Power cable; AC: 0,6/1 kV, DC: 0,9/1,5 kV; 1 conductor; 150,00 mm²; LSZH, INNOVLON / INNOVPUR; Flame resistance: 90°C
Innovlon® / Innovpur® LSZH UV Photovoltaic Solar Cable
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Fire Safety: Halogenated LSZH compound with low smoke and toxic gas emissions.
- Superior Weather Resistance: Protection against UV rays, ozone, humidity and extreme temperature variations (-40°C to 120°C).
- Maximum Electrical Performance: A voltage of 1,5kV (1500Vdc) that minimizes losses and optimizes the power generation of your system.
- Flexibility and Easy Installation: Extra flexible tinned copper conductor that facilitates handling and installation.
- Double Layer Insulation: High resistance against mechanical and chemical damage, as well as abrasion, ensuring greater durability.
- Conductor material: tinned copper wires
- Driver class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
- Insulation: halogen-free rubber compound
- Insulation color: white or red
- Cover: made of special halogen-free rubber compound, resistant to UV rays.
- Cover color: black or red
- Rated voltage Uo/U: 0,6/1 kV AC
- Maximum voltage: 1,8 kV DC (conductor-to-conductor, ungrounded circuit, unloaded circuit)
- Test voltage: 6,5 kV AC
- Insulation resistance: > 1 GOhm x km
- Operating temperature: -40°C to +90°C
- Maximum driver temperature: 120°C (for 20.000 hours)
- Minimum bending radius: 5 x cable diameter
- UV resistance: EN 50618
- Flame retardant: DIN EN 60332-1-2 and IEC 60332-1-2
- Halogen-free: DIN EN 50267-2-1 and IEC 60754-1
- Low smoke emission: DIN EN 61034 and IEC 61034
- Low gas toxicity: DIN EN 50267-2-2 and IEC 60754-2
- Expected lifespan: 25 years
- Reference standard: EN 50618 TUV 2 Pfg 1169/08.2007
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | INNOVCABLE |
| Product type | Cable for photovoltaic systems (INNOVLON / INNOVPUR-LSZH-UV) |
| Estimated useful life | Minimum 25 years under direct solar radiation, 20.000 ha, 120°C |
| Electrical Parameters | |
| Nominal Voltage (AC) | Uo/U: 0,6/1 kV |
| Nominal Voltage (DC) | 0,9 / 1,8 kV |
| Test Voltage | 4.000 V |
| Insulation Resistance | Minimum 20 MΩ x km |
| Product Design | |
| Conductor Material | Tinned or bare copper wires |
| Driver Design | Flexible, in accordance with DIN VDE 0295 class 5 and IEC 60228 class 5. |
| Base Material for Vein Isolation | INNOVLON Special Compound |
| Base Material for the External Covering | INNOVPUR Special Compound (LSZH) |
| Cover Color | Black (RAL 9005), other colors available upon request. |
| Road Identification | Insulation in white or red |
| Cable Format | Round |
| Product characteristics | |
| Application Area | Photovoltaic systems for fixed and flexible, traction-free applications. Can be used in dry, humid, and directly exposed weather conditions. |
| For continuous bending | Yes |
| Minimum Radius of Curvature (Fixed Use) | For diameter <= 12mm: 4 x outer diameter; For diameter > 12mm: 4 x outer diameter |
| Temperature, fixed installation | -40°C to +90°C |
| Temperature, constant movement | -40°C to +120°C |
| Maximum temperature in the driver | +120 °C (20.000h) |
| Short-Circuit Temperature | 250 ° C |
| Flame retardant | Yes, in accordance with IEC 60332-1 and DIN EN 60332-1 |
| Halogen-free | Yes (LSZH) |
| Low smoke emission | Yes |
| UV resistant | Yes, high resistance to the effects of solar radiation. |
| Oil resistant | Yes, resistant to oils and lubricants. |
| Chemical resistant | Resistant to acids, bases, ozone, and hydrolysis. |
| Weather resistance | Yes |
| Abrasion Resistance | Excellent |
| Additional Features | Eco-friendly, recyclable product. Manufactured free of harmful substances and silicone. |
| Applicable Standards | |
| DIN VDE 0295 cl. 5 | IEC 60228 cl. 5 |
| IEC 60332-1 | EN-60332 1 |
| EN 50618 | ABNT NBR 16612 |
| UL 2556 | DIN 0482-332-2 |
| Dimensional nx mm² | Outer diameter Ø mm | Weight kg/km |
| X 1 1,5 | 5,1 | 38 |
| X 1 2,5 | 5,7 | 50 |
| X 1 4 | 6,7 | 68 |
| X 1 6 | 7,6 | 91 |
| X 1 10 | 9,6 | 145 |
| X 1 16 | 11 | 204 |
| X 1 25 | 13,1 | 304 |
| X 1 35 | 14,1 | 401 |
| X 1 50 | 17,4 | 557 |
| X 1 120 | 24,3 | 1.233,00 |
| X 1 150 | 26,6 | 1.233,00 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.