Medium Voltage Power Cable; Max. 500,00 mm²; 6 to 35 kV; 1 conductor; XLPE / PVC; Flame retardant; +90°C
Medium Voltage Cable Innovnax® XLPE 3,6/6KV to 20/35KV 90°C – NBR 7287
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Maximum Thermal Performance: XLPE insulation that withstands 90°C, ensuring total stability and safety during operation.
- Durability and Safety: Manufactured in accordance with NBR 7287 standards, it has high impact resistance for maximum reliability.
- Unparalleled Versatility: Perfect for substations, industries, and businesses, adapting excellently to the needs of your project.
- Simplified Installation: Suitable for outdoor installations, in conduits, raceways and also in duct banks.
- Superior Energy Efficiency: Pure copper conductor and ST2 PVC sheath that guarantee maximum performance and protection.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | INNOVCABLE |
| Product type | Medium voltage power cable with XLPE (cross-linked polyethylene) insulation. |
| Córdoba | INNOVNAX XLPE 90°C |
| Electrical Parameters | |
| Nominal Voltage | From 3,6/6 kV to 20/35 kV. |
| Product Design | |
| Conductor Material | Bare electrolytic copper wires, soft temper. |
| Driver Design | Class 2 or 5 string set. |
| Conductor Shielding | Thermoset Semiconductor Compound (optional for the 3.6/6 kV class). |
| Base Material for Vein Isolation | XLPE 90°C (thermoset compound based on cross-linked polyethylene). |
| Insulation Shielding | Thermoset Semiconductor Compound (optional for the 3.6/6 kV class). |
| Metal Shielding | Bare copper wires with a cross-section of 6mm², with helical application (other cross-sections available upon request). |
| Separator | Tape made of non-hygroscopic material. |
| Base Material for the External Covering | Thermoplastic compound based on polyvinyl chloride (PVC/ST2). |
| Abbreviation for Roofing Material | PVC/ST2 |
| Cover Color | Black (other colors available upon request). |
| Road Identification | Driver 1: Insulation in natural color. 3 drivers: colored ribbons (white, blue and red), insulation in the colors (white, blue and red) or numbered black veins. |
| Product characteristics | |
| Application Area | Power supply and distribution in substations, industrial and commercial facilities, and building entrances. |
| Installation Mode | It can be installed outdoors, in conduits, raceways or duct banks. |
| Flexibility | Good flexibility. |
| Mechanical Resistance | Good impact resistance. |
| Minimum Radius of Curvature | 12 times the outer diameter of the cable (12xD). |
| Maximum temperature in the driver | Permanent regime: 90°C Overload regime: 130°C Short-circuit regime: 250°C |
| UV resistant | Yes, suitable for outdoor installation. |
