Power cable; 1,8/3 kV AC; 1 conductor; 300,00 mm²; LSZH, INNOVPO-36 / INNOVPO-44; Flame resistance; 120°C

Photovoltaic Solar Cable ECO180H LSZH + UV 1,8/3KV AC/AC

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Photovoltaic Solar Cable for Maximum Performance and SafetyDeveloped for solar power installations that demand maximum reliability and durability in harsh environments. This cable ensures the safest and most efficient connection between panels, string boxes, and inverters, protecting your investment and optimizing the energy generation of your photovoltaic system for over 25 years.
  • Superior Protection and Security: Special non-halogenated compound with low smoke emission and flame retardant properties.
  • Maximum Power Generation: Tinned copper conductors that prevent oxidation and ensure maximum performance.
  • Extreme Resistance to Weathering: Protection against UV rays, ozone, humidity and temperature variations (-40°C to 120°C).
  • Installation Flexibility: Extra flexible for easy handling and installation in any type of project.
  • Quality and Guaranteed Lifespan: Manufactured in accordance with NBR 16612 standards, ensuring the highest quality for your system.
PRODUCT DESIGN
  • Conductor material: tinned copper wires
  • Driver class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
  • Insulation: HEPR rubber compound 125°C
  • Cover: special thermoset rubber compound, UV resistant, 125°C
  • Insulation color: natural
  • Cover color: black, red, blue, or violet
DETAILS

Benefits

  • Superior Resistance to UV Rays: Special coating that prevents degradation from continuous sun exposure.
  • Long Useful Life (Over 25 years): Designed to match the durability of solar panels.
  • Enhanced Fire Safety: Non-halogenated compound with low emission of smoke and toxic gases.
  • Maximum Climate Protection: Immune to the effects of inclement weather such as rain, ozone, and temperature variations.
  • Double Safety Insulation: Enhanced protection against electrical faults and shock risks.
  • Installation Flexibility: Class 5 conductor that facilitates handling and passage through conduits.
  • Reliable Electrical Performance: Ensures minimal energy loss between the modules and the inverter.
  • Wide Temperature Range: Safe and stable operation in temperatures from -40°C to +90°C.
  • Compliance with ABNT Standard: Manufactured in accordance with the strict standards of NBR 16612.
  • Reducing Maintenance Costs: High durability that minimizes the need for replacements and repairs.

Applications

  • Residential Photovoltaic Systems: Secure connection of solar panels to roofs and slabs.
  • Commercial and Industrial Facilities: Connecting photovoltaic arrays in warehouses and factories.
  • Large Solar Power Plants (Solar Farms): Interconnection of rows of panels (strings) on the ground.
  • Distributed Generation Projects: Essential for on-grid systems connected to the utility grid.
  • Isolated Systems (Off-Grid): Powering battery banks in remote or autonomous locations.
  • Connection between the circuit board, string box, and inverter: Used throughout the direct current path of the system.
  • Installations on Floating Structures: High moisture resistance for plants built over water.
  • Solar Carports (Parking Lots): Connecting the modules to vehicle roof structures.
  • Solar Pumping Systems: Power supply for irrigation pumps and artesian wells.
  • Architectural Integration (BIPV): Application in facades and building structures with integrated panels.
TECHNICAL DATA
General information
BrandINNOVCABLE
Product typePhotovoltaic cable for photovoltaic systems in fixed and flexible applications.
CórdobaINNOVCABLE PHOTOVOLTAIC ECO180H LSZH + UV
Electrical Parameters
Rated voltage1,8/3 kV AC
Maximum Operating VoltageAC/AC: 2,1/3,6 kV; DC/DC: 2,7/5,4 kV
Test Voltage6,5 kV (5 min)
Insulation ResistanceMinimum 20 MΩ x km
Product Design
Conductor MaterialTinned copper wires
Driver ClassIn accordance with DIN VDE 0295 class 5 and IEC 60228 cl. 5
Vein IsolationSpecial cross-linked compound INNOVPO-36, heat resistant.
Outer CoverINNOVPO-44 special cross-linked compound, resistant to heat and UV.
Cover ColorBlack RAL 9005
Product characteristics
Application AreaPhotovoltaic systems for fixed and flexible applications, dry and humid locations, direct outdoor or directly buried installation, indoor and outdoor use in explosive and hazardous areas in industry and agriculture.
Operating Temperature+ 90 ° C
Maximum Temperature in the Conductor+120°C (max. 20.000 hours)
Short-Circuit Temperature+ 250 ° C
Temperature, Fixed Installation-40 ° C to + 90 ° C
Temperature, Flexible Installation-40 ° C to + 90 ° C
UV resistantYes
Ozone resistantYes
Acid and Base ResistanceYes
Abrasion ResistanceYes
Halogen-freeYes
Flame RetardantYes, for single and multi-cable systems.
Smoke EmissionLuminosity ≥ 70°C
CorrosivitypH ≥ 4,3; Conductivity ≤ 2,5 µS/mm
ToxicityITC Index = 3
LifetimeMinimum 25 years under direct solar radiation.
Direct BurialSuitable for direct burial in the ground.
Applicable Standards
DIN VDE 0295 CLASS 5IEC 60228 CLASS 5
DIN VDE 0250-606RAL 9005
DIN VDE 0298-4IEC 60332-1-2 (single cables)
IEC 60332-3-24 (multiple cables)EN-60754 2
EN 61034-2EN 50305
EN 50618
DIMENSIONAL TABLE

 

Dimensional and Physical Specifications
Conductor Cross-Section (mm²)Maximum Conductor Diameter (mm)External Diameter (mm)Maximum External Diameter (mm)Minimum Fixed Radius of Curvature (mm)Weight (Kg/km)
1 x 256,313,214,487380
1 x 357,414,315,593470
1 x 508,915,617,1103640
1 x 7010,617,119,1115820
1 x 9512,119,421,41291060
1 x 12014,221,523,51411320
1 x 15015,823,125,11511590
1 x 18517,425,127,11631910
1 x 24020,228,030,01802450
1 x 30022,931,034,02043030

 

RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.