Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; PVC; violet

INNOVTRONIC® PB TRAY PROFIBUS DP CABLE

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Agility and Economy with PROFIBUS DP INNOVTRONIC® PB TRAYRevolutionize your PROFIBUS DP network by eliminating unnecessary costs. With PLTC-ER approval, this cable allows for open installation between trays and machines, eliminating the need for extra protective conduits. A robust solution that combines quick assembly with maximum regulatory safety for your data transmission.
  • PLTC-ER compliant: Allows for exposed wiring (Open Wiring) as per NEC standards, drastically reducing time and materials.
  • External Durability: Violet coating resistant to UV rays and flame retardant (UL FT4).
  • Double Shielding: Aluminum tape and copper mesh ensure complete immunity against electromagnetic interference.
  • Multiprotocolo: Superior performance in PROFIBUS-DP, FMS and FIP networks, whether fixed or with occasional movement.
  • Technical Reliability: 150 Ω impedance ensures signal integrity over long distances.
Product Design
  • Conductor count/size: 1x2x0,64
  • Nominal conductor diameter: 0.64 mm
  • Conductor material: Bare copper (1 wire)
  • Core insulation base material: Polyolefin (PO)
  • Inner cover base material: Polyvinyl chloride (PVC)
  • Overall shielding: Aluminum laminated plastic tape and tinned copper braid.
  • Wrapping above the shielding: Plastic film
  • Outer cover base material: Polyvinyl chloride (PVC)
  • Cable sheath color: Violet
  • Nominal outer diameter: 8.4 mm
  • Nominal surge impedance: 150 Ω
  • Maximum conductor temperature (fixed installation): -40°C to 80°C
  • Conductor/conductor test voltage: 2 kV
  • UV resistance: Yes (UL sunlight resistant)
  • Flame retardancy: Yes (UL FT4)
Details

Benefits

  • Simplified installation: PLTC-ER certification allows for open wiring without conduits.
  • Cost Savings: It eliminates the need for additional protection between the chute and the industrial machine.
  • UV resistance: For greater durability under sunlight.
  • Fire safety: Meets rigorous UL FT4 flame tests.
  • Effective EMC protection: Double shielding (tape and mesh) against electromagnetic interference.
  • Versatility of use: Designed for fixed installation and occasional movement.
  • Global compatibility: International compliance.
  • PWIS free: It does not interfere with the wettability of the paint in painting processes.
  • Wide temperature range: Operates safely from -40°C to +80°C (fixed installation).
  • Multiple protocols: Suitable for PROFIBUS-DP, FMS and FIP.

Applications

  • Industrial automation: PROFIBUS DP communication networks on the factory floor.
  • Cable trays: Direct installation in gutters according to NEC standards.
  • Machine connection: Exposed connection between infrastructure and equipment.
  • SIMATIC® Systems: Seamless integration with SIEMENS NET hardware.
  • Factory instrumentation: Support for the FIP (Factory Instrumentation Protocol).
  • Industrial plants: Projects that require "Exposed Run" (ER) approval.
  • Mixed environments: Locations that require UV and mechanical resistance.
  • Sensors and actuators: Secure data transmission at the field level.
  • Process engineering: Control wiring in production areas.
  • Retrofit and expansion: Ease of installation in existing structures.
Technical Data

 

General information
BrandInnovcable®
Product's namePROFIBUS DP INNOVTRONIC® PB TRAY 1x2x0,64
Product typeNetwork cable (Bus cable) - PROFIBUS DP
Weight82kg/km
Copper Index26kg/km
Valid Fieldbus SystemPROFIBUS-DP
Electrical Parameters
Maximum Operating Voltage250 V (not for power transmission)
Test Voltage (Conductor/Conductor)2 kV
Test Voltage (Vein/Shield)2 kV
Nominal Surge Impedance150 Ω
Product Design
Conductor Count/Size1x2x0,64
Nominal Conductor Diameter0,64 mm
Number of wires1 (Solid)
Conductor MaterialBare copper
Includes protective conductor.No
Number of veins2
Number of pairs1
String typeTwisted-pair
ShieldedYes
General type of armorAluminum laminated plastic sheet + Tinned copper braid
Wrapping over the shieldingPlastic film
Nominal Outside Diameter8,4 mm
Cable FormatRound
Base Material for Vein IsolationPolyolefin (PO)
Inner Cover Base MaterialPolyvinyl chloride (PVC)
Base Material for the External CoveringPolyvinyl chloride (PVC)
Cover ColorVioleta
Road IdentificationColors
Product characteristics
Application AreaFixed installation; Applications with occasional movement.
Installation TypeCable Tray (PLTC-ER)
For continuous bendingNo
For torsional loadNo
CoilableNo
Minimum Radius of Curvature (Stationary)8 x outer diameter
Minimum Bending Radius (Fixed Installation in mm)67,2 mm
Maximum temperature in the conductor (Fixed installation)-40°C to 80°C
Maximum temperature in the driver (Occasional movement)-10°C to 70°C
Flame retardantYes (UL FT4)
UV resistantYes (UL sunlight resistant)
Halogen-freeNo
Oil resistantNo
Free from PWIS (Substances harmful to paint)Yes (according to VDMA 24364-B2-L)
Fast Connect (FC) cableNo
Dimensional Table
Conductors / ConstructionExternal Diameter (mm)Copper Weight (kg/km)Total Weight (kg/km)
1x2x0.648.530.182

 

RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.