| Halogen-free | No (PVC covering). |
| Applicable Standards | |
| NBR 7287 | Power cables with extruded cross-linked polyethylene (XLPE) insulation for voltages from 1 kV to 35 kV. |
| NBR NM 280 | Insulated cable conductors. |
| NBR 6251 | Power cables with extruded insulation. |
| NBR 14039 | Medium voltage electrical installations from 1,0 kV to 36,2 kV. |
| NBR 11137 | Not specified in the document. |
| Driver Type | Nominal Section (mm²) | Conductor Nominal Diameter (mm) | Insulation Nominal Thickness (mm) | Maximum External Diameter (mm) | Nominal Net Weight (kg/km) |
| 3 Conductors - 6/10 kV | 16 | 4,7 | 3,4 | 36,0 | 1.765 |
| 3 Conductors - 6/10 kV | 25 | 5,9 | 3,4 | 38,8 | 2.190 |
| 3 Conductors - 6/10 kV | 35 | 7,0 | 3,4 | 41,3 | 2.634 |
| 3 Conductors - 6/10 kV | 50 | 8,1 | 3,4 | 44,0 | 3.129 |
| 3 Conductors - 6/10 kV | 70 | 9,6 | 3,4 | 47,3 | 3.874 |
| 1 Conductor - 3,6/6 kV | 16 | 4,7 | 2,5 | 16,1 | 407 |
| 1 Conductor - 3,6/6 kV | 25 | 5,9 | 2,5 | 17,3 | 515 |
| 1 Conductor - 3,6/6 kV | 35 | 7,0 | 2,5 | 18,4 | 630 |
| 1 Conductor - 3,6/6 kV | 50 | 8,1 | 2,5 | 19,6 | 757 |
| 1 Conductor - 3,6/6 kV | 70 | 9,6 | 2,5 | 21,0 | 956 |
| 1 Conductor - 3,6/6 kV | 95 | 11,3 | 2,5 | 22,9 | 1.229 |
| 1 Conductor - 3,6/6 kV | 120 | 12,8 | 2,5 | 24,4 | 1.463 |
| 1 Conductor - 3,6/6 kV | 150 | 14,2 | 2,5 | 26,4 | 1.788 |
| 1 Conductor - 3,6/6 kV | 185 | 15,8 | 2,5 | 28,0 | 2.102 |
| 1 Conductor - 3,6/6 kV | 240 | 18,2 | 2,6 | 30,8 | 2.698 |
| 1 Conductor - 3,6/6 kV | 300 | 20,7 | 2,8 | 34,1 | 3.356 |
| 1 Conductor - 3,6/6 kV | 400 | 23,5 | 3,0 | 37,9 | 4.276 |
| 1 Conductor - 3,6/6 kV | 500 | 26,5 | 3,2 | 41,5 | 5.280 |
| 3 Conductors - 8,7/15 kV | 25 | 5,9 | 4,5 | 44,0 | 2.584 |
| 3 Conductors - 8,7/15 kV | 35 | 7,0 | 4,5 | 46,4 | 3.052 |
| 3 Conductors - 8,7/15 kV | 50 | 8,1 | 4,5 | 49,1 | 3.572 |
| 3 Conductors - 8,7/15 kV | 70 | 9,6 | 4,5 | 52,5 | 4.349 |
| 1 Conductor - 12/20 kV | 35 | 7,0 | 5,5 | 24,4 | 828 |
| 1 Conductor - 12/20 kV | 50 | 8,1 | 5,5 | 25,8 | 978 |
| 1 Conductor - 12/20 kV | 70 | 9,6 | 5,5 | 27,2 | 1.190 |
| 1 Conductor - 12/20 kV | 95 | 11,3 | 5,5 | 29,1 | 1.482 |
| 1 Conductor - 12/20 kV | 120 | 12,8 | 5,5 | 30,6 | 1.729 |
| 1 Conductor - 12/20 kV | 150 | 14,2 | 5,5 | 32,8 | 2.087 |
| 1 Conductor - 12/20 kV | 185 | 15,8 | 5,5 | 34,4 | 2.416 |
| 1 Conductor - 12/20 kV | 240 | 18,2 | 5,5 | 37,3 | 3.047 |
| 1 Conductor - 12/20 kV | 300 | 20,7 | 5,5 | 39,7 | 3.679 |
| 1 Conductor - 12/20 kV | 400 | 23,5 | 5,5 | 43,8 | 4.657 |
| 1 Conductor - 12/20 kV | 500 | 26,5 | 5,5 | 46,9 | 5.664 |
| 3 Conductors - 3,6/6 kV | 16 | 4,7 | 2,5 | 32,1 | 1.527 |
| 3 Conductors - 3,6/6 kV | 25 | 5,9 | 2,5 | 34,7 | 1.915 |
| 3 Conductors - 3,6/6 kV | 35 | 7,0 | 2,5 | 37,2 | 2.341 |
| 3 Conductors - 3,6/6 kV | 50 | 8,1 | 2,5 | 39,9 | 2.815 |
