABLE
Cross Sections (mm²)Nominal Outside Diameter (mm)
Approximate Weight (kg/km)
1x2x0.510,7218
2x2x0.513,4314
4x2x0.514,9384
5x2x0.515,8425
6x2x0.516,7465
8x2x0.518,3540
10x2x0.520,7728
12x2x0.521,4782
16x2x0.523,1900
20x2x0.525,31041
24x2x0.527,31163
1x2x0.7511,5252
2x2x0.7514,6360
4x2x0.7516,1443
5x2x0.7517,1490
6x2x0.7518,4548
8x2x0.7520,7748
10x2x0.7522,9875
12x2x0.7523,5930
16x2x0.7525,61084
20x2x0.7527,91253
24x2x0.7530,51428
1x2x111,7264
2x2x114,9377
4x2x116,5470
5x2x117,7530
6x2x118,9590
8x2x121,5820
10x2x123,5833
12x2x124,1998
16x2x126,41183
20x2x1291384
24x2x132,21753
1x2x1.312,1281
2x2x1.315,5409
4x2x1.317,5532
5x2x1.318,6592
6x2x1.319,8660
8x2x1.322,6910
10x2x1.324,81050
12x2x1.325,71152
16x2x1.327,91354
20x2x1.330,71587
24x2x1.334,72060
1x2x1.512,3291
2x2x1.515,9426
4x2x1.517,9556
5x2x1.519,1626
6x2x1.521811
8x2x1.523,2955
10x2x1.525,71126
12x2x1.526,41213
16x2x1.528,91444
20x2x1.532,31868
24x2x1.535,72190
1x2x2.513,5342
2x2x2.518530
4x2x2.521822
5x2x2.522,6934
6x2x2.524,21049
8x2x2.526,81251
10x2x2.529,81470
12x2x2.530,71621
16x2x2.534,82187
20x2x2.538,32570
24x2x2.5422960
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.