DeepSea® Marine Instrumentation and Control Cable; NEK 606; S108 (S14) BU(c); 250V; Collective Shielding; Max. 1.50mm²; 1 to 32 pairs / trios / quads; MICA + HFEPR / SHF2; Fire Resistant; +90°C

DeepSea® Marine Instrumentation Cable – Fire Resistant SHF2 S108 (S14) BU(c) 250 V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK606 Instrumentation Cable: Safety and Performance in Critical EnvironmentsDesigned for maximum safety on offshore platforms and vessels. This cable keeps your instrumentation, control, and alarm systems functioning even during a fire, ensuring continuous communication and protecting lives.
  • Fire Safety: Fire-resistant, with low smoke emission and halogen-free for maximum protection.
  • Protected Signal: Collective shielding that prevents interference and ensures data transmission with complete reliability.
  • Robust Construction: SHF2 coating that operates from -20°C to +90°C, ideal for harsh environments.
  • Critical Applications: Essential for control, alarm, communication, and instrumentation systems in hazardous areas.
  • Certified Quality: It meets the stringent NEK 606 and IEC standards, ensuring performance and full compliance.
PRODUCT DESIGN
  • Conductors: Circular stranded copper wire, annealed and tinned, conforming to IEC 60228 class 2 or class 5.
  • Insulation: Mica tape + halogen-free HFEPR.
  • Collective Shielding: Pairs/trios/quads are grouped and collectively shielded by copper-based polyester tape in contact with a tinned and braided copper drain wire.
  • Outer Sheath: Halogen-free thermosetting compound, SHF2.
  • Road Identification:
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Court colors: Black, Light Blue, Brown, and Gray.

  • Outer sheath: Gray (for standard instrumentation) or Blue (for Intrinsically Safe - IS circuits)
DETAILS

Benefits

  • Superior Fire Resistance: Constructed with mica tape to maintain circuit integrity during fires.
  • Enhanced Security: Halogen-free compound with low smoke emission and flame retardant properties.
  • Reliable Signal Transmission: Collective shielding with polyester and copper tape for protection against interference.
  • High Durability: Tin-plated copper conductors that offer excellent corrosion resistance in marine environments.
  • Installation Flexibility: Allows for proper bending radii for fixed installation and during handling.
  • Compliance with Standards: It meets stringent international standards, including IEC and NEK 606.
  • Wide Temperature Range: Safe and reliable operation in temperatures ranging from -20°C to +90°C.
  • Robust Coating: External coating in SHF2, ensuring resistance in offshore and marine conditions.
  • Simplified Identification: Numbered pairs or trios to facilitate connection and maintenance of the systems.
  • Voltage Versatility: Designed for instrumentation and control systems with an operating voltage of 250V.