| 3 Conductors - 3,6/6 kV | 70 | 9,6 | 2,5 | 43,3 | 3.535 |
| 1 Conductor - 8,7/15 kV | 25 | 5,9 | 4,5 | 18,3 | 542 |
| 1 Conductor - 8,7/15 kV | 35 | 7,0 | 4,5 | 19,4 | 659 |
| 1 Conductor - 8,7/15 kV | 50 | 8,1 | 4,5 | 20,6 | 788 |
| 1 Conductor - 8,7/15 kV | 70 | 9,6 | 4,5 | 22,2 | 1.000 |
| 1 Conductor - 8,7/15 kV | 95 | 11,3 | 4,5 | 23,9 | 1.265 |
| 1 Conductor - 8,7/15 kV | 120 | 12,8 | 4,5 | 25,6 | 1.513 |
| 1 Conductor - 8,7/15 kV | 150 | 14,2 | 4,5 | 27,4 | 1.830 |
| 1 Conductor - 8,7/15 kV | 185 | 15,8 | 4,5 | 29,2 | 2.160 |
| 3 Conductors - 12/20 kV | 35 | 7,0 | 5,5 | 51,0 | 3.454 |
| 3 Conductors - 12/20 kV | 50 | 8,1 | 5,5 | 53,7 | 3.997 |
| 3 Conductors - 12/20 kV | 70 | 9,6 | 5,5 | 57,0 | 4.802 |
| 1 Conductor - 15/25 kV | 50 | 8,1 | 6,8 | 28,6 | 1.099 |
| 1 Conductor - 15/25 kV | 70 | 9,6 | 6,8 | 30,0 | 1.318 |
| 1 Conductor - 15/25 kV | 95 | 11,3 | 6,8 | 32,1 | 1.630 |
| 1 Conductor - 15/25 kV | 120 | 12,8 | 6,8 | 33,8 | 1.901 |
| 1 Conductor - 15/25 kV | 150 | 14,2 | 6,8 | 35,7 | 2.240 |
| 1 Conductor - 15/25 kV | 185 | 15,8 | 6,8 | 37,4 | 2.594 |
| 1 Conductor - 15/25 kV | 240 | 18,2 | 6,8 | 39,9 | 3.200 |
| 1 Conductor - 15/25 kV | 300 | 20,7 | 6,8 | 43,1 | 3.912 |
| 1 Conductor - 15/25 kV | 400 | 23,5 | 6,8 | 46,6 | 4.858 |
| 1 Conductor - 15/25 kV | 500 | 26,5 | 6,8 | 49,8 | 5.880 |
| 1 Conductor - 20/35 kV | 50 | 8,1 | 8,8 | 33,2 | 1.330 |
| 1 Conductor - 20/35 kV | 70 | 9,6 | 8,8 | 34,7 | 1.560 |
| 1 Conductor - 20/35 kV | 95 | 11,3 | 8,8 | 36,3 | 1.856 |
| 1 Conductor - 20/35 kV | 120 | 12,8 | 8,8 | 38,0 | 2.138 |
| 1 Conductor - 20/35 kV | 150 | 14,2 | 8,8 | 39,9 | 2.489 |
| 1 Conductor - 20/35 kV | 185 | 15,8 | 8,8 | 41,4 | 2.835 |
| 1 Conductor - 20/35 kV | 240 | 18,2 | 8,8 | 44,7 | 3.528 |
| 1 Conductor - 20/35 kV | 300 | 20,7 | 8,8 | 47,3 | 4.211 |
| 1 Conductor - 20/35 kV | 400 | 23,5 | 8,8 | 50,8 | 5.180 |
| 1 Conductor - 20/35 kV | 500 | 26,5 | 8,8 | 54,0 | 6.223 |
| 1 Conductor - 6/10 kV | 16 | 4,7 | 3,4 | 17,9 | 445 |
| 1 Conductor - 6/10 kV | 25 | 5,9 | 3,4 | 19,1 | 566 |
| 1 Conductor - 6/10 kV | 35 | 7,0 | 3,4 | 20,2 | 684 |
| 1 Conductor - 6/10 kV | 50 | 8,1 | 3,4 | 21,4 | 814 |
| 1 Conductor - 6/10 kV | 70 | 9,6 | 3,4 | 22,8 | 1.017 |
| 1 Conductor - 6/10 kV | 95 | 11,3 | 3,4 | 24,7 | 1.295 |
| 1 Conductor - 6/10 kV | 120 | 12,8 | 3,4 | 26,2 | 1.533 |
| 1 Conductor - 6/10 kV | 150 | 14,2 | 3,4 | 28,2 | 1.864 |
| 1 Conductor - 6/10 kV | 185 | 15,8 | 3,4 | 29,8 | 2.182 |
| 1 Conductor - 6/10 kV | 240 | 18,2 | 3,4 | 32,6 | 2.788 |
| 1 Conductor - 6/10 kV | 300 | 20,7 | 3,4 | 35,3 | 3.420 |
| 1 Conductor - 6/10 kV | 400 | 23,5 | 3,4 | 38,7 | 4.323 |
| 1 Conductor - 6/10 kV | 500 | 26,5 | 3,4 | 42,5 | 5.355 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.