Power and Control Cable, Mobile Use; 0,6/1 kV; 3 to 30 conductors; max. 1,00 mm², Numbered Cores; LSZH, INNOVLON™ / PUR-AC, Flame and Oil Resistant; -30°C/+70°C
Cable for Elevator Control / Command / Power Shielded Innovlift® K2YSTFU11Y, K2YSTFU11Y, K9YSTFU11Y, K9YSTCU11Y
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Unparalleled Security: Halogen-free and flame-retardant material that does not generate toxic gases in case of fire.
- Noise-Free Transmission: Superior shielding with EMC technology ensures clean signals free from electromagnetic interference.
- Robust Construction: PUR coating resistant to mechanical stress, moisture and extreme temperature variations.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | INNOVLIFT® |
| Product type | Halogen-free elevator control cable with medium-stress bearing element. Suitable for dry and humid environments. |
| Model Names | K9YSTFU11Y, K9YSTCU11Y, K12YSTCU11Y, K2YSTFU11Y |
| Electrical Parameters | |
| Nominal Voltage | For cross-sections >0,5 mm² = 300 V; for cross-sections >1,0 mm² = Uo/U 300/500 V |
| Current Capacity | According to DIN VDE, see technical guide. |
| Product Design | |
| Conductor Material | Bare copper wires |
| Driver Class | According to DIN VDE 0295 class 5/6 / IEC 60228 class 5/6 |
| Base Material for Vein Isolation | Special thermoplastic compound |
| Road Identification | According to VDE 0293, black wires with white numbering, with protective conductor (GN/YE). Version 3x(2x0,5) according to DIN 47100. |
| Type of Twist | Twisted paths in pairs, and twisted pairs in layers. |
| Shielded | - K9YSTCU11Y / K12YSTCU11Y: General shielding with tinned copper braid, coverage approx. 85% - K2YSTFU11Y / K9YSTFU11Y: Pairs of shielded elements with tinned copper braid, coverage approx. 75% |
| Supporting Element | Textile support element (Model K2YSTFU11Y 20G1+3X(2X0,5)C has a steel support element) |
| Base Material for the External Covering | PUR (Polyurethane) |
| Cover Color | Black, RAL 9005 |
| Product characteristics | |
| Application Area | Control cable for elevators in dry and humid environments. |
| Minimum Radius of Curvature | 15 x cable diameter (for fixed and mobile installation) |
| Speed | Maximum of 1.6 m/s |
| Suspension Height | Consult the manufacturer's table. |
| Temperature, fixed installation | -30°C to +70°C |
| Temperature, constant movement | -30°C to +70°C |
| Flame retardant | Self-extinguishing and flame retardant according to IEC 60332-2-2 |
| Halogen-free | Yes, according to IEC 60754-1. |
| Chemical resistant | Free from silicone and substances that damage the paint (during production). |
| Special features | Electromagnetic Compatibility (EMC) |
| Applicable Standards | |
| DIN VDE 0295 cl. 6 / IEC 60228 cl. 6 | Regarding the driver's class |
| IEC 60754-1 | Regarding the absence of halogen |
| IEC 60332 2 2 | Regarding behavior during flames |
| DIN VDE 0282 | Similar construction |
| RoHS | Compliant with the RoHS directive. |
| Low Voltage Directive | In accordance with directive 2014/35/EU |
| Variant | Dimension (nx mm²) | External Diameter (mm) | Copper Index (kg/km) | Weight (kg/km) | Cover Color | Suspension Height (m) |
| K2YSTFU11Y | 20 G 1 + 3 X (2 X 0,5)C | 22 | 260 | 630 | black | 50 |
| K2YSTFU11Y | 30 G 1 + 3 X (2 X 0,5)C | 26,1 | 369 | 905 | black | 50 |
| K9YSTFU11Y | 30 G 1 + 3 X (2 X 0,5)C | 22 | 369 | 670 | black | 50 |
| K12YSTCU11Y / K9YSTCU11Y | 3 x (2 x 0,75) | 12,1 | 81 | 175 | black | 30 |
| K12YSTCU11Y / K9YSTCU11Y | 6 x (2 x 0,75) | 15,8 | 182 | 370 | black | 50 |
| K2YSTFU11Y | 24 G 1 + 3 X (2 X 0,5)C | 23,4 | 289 | 755 | black | - |
| K2YSTFU11Y | 18 G 1 + 3 X (2 X 0,5)C | 23,4 | 239 | 585 | black | - |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.




