DeepSea® Marine Instrumentation and Control Cable; NEK 606; S110 (S16) BFOU-HCF(c); 250V; Collective Shielding; Armored; Max. 1.50mm²; 2 to 12 pairs; MICA + XLPE – EPR / LSOH / SHF2 / HC-FIRE / SHF1; Fire Resistant; +90°C
DeepSea® Marine Instrumentation Cable – Fire Resistant SHF2 S110 (S16) BFOU-HCF(c) 250 V
💡 "The exact total amount, applying the discounts for your volume bracket, will be automatically calculated in your cart."
- Maximum Fire Safety: Operational in hydrocarbon fires, with low smoke and zero halogen emissions to protect lives.
- Pure and Reliable Signal: Collective shielding blocks interference, ensuring the flawless transmission of data and commands.
- Robust and Durable Construction: Braided armor and special coatings for maximum mechanical resistance in the offshore environment.
- Versatility for Critical Systems: Ideal for alarms, control and emergency communication on platforms and ships.
- Certified Reliability: Manufactured in accordance with NEK 606 and IEC standards, ensuring superior performance and complete peace of mind.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Brand | Innovcable DeepSea® |
| Product type | Fire Resistant Instrumentation Cables, Offshore & Marine (BFOU-HCF(c) 250V) |
| Electrical Parameters (for a 1.5mm² cross-section) | |
| Operating Voltage | 250 V |
| Maximum Conductor Resistance at 20°C | 12.9 Ω/km |
| Mutual Capacitance | 85 nF/km |
| Nominal Inductance at 1kHz | 0.667 mH/km |
| Product Design | |
| Conductor Material | Circular stranded tinned copper wire, class 2 or class 5 according to IEC 60228. |
| Insulation | Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in mica tape + EPR upon request. |
| Pair Training (Twinning) | Color-coded lanes twisted together. |
| Collective Shielding | Pairs/trios are grouped and collectively shielded by polyester tape with a copper backing in contact with a tinned copper drain wire. |
| Inner Cover (Bedding) | Halogen-free compound. |
| Armor | Tinned copper wire mesh. |
| First Outer Cover | Halogen-free thermosetting compound, SHF2. |
| Hydrocarbon Fire Protection | Extruded thermoplastic compound for fire protection. |
| Protective Tape | Overlapping fiberglass tape. |
| Second Outer Cover | Flame-retardant, halogen-free thermoplastic compound, type SHF1. |
| Color of the Exterior Cover | Gray (Blue for intrinsically safe applications). |
| Road Identification | Pairs/trios numbered with numbered tape or by numbers printed directly on the insulated conductors. |
| Product characteristics | |
| Application Area | Emergency instrumentation, communication, control, and alarm systems that need to be operational during a hydrocarbon fire at 1100°C. |
| Minimum Radius of Curvature | 20 × External Diameter (during installation); 12 × External Diameter (fixed installation). |
| Temperature Range | -20 ° C to + 90 ° C. |
| Flame retardant | Yes. |
| fire resistant | Yes. |
| Halogen-free | Yes. |
| Low smoke emission | Yes. |
| Dimensions and Weight (Examples for 1.5mm²) | |
| Construction | 2x2x1.5 mm² |
| Nominal Insulation Thickness | 0.7 mm |
| Nominal Diameter Over the Inner Cover | 13.0 mm |
| Nominal Diameter on the First Layer | 16.4 mm |
| Nominal Overall Outside Diameter | 44.5 mm |
| Nominal Weight | 2400kg/km |
| Applicable Standards | |
| NEK 606:2016 | IEC 60331-21 |
| IEC 60092-376 | IEC 60332-1 |
| IEC 60092-360 | IEC 60332 3 22 |
| IEC 60228 | IEC 60754-1,2 |
| IEC 61034-1,2 | - |
| Construction (Number of elements x Number of paths x Section mm²) | Nominal Insulation Thickness (mm) | Nominal Diameter over the First Layer (mm) | Nominal Diameter over the Second Layer (mm) | Nominal Outside Diameter (mm) | Nominal Weight (kg/km) | Radius of Curvature |
| 2x2x1.5 | 0.7 | 13.0 | 16.4 | 44.5 | 2400 | 20 oz (installation); 12 oz (fixed) |
| 4x2x1.5 | 0.7 | 15.0 | 19.9 | 46.5 | 2650 | 20 oz (installation); 12 oz (fixed) |
| 8x2x1.5 | 0.7 | 20.5 | 25.3 | 53.0 | 3570 | 20 oz (installation); 12 oz (fixed) |
| 12x2x1.5 | 0.7 | 23.5 | 29.6 | 57.0 | 4160 | 20 oz (installation); 12 oz (fixed) |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.