DeepSea® Marine Instrumentation and Control Cable; NEK 606; S102 (S2 or S2/S6) RFOU(c); 250V; Armored; Max. 2.50mm²; 1 to 37 pairs / triplets / quads; XLPE – EPR / LSOH / SHF2 – SHF MUD; Flame Retardant; +90°C

DeepSea® Marine Instrumentation Cable – Flame Retardant S102 (S2 or S2/S6) RFOU(c) 250V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK606 RFOU(c) cable for offshore and marine instrumentationDesigned for the most demanding offshore environments, this cable ensures maximum reliability in critical instrumentation, communication, and control systems. Its robust construction and superior materials guarantee secure and uninterrupted data transmission.
  • Superior Security: Flame retardant, low smoke and halogen-free for maximum protection.
  • Reliable Transmission: Collective shielding that protects against interference, ensuring data accuracy.
  • Robust Construction: Copper braid armor and SHF2 and SHF MUD coating resistant to mud and oils.
  • Critical Applications: Ideal for alarm, control and communication on ships and offshore platforms.
  • Certified Quality: Compliant with NEK 606 and IEC standards, ensuring superior performance and extended service life.
PRODUCT DESIGN
  • Conductors: Stranded, corrugated, tinned copper wire, circular, class 2 or class 5 according to IEC 60228.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in EPR upon request.
  • Collective Shielding: Pairs/trios are grouped together and collectively shielded by copper-based polyester tape in contact with a braided tinned copper drain wire.
  • Inner Coating: Halogen-free compound.
  • Armor: Braid of tinned copper wire.
  • Outer Coating: Halogen-free thermosetting compound, SHF2 (formerly TYPE S2). Halogen-free mud-resistant thermosetting compound, SHF MUD (formerly TYPE S2/S6).
  • Road Identification:
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Court colors: Black, Light Blue, Brown, and Gray.

  • Outer sheath: Gray (for standard instrumentation) or Blue (for Intrinsically Safe - IS circuits). Other colors, such as Black for greater UV resistance, available upon request.
DETAILS

Benefits

  • Mud resistance: Designed to withstand exposure to mud and drilling fluids.
  • Enhanced Security: Halogen-free, with low smoke emission and flame retardant.
  • Electromagnetic Protection: Collective shielding that guarantees the integrity of signals against interference.
  • Wide temperature range: Safe operation in temperatures ranging from -20°C to +90°C.
  • Robust Construction: Armor made of tinned copper wire braid for enhanced mechanical protection.
  • Durability in harsh environments: Ideal for installations in demanding offshore and marine environments.
  • Installation Flexibility: Suitable for bending radii up to 6 times the outside diameter in fixed installations.
  • High Reliability: Tinned copper conductors that offer excellent conductivity and corrosion resistance.
  • Compliance with Standards: Manufactured in accordance with stringent IEC and NEK 606 standards.
  • Superior insulation: Insulation in halogen-free EPR or XLPE for greater safety and performance.

Applications

  • Offshore Platforms: Used in instrumentation, communication, control, and alarm systems.
  • Oil and Gas Industry: Fixed installations in safe areas and areas at risk of explosion (Ex).
  • Ships and vessels: Applications in emergency and critical onboard systems.
  • Telecommunications Systems: It ensures the reliable transmission of data and signals in marine environments.
  • Process Control: Connecting sensors and actuators in offshore industrial automation systems.
  • Areas exposed to fluids: Installations in locations subject to cleaning and drilling fluids.
  • Emergency systems: Power supply for critical systems that need to operate during adverse conditions.
  • Cable trays: Ideal for permanent installation in cable trays in outdoor environments.
  • Drilling probes: Use in drilling equipment on oil and gas platforms.
  • Floating production units: Essential in storage and transfer systems (FPSO).
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeOffshore & Marine Instrumentation Cables
CórdobaS102 (RFOU(c) 250V)
ApplicationsUsed for instrumentation, communication, control and alarm systems in offshore and marine environments.
Electrical Parameters
Operating Voltage250V
Maximum Conductor Resistance (@20°C)
  • 0.75 mm²: 26.3 Ω/km
  • 1.0 mm²: 19.3 Ω/km
  • 1.5 mm²: 12.9 Ω/km
  • 2.5 mm²: 8.02 Ω/km
Mutual Capacitance
  • 0.75 mm²: 80 nF/km
  • 1.0 mm²: 90 nF/km
  • 1.5 mm²: 100 nF/km
  • 2.5 mm²: 110 nF/km
Nominal Inductance (@1KHz)
  • 0.75 mm²: 0.682 mH/km
  • 1.0 mm²: 0.645 mH/km
  • 1.5 mm²: 0.632 mH/km
  • 2.5 mm²: 0.593 mH/km
Maximum L/R Ratio (@1KHz)
  • 0.75 mm²: 20 μH/Ω
  • 1.0 mm²: 25 μH/Ω
  • 1.5 mm²: 35 μH/Ω
  • 2.5 mm²: 50 μH/Ω
Product Design
Conductor MaterialBraided, corrugated, and tinned copper wires.
Driver ClassAccording to IEC 60228 class 2 or class 5.
Insulation MaterialHalogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in EPR upon request.
Road Identification
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Court colors: Black, Light Blue, Brown, and Gray.

