Power and Control Cable, Mobile Use; 0,6/1 kV; 1 to 12 conductors; max. 70,0 mm², Numbered Cores; LSZH, CECO™ / CECO™ / CEAC™, Flame and Oil Resistant; -50°C/+90°C
Cable for Mobile Use Control / Command / Power Festoon Winders Festooncable® (N) GRDGOU
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Superior Resistance to Movement: Designed to withstand intense mechanical stress and frequent flexing in mobile equipment and treadmills.
- Performance in Extreme Temperatures: Reliable operation in temperatures from -50°C (fixed installation) to +90°C (on the conductor).
- Security and Trust Guaranteed: Made from a special rubber compound that is self-extinguishing and flame-retardant.
- Versatility in Any Environment: Ideal for applications in dry, damp, and wet environments, as well as for outdoor use.
- Designed for High Speed: It supports travel speeds of up to 240 m/min in festoon systems.
- Conductor: Bare electrolytic copper, extra flexible, class 5. Can be manufactured in tin-plated copper upon request.
- Insulation: Special Elastomeric Compound (CECO®); enhanced mechanical and electrical characteristics.
- Conductor identification: Excellent identification through black insulation with sequentially printed numbers for power and control cables, and green grounding conductor.
- Arrangement of conductors: Grouped in a maximum of 3 layers.
- Inner sheath: Special Elastomeric Compound (CECO®). Color: black.
- Outer sheath: Special Elastomeric Compound (CEAC®). Color: black.
- Marking: FESTOONCABLE®
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | FESTOONCABLE (N) GRDGÖU |
| Product type | Low voltage power and control cable for festoon systems, cable carriers and moving parts of equipment under high mechanical stress. |
| Type Designation | (N)GRDGOU / FESTOONCABLE |
| Electrical Parameters | |
| Nominal Voltage | Uo/U: 0,6/1 kV |
| Maximum Operating Voltage (AC) | 0,7 / 1,2 kV |
| Maximum Operating Voltage (DC) | 0,9 / 1,8 kV |
| Test Voltage | 2,5 kV / 3,5 kV / 4 kV |
| Product Design | |
| Conductor Material | Flexible bare electrolytic copper wires, can be manufactured in tin-plated copper upon request. |
| Driver Design | Finely braided copper, class 5, according to DIN VDE 0295 / IEC 60228. |
| Current Capacity | According to DIN VDE 0298-4. |
| Road Isolation | CECO™ special elastomeric compound |
| Road Identification | Light-colored insulation with black printed numbers; includes green protective (ground) conductor. |
| Road color code | According to VDE 0293 / VDE 0293-308. |
| Type of Twist | Twisted, layered paths. |
| Intermediate Cover | CECO™ special elastomeric compound |
| Outer Cover | CEAC™ special elastomeric compound |
| Cover Color | Black. |
| shielding | No |
| Cable Format | Round. |
| Product characteristics | |
| Application Area | Festoon systems, cranes, conveyors and handling equipment. Suitable for dry, humid, wet environments and for outdoor use. |
| For continuous bending | Yes, designed for frequent bending under high mechanical stress. |
| Torsional Strength | Yes, it allows for a torsional stress of ±25°/m and ±90°/m. |
| Traction Load | Maximum of 15 N/mm² in the conductor. |
| Displacement Speed | Up to 240 m/min in festoon systems. |
| Minimum Radius of Curvature (movable) | According to DIN VDE 0298-3 or 5 x outside diameter. |
| Minimum Radius of Curvature (fixed) | According to DIN VDE 0298-3 or 4 x outside diameter. |
| Temperature, fixed installation | It varies between -50°C and +90°C. |
| Temperature, constant movement | It varies between -35°C and +90°C. |
| Maximum temperature in the driver | +90°C. |
| Short-Circuit Temperature | Maximum temperature of 250°C. |
| Flame retardant | Yes, self-extinguishing and flame retardant according to IEC 60332-1-2 and/or IEC 60332-2-1. |
| Oil Resistant | Yes, in accordance with DIN EN 60811-404 and IEC 60811-2-1. |
| UV resistant | Yes, it is resistant to UV rays, ozone, and humidity. |
| Cold Resistant | Yes. |
| Tear Resistant | Yes. |
| Silicone-free | Yes (during the production process). |
| Standards and Compliance | |
| Construction Standard | Based on DIN VDE 0250-814. |
| Driver's Rules | DIN VDE 0295 Class 5 / IEC 60228 Class 5. |
| Application Standards | DIN VDE 0298-3, DIN VDE 0298-4. |
| Directives | Compliance with the Low Voltage Directive (2014/35/EU), RoHS and REACH. |
| Dimensional nxmm² | Outer diameter Ø mm | Weight kg/km |
| 1X35 | 13,9 | 430 |
| 1X50 | 16,6 | 625 |
| 1X70 | 18,5 | 835 |
| 1X95 | 20,9 | 1070 |
| 1X120 | 22,8 | 1340 |
| 1X150 | 24,9 | 1650 |
| 1X185 | 27,8 | 2010 |
| 12G1,5 | 18,2 | 440 |
| 18G1,5 | 20,7 | 615 |
| 24G1,5 | 24,1 | 805 |
| 30G1,5 | 25,3 | 930 |
| 36G1,5 | 27,6 | 1090 |
| 12G2,5 | 19,9 | 580 |
| 18G2,5 | 23,5 | 865 |
| 24G2,5 | 27,0 | 1110 |
| 30G2,5 | 29,4 | 1330 |
| 36G2,5 | 31,4 | 1550 |
| 4G4 | 15,5 | 350 |
| 5G4 | 17,7 | 450 |
| 4G6 | 17,9 | 475 |
| 5G6 | 19,5 | 575 |
| 4G10 | 20,2 | 680 |
| 5G10 | 22,8 | 865 |
| 4G16 | 24,9 | 1070 |
| 5G16 | 27,6 | 1300 |
| 4G25 | 29,9 | 1600 |
| 5G25 | 32,5 | 1940 |
| 4G35 | 33,1 | 2090 |
| 4G50 | 38,7 | 2970 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.