DeepSea® Marine Instrumentation and Control Cable; NEK 606; S107 (S13) BU(i); 250V; Individual Shielding; Max. 2.50mm²; 1 to 32 pairs / trios / quads; MICA + XLPE – EPR / SHF2; Fire Resistant; +90°C

DeepSea® Marine Instrumentation Cable – Fire Resistant SHF2 S107 (S13) BU(i) 250 V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK 606 S107 Cable: Maximum Safety for Offshore InstrumentationDesigned for offshore environments, the S107 cable ensures the operation of critical instrumentation and control systems. Its fire-resistant and halogen-free construction offers maximum safety to protect lives and valuable assets.
  • Extreme Fire Resistance: Mica tape insulation keeps circuits active even under direct fire.
  • Pure and Reliable Signal: Individual shielding per pair blocks interference, ensuring accurate data communication.
  • Safe Construction: SHF2 zero halogen and low smoke coating, vital for safety in confined spaces.
  • Versatile Applications: Ideal for control, communication and alarms on platforms, ships and maritime units.
  • High Durability: Reliable performance in temperatures from -20°C to +90°C, ready for any challenge.
PRODUCT DESIGN
  • Conductors: Circular, stranded, corrugated, and tinned copper wire, conforming to IEC 60228 class 5 or class 2.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in Mica tape + EPR upon request.
  • Twist: Color-coded cores twisted together.
  • Individual Shielding: Each pair/trio/quad is shielded with copper-coated polyester tape in contact with a tinned copper drain wire and wrapped with polyester tape.
  • Outer Sheath: Halogen-free thermoset compound, SHF2.
  • Road Identification:
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Court colors: Black, Light Blue, Brown, and Gray.

  • Outer sheath: Gray (for standard instrumentation) or Blue (for Intrinsically Safe - IS circuits)
DETAILS

Benefits

  • Maximum Fire Safety: Fire-resistant construction that maintains the integrity of the circuits.
  • Halogen-free: It does not emit toxic or corrosive gases, protecting equipment and lives.
  • Low Smoke Emission: It ensures better visibility for emergency evacuation in case of fire.
  • Delayed Flame Propagation: It increases safety by limiting the spread of fire within the facility.
  • Reliable Signal Transmission: Effective individual shielding against electromagnetic interference.
  • Robust Construction: Mica tape and XLPE insulation with SHF2 outer covering for increased durability.
  • Wide Temperature Range: Reliable performance in operating conditions from -20°C to +90°C.
  • International Compliance: Designed and tested according to the stringent NEK 606 and IEC standards.
  • Strength and Durability: SHF2 thermosetting compound that offers superior mechanical protection.
  • Installation Flexibility: Optimized bending radius for mounting in complex spaces.

Applications

  • Critical Instrumentation Systems: Connecting sensors and transmitters in industrial environments.
  • Offshore Platforms and Ships: Ideal for marine applications due to its robustness and safety.
  • Alarm and Security Systems: Ensures the operation of emergency and fire detection circuits.
  • Control and Automation Circuits: Signal transmission for process control in industries.
  • Industrial Communication Networks: Used for secure communication between automation equipment.
  • Petrochemical Industry: Resistance for installations in refineries and chemical plants.
  • Intrinsically Safe Areas: Blue coating option for identification in intrinsically safe circuits.
  • Electrical and Control Panels: Internal wiring requiring high performance and fire safety.
  • Places with High Foot Traffic: Ideal for airports, hospitals, and tunnels, where safety is a priority.
  • Drilling and Production Equipment: Reliability for control systems in oil and gas operations.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeFire-Resistant Instrumentation Cables for Offshore & Marine Applications (NEK 606).
CórdobaS107 (Formerly S13) BU(i) 250 V
ApplicationsUsed for instrumentation, communication, control and alarm systems.
Electrical Parameters
Operating Voltage250 V
Maximum Conductor Resistance at 20°C0.75mm²: 26.3 Ω/km; 1.0mm²: 19.3 Ω/km; 1.5mm²: 12.9 Ω/km; 2.5mm²: 8.02 Ω/km
Mutual Capacitance0.75mm²: 85 nF/km; 1.0mm²: 95 nF/km; 1.5mm²: 100 nF/km; 2.5mm²: 110 nF/km
Nominal Inductance at 1kHz0.75mm²: 0.731 mH/km; 1.0mm²: 0.691 mH/km; 1.5mm²: 0.673 mH/km; 2.5mm²: 0.629 mH/km
Maximum L/R at 1kHz0.75mm²: 20 µH/Ω; 1.0mm²: 25 µH/Ω; 1.5mm²: 35 µH/Ω; 2.5mm²: 55 µH/Ω
Product Design
Conductor MaterialCircular braided, corrugated and tinned copper wire, class 2 or 5.
InsulationMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in mica tape + EPR upon request.
Formation of Pairs/TriosTwisted color-coded lanes joined together.
Individual ProtectionEach pair/trio is shielded by copper-based polyester tape in contact with a braided tinned copper drain wire wrapped in polyester tape.
Road Identification
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Court colors: Black, Light Blue, Brown, and Gray.