Applications

  • Offshore Platforms: Ideal for control and alarm systems in oil and gas exploration.
  • Vessels and Ships: Used in onboard communication and instrumentation systems.
  • Alarm and Security Systems: Critical application in fire detection and evacuation circuits.
  • Instrumentation Circuits: Connecting sensors and meters for monitoring industrial processes.
  • Control Systems: Signal transmission for automation and control in harsh environments.
  • Areas with Security Requirements: Perfect for confined spaces where low smoke and zero halogen are essential.
  • Various Maritime Applications: Suitable for drilling rigs, production vessels and other offshore structures.
  • Critical Communication Systems: It ensures continuous communication even under fire conditions.
  • Intrinsically Safe Circuits: Available in blue for installations requiring intrinsic safety.
  • Control and Command Panels: Interconnection of components in electrical panels in industrial and marine environments.
TECHNICAL DATA
General Information
BrandInnovcable DeepSea®
Product typeFire-resistant instrumentation cables for communication, control, and alarm systems.
CórdobaS108 (Formerly S14) BU(c) 250V
Electrical Parameters
Operating Voltage250 V
Maximum Conductor Resistance at 20°C0.75 mm²: 26.3 Ω/km
1.0 mm²: 19.3 Ω/km
1.5 mm²: 12.9 Ω/km
Mutual Capacitance0.75 mm²: 75 nF/km
1.0 mm²: 80 nF/km
1.5 mm²: 85 nF/km
Nominal Inductance at 1kHz0.75 mm²: 0.727 mH/km
1.0 mm²: 0.686 mH/km
1.5 mm²: 0.667 mH/km
Maximum L/R at 1kHz0.75 mm²: 20 µH/Ω
1.0 mm²: 25 µH/Ω
1.5 mm²: 35 µH/Ω
Product Design
Conductor MaterialTinned, annealed, and stranded circular copper wire.
Driver ClassClass 2 or Class 5 according to IEC 60228.
InsulationMica tape + Halogen-free EPR compound.
StringingTwisted color-coded lanes joined together.
Collective ShieldingPairs/trios are grouped and collectively shielded by copper-based polyester tape in contact with a braided tinned copper drain wire.
External CoverHalogen-free thermosetting compound, SHF2.
Cover Color
  • Outer sheath: Gray (for standard instrumentation) or Blue (for Intrinsically Safe - IS circuits)
Road Identification
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Court colors: Black, Light Blue, Brown, and Gray.

Product characteristics
Application AreaInstrumentation, communication, control and alarm systems.
Flame retardantYes.
Fire resistantYes.
Halogen-freeYes.
Low smoke emissionYes.
Radius of CurvatureDuring installation: 8 x External Diameter; After fixed installation: 6 x External Diameter.
Temperature Range-20 ° C to + 90 ° C.
Applicable Standards
NEK 606:2016IEC 60092-376
IEC 60092-360IEC 60331-21
IEC 60332-1IEC 60332 3 22
IEC 60754-1,2IEC 61034-1,2
DIMENSIONAL TABLE
Construction (Number of elements x Number of paths in the element x Cross-sectional area in mm²)Nominal Insulation Thickness (mm)Nominal Coating Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
2x2x0.750.61.110.2185
4x2x0.750.61.212.5240
7x2x0.750.61.415.0350
8x2x0.750.61.416.3395
12x2x0.750.61.519.5540
16x2x0.750.61.621.8690
19x2x0.750.61.723.2780
24x2x0.750.61.826.7985
32x2x0.750.62.129.61225
2x3x0.750.61.212.0205
3x3x0.750.61.213.1265
4x3x0.750.61.314.4320
7x3x0.750.61.317.4475
8x3x0.750.61.519.5590
12x3x0.750.61.622.9745
16x3x0.750.61.725.6965
19x3x0.750.61.827.21095
24x3x0.750.62.031.61405
2x2x1.00.61.110.7210
4x2x1.00.61.113.3285
7x2x1.00.61.416.0415
8x2x1.00.61.417.3465
12x2x1.00.61.620.8645
16x2x1.00.61.723.3825
19x2x1.00.61.824.7940
24x2x1.00.61.928.81200
32x2x1.00.62.331.81495
3x3x1.00.61.214.0310
4x3x1.00.61.415.3380
7x3x1.00.61.618.6570
12x3x1.00.61.624.4900
16x3x1.00.61.727.31160
19x3x1.00.61.929.01325
24x3x1.00.62.133.71700
2x2x1.50.71.212.1275
4x2x1.50.71.315.2380
7x2x1.50.71.518.4565
8x2x1.50.71.520.0640
12x2x1.50.71.724.3895
16x2x1.50.71.827.21150
19x2x1.50.71.928.61295
24x2x1.50.72.133.51670
32x2x1.50.72.337.02095
2x3x1.50.71.315.0310
3x3x1.50.71.316.0420
4x3x1.50.71.417.7515
7x3x1.50.71.621.5785
8x3x1.50.71.623.5930
12x3x1.50.71.828.51255
16x3x1.50.71.931.91630
19x3x1.50.72.033.81855
24x3x1.50.72.239.32375
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.