Instrumentation and Control Cable; Individual and collective shielding; 500V; 2 to 24 pairs; max. 1,30mm², Numbered Pairs; LSZH, XLPE / PVC, Flame resistance; +90°C

Instrumentation Cable RE-2X(St)Yv-fl PiMf Intrinsically Safe

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Instrumentation Cable for High-Performance SystemsDesigned for top performance in automation and data processing systems, this cable ensures the transmission of information with maximum fidelity and security, even in the most demanding environments, thanks to its superior construction and high-quality shielding.
  • Versatile and Safe Installation: It can be installed in dry or humid areas, outdoors, and even directly buried in the ground, offering maximum flexibility.
  • Interference-Free Transmission: High-quality shielding protects the signal against electromagnetic noise, ensuring the accuracy and integrity of your data.
  • Durability and Long Service Life: XLPE insulation and reinforced PVC cover for reliable and long-lasting operation, even under adverse conditions.
  • Resistance to Hostile Environments: Resistant to UV rays (black version) and extreme temperatures (-30 to +70°C), ideal for outdoor installations.
  • Fire Safety: Made with flame-retardant material (IEC 60332-3-24 Cat. C), which increases the safety of your entire installation.
PRODUCT DESIGN
  • Conductor material: bare copper wires
  • Conductor class: 7-wire construction according to IEC 60228 class 2
  • Core insulation: XLPE (cross-linked polyethylene)
  • Core identification: pairs: single color with numerals: core A black, core B: white; trio: core A: white, core B: red, core C: black, cores A and C with numerals
  • Stringing: layered braided pairs
  • Element shielding: foil-coated metal pairs (PiMf) with underlying 0,5 mm tinned drain wire.
  • Overall shielding: polyester-coated aluminum foil (24 μm) with underlying tinned drain wire of 0,5 mm² (7x0,30 mm)
  • Outer sheath material: PVC
  • Sheath color: black or blue RAL 5015 for intrinsically safe systems.
DETAILS

Benefits

  • Reliable data transmission: Ideal for data communication at rates up to 200 kBit/s in MSR and EDP systems.
  • High signal quality: The transmission characteristics are guaranteed by high-quality braiding and shielding.
  • Versatile installation: Suitable for fixed installation in dry and humid areas, outdoors, and direct burial in the ground.
  • Temperature resistance: It operates safely over a wide temperature range, from -30°C to +70°C in fixed installations.
  • Robust protection: The reinforced PVC coating and UV resistance (black version) ensure a long service life.
  • Fire safety: Flame retardant material in accordance with VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C).
  • Effective shielding: Shielding with plastic-coated aluminum foil and tinned copper drain wire protects against electromagnetic interference.
  • Excellent insulation: XLPE insulation that guarantees an insulation resistance of 1000 MOhmxkm.
  • Quality conductors: Bare copper conductor, class 2, with 7-wire construction for optimal conductivity.
  • Compliance with standards: Manufactured in accordance with EN 50288-7 standard, guaranteeing quality and safety.