Collective ShieldingPolyester tape with a copper base in contact with a tinned copper drain wire.
Inner Cover (Bedding)Halogen-free compound.
ArmorBraid of tinned copper wire.
Exterior Roofing MaterialSHF2 thermoset compound (halogen-free) or SHF MUD (halogen-free and mud-resistant).
Cover ColorOuter sheath: Gray (for standard instrumentation) or Blue (for Intrinsically Safe - IS circuits). Other colors, such as Black for greater UV resistance, available upon request.
Product characteristics
Flame RetardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Low Smoke EmissionYes, in accordance with IEC 61034-1,2.
Halogen-freeYes, in accordance with IEC 60754-1,2.
Mud Resistant (MUD)Yes (only for the version with SHF MUD cover).
Minimum Radius of Curvature8 × External Diameter (during installation); 6 × External Diameter (fixed installation).
Operating Temperature Range-20 °C to +90 °C.
Applicable Standards
Design and ConstructionNEK 606:2016, IEC 60092-376
MaterialsIEC 60092-360
DriversIEC 60228
Behavior in FireIEC 60332-1, IEC 60332-3-22
Smoke and Halogen EmissionIEC 61034-1,2, IEC 60754-1,2
DIMENSIONAL TABLE
Construction (Number of elements x Number of paths x Section (mm²))Nominal Insulation Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
Cross-sectional area: 0.75 mm²
1x2x0.750.61.11.111.1200
2x2x0.750.61.31.115.0295
3x2x0.750.61.11.315.6355
4x2x0.750.61.11.316.4390
5x2x0.750.61.41.117.8540
6x2x0.750.61.41.119.1610
7x2x0.750.61.41.119.1625
8x2x0.750.61.51.120.7680
9x2x0.750.61.51.121.8745
10x2x0.750.61.61.122.9760
12x2x0.750.61.61.123.4810
14x2x0.750.61.61.124.5875
15x2x0.750.61.71.126.1960
16x2x0.750.61.71.126.51010
18x2x0.750.61.81.127.91080
19x2x0.750.61.81.128.21115
20x2x0.750.61.81.129.21210
21x2x0.750.61.81.130.01255
23x2x0.750.61.91.130.61355
24x2x0.750.61.91.131.91370
27x2x0.750.61.21.932.91480
30x2x0.750.61.22.034.11605
33x2x0.750.61.22.035.31725
37x2x0.750.61.22.136.91950
1x3x0.750.61.11.211.7230
2x3x0.750.61.11.314.5360
3x3x0.750.61.11.316.2415
4x3x0.750.61.11.417.6540
5x3x0.750.61.11.419.1645
6x3x0.750.61.11.521.1755
7x3x0.750.61.11.521.1780
8x3x0.750.61.61.122.6845
9x3x0.750.61.61.123.9945
10x3x0.750.61.11.725.7960
12x3x0.750.61.71.126.41080
14x3x0.750.61.11.727.51150
15x3x0.750.61.11.828.51230
16x3x0.750.61.11.829.21310
18x3x0.750.61.11.930.71405
19x3x0.750.61.11.931.01475
20x3x0.750.61.91.131.81560
21x3x0.750.61.91.232.71640
23x3x0.750.61.22.034.11795
24x3x0.750.62.01.234.61830
27x3x0.750.61.22.136.82040
30x3x0.750.62.11.238.32210
32x3x0.750.61.22.239.52345
Cross-sectional area: 1.0 mm²
1x2x1.00.61.21.111.7225
2x2x1.00.61.11.313.4335
3x2x1.00.61.31.116.3470
4x2x1.00.61.41.117.4535
5x2x1.00.61.41.118.7610
6x2x1.00.61.51.120.2700
7x2x1.00.61.51.120.2720
8x2x1.00.61.51.121.8775
9x2x1.00.61.61.123.2850
10x2x1.00.61.61.124.1880
12x2x1.00.61.11.624.7980
14x2x1.00.61.11.726.01030
15x2x1.00.61.11.827.81125
16x2x1.00.61.11.828.21175
18x2x1.00.61.81.129.51255
19x2x1.00.61.11.829.81295
20x2x1.00.61.11.931.11420
21x2x1.00.61.11.931.91475
23x2x1.00.61.21.932.71610
24x2x1.00.61.22.034.31620
27x2x1.00.61.22.035.01745
30x2x1.00.61.22.136.71980
32x2x1.00.61.22.138.02130
