DeepSea® Marine Instrumentation and Control Cable; NEK 606; S110 (S16) BFOU-HCF(c); 250V; Collective Shielding; Armored; Max. 1.50mm²; 2 to 12 pairs; MICA + XLPE – EPR / LSOH / SHF2 / HC-FIRE / SHF1; Fire Resistant; +90°C

DeepSea® Marine Instrumentation Cable – Fire Resistant SHF2 S110 (S16) BFOU-HCF(c) 250 V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 "The exact total amount, applying the discounts for your volume bracket, will be automatically calculated in your cart."

DeepSea® S110 (S16) BFOU-HCF(c) Marine and Offshore Cable for Critical Safety InstrumentationDesigned to keep critical communication and control systems operating under the most extreme conditions. Ensures functionality under hydrocarbon fires, with low smoke and zero halogen emissions, protecting lives and valuable assets during operation.
  • Maximum Fire Safety: Operational in hydrocarbon fires, with low smoke and zero halogen emissions to protect lives.
  • Pure and Reliable Signal: Collective shielding blocks interference, ensuring the flawless transmission of data and commands.
  • Robust and Durable Construction: Braided armor and special coatings for maximum mechanical resistance in the offshore environment.
  • Versatility for Critical Systems: Ideal for alarms, control and emergency communication on platforms and ships.
  • Certified Reliability: Manufactured in accordance with NEK 606 and IEC standards, ensuring superior performance and complete peace of mind.
PRODUCT DESIGN
  • Conductors: Circular stranded tinned copper wire to IEC 60228 class 2 or class 5.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in Mica tape + EPR upon request.
  • Pairing: Color-coded cores twisted together.
  • Collective Shielding: Pairs/trios are arranged and collectively shielded by copper-based polyester tape in contact with a braided tinned copper drain wire.
  • Interior Coating: Halogen-free compound.
  • Armor: Mesh of tinned copper wire.
  • External Coating 1: Halogen-free thermoset compound, SHF2.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Tape: Overlapping fiberglass tape.
  • External Coating 2: Flame-retardant, halogen-free thermoplastic compound, type SHF1, in gray (blue for intrinsic safety).
DETAILS

Benefits

  • Maximum Fire Safety: Fire resistant, flame retardant and halogen-free.
  • Critical Operation Guaranteed: It keeps the systems running even under a hydrocarbon fire at 1100°C.
  • Low Smoke Emission: The cable's composition ensures low smoke emission (LSZH), facilitating evacuation.
  • Corrosion Protection: Tinned copper conductors for increased durability in marine environments.
  • Effective Collective Shielding: Protects instrumentation signals against electromagnetic interference.
  • Robust Construction: Copper wire braid armor for excellent mechanical protection.
  • Wide Temperature Range: Reliable operation in temperatures ranging from -20°C to +90°C.
  • Compliance with Strict Standards: Meets IEC and NEK 606 standards for offshore applications.
  • High Performance Insulation: XLPE composite and mica tape ensure circuit integrity.
  • Durable Double Coating: SHF2 and SHF1 covers for maximum protection against the environment.

Applications

  • Emergency Alarm Systems: Ideal for critical fire alarm and detection circuits.
  • Safety Instrumentation: Power supply for instruments in emergency shutdown (ESD) systems.
  • Critical Control Circuits: Used in control systems that must operate during a fire.
  • Communication Systems: Essential for emergency communication systems on platforms and ships.
  • Offshore Platforms: Designed for installation on oil and gas platforms.
  • Naval and Maritime Industry: Application in ships, drilling rigs and other maritime vessels.
  • Production Units (FPSOs): It ensures the operation of essential systems in floating production units.
  • Emergency Lighting Systems: Ensures the proper functioning of lighting on escape routes.
  • Safety Valve Control: Used in the automation of valves that need to operate in emergencies.
  • Areas with Fire Risk: Perfect for any environment where operational continuity during a fire is vital.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeFire Resistant Instrumentation Cables, Offshore & Marine (BFOU-HCF(c) 250V)
Electrical Parameters (for a 1.5mm² cross-section)
Operating Voltage250 V
Maximum Conductor Resistance at 20°C12.9 Ω/km
Mutual Capacitance85 nF/km
Nominal Inductance at 1kHz0.667 mH/km
Product Design
Conductor MaterialCircular stranded tinned copper wire, class 2 or class 5 according to IEC 60228.
InsulationMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in mica tape + EPR upon request.
Pair Training (Twinning)Color-coded lanes twisted together.
Collective ShieldingPairs/trios are grouped and collectively shielded by polyester tape with a copper backing in contact with a tinned copper drain wire.
Inner Cover (Bedding)Halogen-free compound.
ArmorTinned copper wire mesh.
First Outer CoverHalogen-free thermosetting compound, SHF2.
Hydrocarbon Fire ProtectionExtruded thermoplastic compound for fire protection.
Protective TapeOverlapping fiberglass tape.
Second Outer CoverFlame-retardant, halogen-free thermoplastic compound, type SHF1.
Color of the Exterior CoverGray (Blue for intrinsically safe applications).
Road IdentificationPairs/trios numbered with numbered tape or by numbers printed directly on the insulated conductors.
Product characteristics
Application AreaEmergency instrumentation, communication, control, and alarm systems that need to be operational during a hydrocarbon fire at 1100°C.
Minimum Radius of Curvature20 × External Diameter (during installation); 12 × External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Flame retardantYes.
fire resistantYes.
Halogen-freeYes.
Low smoke emissionYes.
Dimensions and Weight (Examples for 1.5mm²)
Construction2x2x1.5 mm²
Nominal Insulation Thickness0.7 mm
Nominal Diameter Over the Inner Cover13.0 mm
Nominal Diameter on the First Layer16.4 mm
Nominal Overall Outside Diameter44.5 mm
Nominal Weight2400kg/km
Applicable Standards
NEK 606:2016IEC 60331-21
IEC 60092-376IEC 60332-1
IEC 60092-360IEC 60332 3 22
IEC 60228IEC 60754-1,2
IEC 61034-1,2-
DIMENSIONAL TABLE
Construction (Number of elements x Number of paths x Section mm²)Nominal Insulation Thickness (mm)Nominal Diameter over the First Layer (mm)Nominal Diameter over the Second Layer (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Radius of Curvature
2x2x1.50.713.016.444.5240020 oz (installation); 12 oz (fixed)
4x2x1.50.715.019.946.5265020 oz (installation); 12 oz (fixed)
8x2x1.50.720.525.353.0357020 oz (installation); 12 oz (fixed)
12x2x1.50.723.529.657.0416020 oz (installation); 12 oz (fixed)
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.