Applications

  • Industrial automation systems: Data communication in process control and measurement (MSR) systems.
  • Data processing equipment: Signal transmission in electronic data processing (EDP) systems.
  • External facilities: Perfect for outdoor use due to its UV resistance and wide operating temperature range.
  • Underground applications: It can be buried directly in the ground, making it ideal for long-distance installations.
  • Humid industrial environments: Suitable for installation in damp locations, ensuring reliable operation.
  • Intrinsically safe circuits: Used in areas classified as Zone 1 and 2, Group II, to ensure safety in potentially explosive environments.
  • Control and instrumentation systems: Transmission of analog and digital signals in various control equipment.
  • Chemical and petrochemical plants: Resistant to harsh environments, making it a safe choice for these industries.
  • Machinery and equipment: Connection of sensors and actuators that require interference-free signal transmission.
  • Building infrastructure: Used in building management and automation systems for stable data communication.
TECHNICAL DATA
General information
BrandINNOVCABLE®
Product typeInstrumentation cable for transmitting analog and digital signals. Model RE-2X(St)Yv-fl PIMF.
Electrical Parameters
Nominal Voltage300 V (AC IEC)
Test Voltage1,5 kV
Conductor Resistance0.5mm²: max. 36.70 Ω/km; 0.75mm²: max. 25.00 Ω/km; 1.3mm²: max. 14.20 Ω/km
Insulation ResistanceMin. 5 GΩ x km
Current CapacityAccording to DIN VDE.
CapacitanceMax. 115 nF/km
InductanceApprox. 1 mH/km
Capacitive CouplingMax. 500 pF / 500 m
Product Design
Conductor MaterialBare copper wires.
Driver Design7-wire construction, in accordance with IEC 60228 class 2.
Includes protective conductor (ground).Not specified. It has a tinned copper drain wire under the shielding.
Type of TwistTwisted pairs in layers.
shieldingYes, individual and total armor.
Element-Based ShieldingPairs in metallic ribbon (PiMf) with 0.6mm tinned copper drain wire.
Full ArmorPlastic-coated aluminum tape (24 µm) with 0.5 mm² tinned copper drain wire.
Cable FormatRound
Base Material for Pathway IsolationXLPE (cross-linked polyethylene).
Base Material for the External CoveringPVC, robust and reinforced version.
Abbreviation for Roofing MaterialPVC
Cover ColorBlack or Blue (RAL 5015 for intrinsically safe systems).
Road IdentificationSingle color with printed numerals.
Road color codePairs: Black route A, white route B. Trios: White route A, red route B, black route C.
Product characteristics
Application AreaMeasurement and process control technology, intrinsically safe systems (zone 1 and 2, group II), installations in dry and wet locations, outdoor and underground use.
EMCYes.
For continuous bendingNot specified. Temperature range for operation defined.
Minimum Radius of Curvature7.5 x cable diameter (fixed installation).
Temperature, fixed installation-40 °C to +70 °C.
Temperature, in motion-5 °C to +50 °C.
Maximum temperature in the driver+90 °C.
Flame retardantYes, in accordance with IEC 60332-1-2 and IEC 60332-3-24 (Cat. C).
UV resistantYes, in accordance with UL 1581 Section 1200.
Chemical resistantHighly resistant to common acids, bases, and oils.
Halogen-freeNot specified (PVC roofing usually contains halogens).
Oil resistantYes, in accordance with ICEA S-73-532/NEMA WC 57-2004 § 6.9.3.
Applicable Standards
Construction StandardEN 50288-7
Intrinsic SafetyIEC 60079-14
ConductorIEC 60228 class 2
Behavior in case of fireIEC 60332-1-2, IEC 60332-3-24 (Cat. C)
Oil ResistanceICEA S-73-532 / NEMA WC 57-2004
UV resistanceUL 1581 Section 1200
CPR RegulationEca
DIMENSIONAL TABLE
mm² formationdiameter [mm]Weight [kg/Km]Cor
02X2X0.510.7120Black
04X2X0.512.1160Black
06X2X0.514.1210Black
08X2X0.514.9225Black
12X2X0.517.4340Black
16X2X0.519.5430Black
24X2X0.523580Black
02X2X0.7511.4140Black
04X2X0.7513190Black
06X2X0.7515.2260Black
08X2X0.7516.1310Black
12X2X0.7518.8410Black
16X2X0.7521.1530Black
24X2X0.7525.5760Black
02X2X110.4118Black
02X2X1.312.6135Black
04X2X1.314.4220Black
06X2X1.317301Black
08X2X1.318389Black
12X2X1.321.3580Black
16X2X1.324.3719Black
24X2X1.3291090Black
02X2X0.510.7120Blue
04X2X0.512.1160Blue
06X2X0.514.1210Blue
08X2X0.514.9225Blue
12X2X0.517.4340Blue
16X2X0.519.5430Blue
24X2X0.523580Blue
02X2X0.7511.4140Blue
04X2X0.7513190Blue
06X2X0.7515.2260Blue
08X2X0.7516.1310Blue
12X2X0.7518.8410Blue
16X2X0.7521.1530Blue
24X2X0.7525.5760Blue
02X2X1.312.6135Blue
04X2X1.314.4220Blue
06X2X1.317301Blue
08X2X1.318389Blue
12X2X1.321.3580Blue
16X2X1.324.3719Blue
24X2X1.3291090Blue
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.