DeepSea® Marine Instrumentation and Control Cable; NEK 606; S111 RX / TX; 250 V; Max. 2,50 mm²; 1 conductor; XLPE / EPR; Flame Retardant; +90°C

DeepSea® Marine Instrumentation Cable – Flame Retardant S111 RX / TX 250V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Offshore Instrumentation Cable S111 for Maximum SafetyDeveloped for the harshest conditions in offshore and marine environments. Ensures that critical control and emergency systems remain operational during a fire, guaranteeing data and power transmission when it is most crucial.
  • Maximum Fire Safety: Fire-resistant, with low smoke emission and halogen-free, protecting lives and equipment.
  • Superior Electrical Performance: Excellent signal transmission with optimal capacitance and inductance performance for accurate data.
  • Robust and Flexible Construction: Copper conductors and XLPE insulation for high durability and easy installation in confined spaces.
  • Wide Operating Range: Reliable operation in temperatures from -20°C to +90°C, ensuring maximum versatility in any scenario.
  • Meets the requirements of NEK 606: Compliant with stringent IEC and NEK 606 standards, attesting to its quality and safety.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed circular stranded copper to IEC 60228 class 5 or class 2.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in EPR upon request.
DETAILS

Benefits

  • Superior Fire Safety: Fire resistant, flame retardant and halogen-free.
  • Low Smoke Emission: It ensures greater visibility for safe evacuation in case of fire.
  • Critical Business Continuity: It keeps essential systems functioning even under hydrocarbon fire.
  • High Durability: Tin-plated copper conductors for maximum corrosion resistance in marine environments.
  • High Performance Insulation: XLPE compound for excellent electrical and thermal insulation.
  • Wide Temperature Range: Safe and reliable operation in temperatures from -20°C to +90°C.
  • Installation Flexibility: Braided conductors that facilitate handling in confined spaces.
  • Compliance with Strict Standards: It meets the stringent requirements of the international standards NEK 606 and IEC.
  • Life and Asset Protection: Designed to maximize the safety of critical personnel and equipment.
  • Guaranteed Reliability: Ideal for systems where failure is not an option, ensuring peace of mind.

Applications

  • Oil and Gas Platforms: Critical installations in offshore and marine environments.
  • Emergency Control Systems: Circuits that must operate during fires for process control.
  • Essential Energy Supply: Power supply for security and firefighting equipment.
  • Emergency Lighting Systems: It ensures the illumination of escape routes and safe areas.
  • Ships and Floating Production Storage and Offloading (FPSO) Units: Applications in vessels and production and storage units.
  • Critical Instrumentation Circuits: Connecting sensors and meters in high-risk areas.
  • Alarm and Communication Systems: It ensures the operation of vital warning and communication systems.
  • Naval and Petrochemical Industry: Environments that require maximum safety against fire and corrosion.
  • Valve and Actuator Control: For control systems in emergency situations.
  • Survival Equipment: Power supply for essential evacuation and rescue systems.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeOffshore & Marine Cables NEK606, Instrumentation Cables
CórdobaS111 RX/TX 250V
Applications
Application AreaUsed for emergency control, power, and lighting systems that need to be operational during a hydrocarbon fire at 1100°C.
Product Design
Conductor MaterialBraided, ringed, and tinned copper.
Driver ClassClass 5 or Class 2, according to IEC 60228.
Base Material for Pathway IsolationHalogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in EPR upon request.
Insulation ColorBlue, brown, black, or gray.
Electrical Parameters
Operating Voltage250 V
Maximum Conductor Resistance (@20°C)26.3 Ω/km (0.75mm²), 19.3 Ω/km (1.0mm²), 12.9 Ω/km (1.5mm²), 8.02 Ω/km (2.5mm²)
Mutual Capacitance85 nF/km (0.75mm²), 95 nF/km (1.0mm²), 100 nF/km (1.5mm²), 110 nF/km (2.5mm²)
Nominal Inductance (@1KHz)0.731 mH/km (0.75mm²), 0.691 mH/km (1.0mm²), 0.673 mH/km (1.5mm²), 0.629 mH/km (2.5mm²)
Maximum L/R Ratio (@1KHz)20 μH/Ω (0.75mm²), 25 μH/Ω (1.0mm²), 35 μH/Ω (1.5mm²), 55 μH/Ω (2.5mm²)
Mechanical and Thermal Properties
Minimum Radius of Curvature8 × External Diameter (during installation); 6 × External Diameter (fixed installation)
Temperature Range-20 ° C to + 90 ° C
Product characteristics
Fire resistantYes
Flame RetardantYes
Halogen-freeYes
Low Smoke EmissionYes
Dimensions and Weight (Single-way construction)
Section 1 x 0.75 mm²Insulation Thickness: 0.6 mm, Outer Diameter: 2.31 mm, Weight: 107 kg/km
Section 1 x 1.0 mm²Insulation Thickness: 0.6 mm, Outer Diameter: 2.49 mm, Weight: 120 kg/km
Section 1 x 1.5 mm²Insulation Thickness: 0.7 mm, Outer Diameter: 2.99 mm, Weight: 171 kg/km
Section 1 x 2.5 mm²Insulation Thickness: 0.7 mm, Outer Diameter: 3.41 mm, Weight: 209 kg/km
Applicable Standards
RulesIEC 60092-354, IEC 60092-360, IEC 60331-21, IEC 60332-1, IEC 60332-3-22, IEC 60754-1,2, IEC 61034-1,2, NEK 606:2016
DIMENSIONAL TABLE

 

ConstructionNominal Cross-Sectional Area ()Nominal Conductor Diameter (mm)Nominal Insulation Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight ()Maximum Resistance @20°C ()Mutual Capacitance ()Nominal Inductance @1KHz ()Maximum L/R @1KHz ()Operating Voltage (V)
1 x 0.750.751.10.62.3110726.3850.73120250
1 x 1.01.01.30.62.4912019.3950.69125250
1 x 1.51.51.60.72.9917112.91000.67335250
1 x 2.52.52.00.73.412098.021100.62955250
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.