PROFIBUS DP INNOVTRONIC® PB 105: Thermal Resistance and Industrial ReliabilityEnsure the integrity of your PROFIBUS DP network even in the harshest environments. The PROFIBUS DP INNOVTRONIC® PB 105 is the ultimate solution for fixed installations in high-temperature areas, supporting up to 105°C without compromising data transmission. Its robust construction offers superior security and performance where conventional cables fail.
  • High Temperature Support: Specifically designed for continuous operation in industrial buildings with temperatures up to 105°C.
  • Efficient Double Shielding: Combination of aluminum foil and tinned copper mesh for maximum protection against electromagnetic interference.
  • Ideal for Painting Areas: PWIS-free certification (VDMA 24364), guaranteeing that the cable does not contaminate sensitive painting processes.
  • Proven Safety: Violet PVC coating, resistant to oils and flame retardant according to IEC 60332-1-2 standard.
  • Stable Performance: Nominal impedance of 150 Ω optimized for PROFIBUS DP systems in fixed installations.
Product Design
  • Application: Fixed installation in environments with temperatures up to +105°C.
  • Conductor material: Bare copper (7 wires)
  • Core insulation: Polypropylene (PP)
  • Overall shielding: Aluminum laminated plastic tape and tinned copper braid.
  • Outer cover material: Polyvinyl chloride (PVC)
  • Outer cover color: Violet (RAL 4001)
  • Nominal characteristic impedance: 150 Ω
  • Maximum operating voltage: 100 V (not for power transmission)
  • Temperature range (fixed installation): -30°C to +105°C
  • Flame retardant: As per IEC 60332-1-2
  • Oil resistance: Yes
  • Free of PWIS (substances that interfere with paint): Yes
  • Fast Connect (FC) system: No
Details

Benefits

  • High thermal resistance: Specifically designed to operate in environments up to +105°C.
  • Paint compatibility: Free from PWIS (LABS) substances, ideal for automotive paint lines.
  • Electromagnetic protection: Double shielding (foil + mesh) ensures interference-free data transmission.
  • Oil resistance: PVC coating suitable for industrial environments with the presence of lubricants.
  • Fire safety: Flame retardant material in accordance with IEC 60332-1-2.
  • Wide operating range: It withstands extreme temperatures from -30°C to +105°C in fixed installations.
  • PROFIBUS reliability: Characteristic impedance of 150 Ω for stable DP networks.
  • Static durability: Robust construction optimized for long-term fixed installations.
  • Quality Approved: Compliance with technical standards for specific international markets.
  • Ease of handling: Round and compact design for efficient installation in gutters and ducts.

Applications

  • High temperature areas: Connections near furnaces, ovens, and industrial heat zones.
  • Painting lines: The automotive and home appliance industries are critically affected by the absence of PWIS (Product Width Information System).
  • Factory automation: PROFIBUS DP network cabling in stationary machines.
  • Plastic injection molding: Monitoring and control near heating guns and molds.
  • Steel and metallurgy: Data transmission in warehouses with high ambient temperatures.
  • Ceramic industry: Automation of processes in drying and burning areas.
  • Electrical panels: Internal cabling in control cabinets with high thermal density.
  • Glass industry: Process control in hot manufacturing and treatment zones.
  • Exhaust systems: Connecting sensors to ducts and motors in industrial ventilation systems.
  • Fixed infrastructure: Fieldbus networks where there is no continuous movement or bending.
Technical Data
General information
BrandInnovcable®
Product typeBus cable
CórdobaPROFIBUS DP INNOVTRONIC® PB 105
Valid Fieldbus SystemPROFIBUS-DP
Weight72kg/km
Copper Index30.1kg/km
Electrical Parameters
Maximum Operating Voltage100 V (not for power transmission)
Test Voltage (conductor/conductor)1.5 kV
Test Voltage (core/shield)1.5 kV
Nominal Surge Impedance150 Ω
Product Design
Conductor Count/Size1x2x0,64
Nominal Conductor Diameter0.64 mm
Number of wires7
Conductor MaterialBare copper
Driver Design7 wires (7-wire)
Includes protective conductor (ground).No
Number of pairs1
String TypeTwisted-pair
ShieldedYes
General Armor TypeAluminum laminated plastic sheet + Tinned copper braid
Wrapping over the ArmorFleece wrapping
Nominal Vein Diameter2.55 mm
Nominal Outside Diameter8 mm
Cable FormatRound
Base Material for Vein IsolationPolypropylene (PP)
Base Material for the External CoveringPolyvinyl chloride (PVC)
Color of the Exterior CoverViolet (RAL 4001)
Vein IdentificationColors
Product characteristics
Application AreaFixed installation
For continuous bendingNo
For torsional loadNo
Minimum Bending Radius (Fixed Installation)45 mm
Minimum Radius of Curvature (Occasional Bending)65 mm
Maximum Conductor Temperature (Fixed Installation)-30 ° C to 105 ° C
Flame retardantYes (IEC 60332-1-2)
UV resistantNo
Halogen-freeNo
Oil ResistantYes
Free from PWIS (substances that damage paint).Yes (VDMA 24364-B2-L)
Fast Connect (FC) cableNo
Dimensional Table
Conductors / ConstructionExternal Diameter (mm)Copper Weight (kg/km)Total Weight (kg/km)
1x2x0.648.030.172

 

RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.