External CoverHalogen-free thermosetting compound, SHF2.
Cover ColorOuter sheath: Gray (for standard instrumentation) or Blue (for Intrinsically Safe - IS circuits)
Product characteristics
Fire resistantYes.
Flame RetardantYes.
Low Smoke EmissionYes.
Halogen-freeYes.
Minimum Radius of Curvature8 x External Diameter (during installation); 6 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Maximum Temperature in the Conductor+90°C.
Applicable Standards
NEK 606:2016IEC 60092-376
IEC 60092-360IEC 60331-21 (Fire resistance)
IEC 60332-1IEC 60332-3-22 (Flame retardancy)
IEC 60754-1,2IEC 61034-1,2 (Emission of smoke and gases)
IEC 60228
DIMENSIONAL TABLE

 

Construction (Number of elements x Number of paths in the element x Cross-sectional area in mm²)Nominal Insulation Thickness (mm)Nominal Coating Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
Cross-sectional area: 0.75 mm²
1 x 2 x 0.750.61.08.2105
2 x 2 x 0.750.61.210.5205
4 x 2 x 0.750.61.213.2290
7 x 2 x 0.750.61.416.0445
8 x 2 x 0.750.61.417.3495
12 x 2 x 0.750.61.621.1705
16 x 2 x 0.750.61.723.5915
19 x 2 x 0.750.61.824.81035
24 x 2 x 0.750.61.928.61320
32 x 2 x 0.750.62.031.71670
1 x 3 x 0.750.61.08.6120
2 x 3 x 0.750.61.212.0205
3 x 3 x 0.750.61.213.8300
4 x 3 x 0.750.61.315.1365
7 x 3 x 0.750.61.518.3560
8 x 3 x 0.750.61.519.5650
12 x 3 x 0.750.61.724.4915
16 x 3 x 0.750.61.827.31185
19 x 3 x 0.750.61.929.01360
24 x 3 x 0.750.62.133.71750
Cross-sectional area: 1.0 mm²
1 x 2 x 1.00.61.08.6125
2 x 2 x 1.00.61.211.1240
4 x 2 x 1.00.61.314.0345
7 x 2 x 1.00.61.516.9525
8 x 2 x 1.00.61.518.5600
12 x 2 x 1.00.61.622.3840
16 x 2 x 1.00.61.624.91095
19 x 2 x 1.00.61.826.51255
24 x 2 x 1.00.61.930.51605
32 x 2 x 1.00.62.033.82030
1 x 3 x 1.00.61.09.1140
3 x 3 x 1.00.61.314.7360
4 x 3 x 1.00.61.316.1440
7 x 3 x 1.00.61.619.7695
12 x 3 x 1.00.61.726.01115
16 x 3 x 1.00.61.829.21455
19 x 3 x 1.00.61.931.01675
24 x 3 x 1.00.62.136.12145
Cross-sectional area: 1.5 mm²
1 x 2 x 1.50.71.09.6155
2 x 2 x 1.50.71.312.6310
4 x 2 x 1.50.71.416.1450
7 x 2 x 1.50.71.619.4690
8 x 2 x 1.50.71.621.3780
12 x 2 x 1.50.71.725.71100
16 x 2 x 1.50.71.928.91450
19 x 2 x 1.50.72.030.51645
24 x 2 x 1.50.72.235.32115
32 x 2 x 1.50.72.339.12680
1 x 3 x 1.50.71.110.1175
2 x 3 x 1.50.71.314.5320
3 x 3 x 1.50.71.316.8470
4 x 3 x 1.50.71.418.4580
7 x 3 x 1.50.71.722.6910
8 x 3 x 1.50.71.723.51030
12 x 3 x 1.50.71.930.01475
16 x 3 x 1.50.72.033.61925
19 x 3 x 1.50.72.135.72210
24 x 3 x 1.50.72.441.72855
Cross-sectional area: 2.5 mm²
1 x 2 x 2.50.71.110.5190
1 x 3 x 2.50.71.311.0220
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.