37x2x1.00.61.22.239.32305
1x3x1.00.61.11.212.0250
2x3x1.00.61.11.417.0520
3x3x1.00.61.11.417.4540
4x3x1.00.61.11.418.7625
5x3x1.00.61.11.520.2745
6x3x1.00.61.11.622.4875
7x3x1.00.61.11.622.4905
8x3x1.00.61.11.623.8980
9x3x1.00.61.11.725.41080
10x3x1.00.61.11.727.11150
12x3x1.00.61.11.828.11265
14x3x1.00.61.11.829.21355
15x3x1.00.61.11.830.11440
16x3x1.00.61.11.931.11570
18x3x1.00.61.21.932.81675
19x3x1.00.61.22.033.31750
20x3x1.00.61.22.034.11880
21x3x1.00.61.22.034.81950
23x3x1.00.61.22.136.62215
24x3x1.00.61.22.137.32200
27x3x1.00.61.22.239.22425
30x3x1.00.61.22.240.82630
32x3x1.00.61.22.342.12790
Cross-sectional area: 1.5 mm²
1x2x1.50.71.11.212.7260
2x2x1.50.71.11.415.4420
3x2x1.50.71.11.417.6585
4x2x1.50.71.11.418.8635
5x2x1.50.71.11.521.1770
6x2x1.50.71.11.622.8890
7x2x1.50.71.11.622.8925
8x2x1.50.71.11.623.7975
9x2x1.50.71.11.726.31060
10x2x1.50.71.11.727.41130
12x2x1.50.71.11.828.31270
14x2x1.50.71.11.829.51325
15x2x1.50.71.11.931.61445
16x2x1.50.71.11.932.11575
18x2x1.50.71.22.034.21670
19x2x1.50.71.22.034.51765
20x2x1.50.71.22.136.01895
21x2x1.50.71.22.137.32050
23x2x1.50.71.22.137.92185
24x2x1.50.71.22.239.82200
27x2x1.50.71.22.240.62390
30x2x1.50.71.22.342.12600
33x2x1.50.71.22.343.62805
37x2x1.50.71.42.445.43080
1x3x1.50.71.11.213.2295
2x3x1.50.71.11.417.0490
3x3x1.50.71.11.519.5685
4x3x1.50.71.11.520.9785
5x3x1.50.71.11.621.0820
6x3x1.50.71.11.722.8960
7x3x1.50.71.11.725.11135
8x3x1.50.71.11.727.01270
9x3x1.50.71.11.828.91445
10x3x1.50.71.11.931.11450
12x3x1.50.71.11.931.51710
14x3x1.50.71.22.033.81815
15x3x1.50.71.22.034.81930
16x3x1.50.71.22.136.02110
18x3x1.50.71.22.138.12305
19x3x1.50.71.22.238.62375
20x3x1.50.71.22.239.62580
21x3x1.50.71.22.240.42680
23x3x1.50.71.22.342.02925
24x3x1.50.71.22.342.73140
27x3x1.50.71.42.445.33250
30x3x1.50.71.42.547.43555
32x3x1.50.71.42.548.63745
Cross-sectional area: 2.5 mm²
1x2x2.50.71.11.213.5300
2x2x2.50.71.11.418.9650
3x2x2.50.71.11.519.9720
4x2x2.50.71.11.521.1820
5x2x2.50.71.11.623.0965
6x2x2.50.71.11.624.81105
7x2x2.50.71.11.624.81150
8x2x2.50.71.11.727.01255
9x2x2.50.71.11.828.81385
10x2x2.50.71.11.830.01430
12x2x2.50.71.31.931.01545
14x2x2.50.71.21.932.71730
15x2x2.50.71.22.035.01885
16x2x2.50.71.22.035.61970
18x2x2.50.71.22.137.92235
19x2x2.50.71.22.138.32315
20x2x2.50.71.22.239.92530
21x2x2.50.71.22.241.02630
23x2x2.50.71.22.341.82750
24x2x2.50.71.22.343.72850
27x2x2.50.71.42.445.13150
30x2x2.50.71.42.546.83435
32x2x2.50.71.42.548.53715
37x2x2.50.71.42.650.24040
1x3x2.50.71.11.314.3360
2x3x2.50.71.11.520.5785
3x3x2.50.71.11.521.2875
4x3x2.50.71.11.622.91035
5x3x2.50.71.11.624.81205
6x3x2.50.71.11.827.81430
7x3x2.50.71.11.827.81505
8x3x2.50.71.11.829.61625
9x3x2.50.71.11.931.71855
10x3x2.50.71.22.034.41890
12x3x2.50.71.22.035.52110
14x3x2.50.71.22.137.62445
15x3x2.50.71.22.238.92620
16x3x2.50.71.22.240.02755
18x3x2.50.71.22.342.03010
19x3x2.50.71.22.342.43125
20x3x2.50.71.22.343.53360
21x3x2.50.71.42.444.93555
23x3x2.50.71.42.546.73885
24x3x2.50.71.42.547.53870
27x3x2.50.71.42.650.04280
30x3x2.50.71.42.752.34695
32x3x2.50.71.42.753.84960
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.