DeepSea® Marine Instrumentation and Control Cable; NEK 606; P109 TFLI (P16 IFLI); 250 V; Armored; 2 x 1 x 2,50 mm²; XLPE / LSOH / SHF1; Flame Retardant; +90°C

DeepSea® Marine Instrumentation Cable – Flame Retardant SHF2 P109 TFLI (P16 IFLI) 250 V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

P109 TFLI Offshore Cable for Safe and Reliable InstallationsDesigned for residential and office areas, these cables are flame-retardant, low-smoke, and halogen-free. Ensure maximum protection and performance in your facilities with a product that meets the most stringent naval safety standards.
  • Superior Human Security: Halogen-free, ideal for inhabited areas, ensuring low toxicity in case of fire.
  • Performance at Extremes: It operates reliably over a wide temperature range, from -20°C to +90°C.
  • Robust Construction: Copper conductors and XLPE insulation for maximum durability and electrical conductivity.
  • Essential Protection: Shielding with aluminum tape to protect against interference and ensure signal integrity.
  • International Standard NEK 606: It meets the most demanding offshore standards, guaranteeing quality and reliability.
PRODUCT DESIGN
  • Conductors: Flexible bare copper wires conforming to IEC 60228 class 5. Class 2 available upon request.
  • Insulation: XLPE
  • Inner Cover: Halogen-free thermoplastic compound
  • Metallic Shielding: Aluminized tape with flexible drain conductor, formed by tinned electrolytic copper wires. 
  • Outer Sheath: Halogen-free thermoplastic compound, SHF1
DETAILS

Benefits

  • Enhanced Security: The cable is flame retardant, reducing the risk of fire spreading.
  • Protection in Case of Fire: It has low smoke emission and is halogen-free, ensuring greater visibility and fewer toxic gases during an evacuation.
  • Reliable Signal: Shielding with aluminum tape and a ground conductor offer effective protection against electromagnetic interference.
  • Wide Temperature Range: Designed to operate reliably in temperatures ranging from -20°C to +90°C.
  • Easy Installation: The optimized bending radius allows for flexible installation even in locations with limited space.
  • High Durability: The SHF1 outer coating offers excellent mechanical protection in marine and offshore environments.
  • Superior Insulation: XLPE insulation ensures optimal electrical properties and thermal resistance.
  • Certified Quality: Built in accordance with stringent international standards IEC and NEK 606.
  • Efficient Conductivity: It uses braided copper conductors, ensuring excellent electrical performance.
  • Equipment Protection: Because it is halogen-free, it does not emit corrosive gases that could damage sensitive electronic instruments.

Applications

  • Accommodations and Cabins: Ideal for electrical installations in living areas and bedrooms on boats and platforms.
  • Offices and Control Rooms: Used in instrumentation systems and control circuits in onboard administrative areas.
  • Common Areas: It is applicable in corridors, cafeterias, and other common areas in offshore installations.
  • Instrumentation Panels: Perfect for connecting sensors and devices in control and automation panels.
  • Signaling Systems: Used in signaling and alarm circuits where fire safety is an essential requirement.
  • Fixed Installations: Suitable for general use in fixed electrical installations in marine environments.
  • Low Voltage Equipment: Power supply and control for equipment operating at voltages up to 250 V.
  • Modernization Projects: A safe solution for upgrading electrical systems on existing ships and platforms.
  • Environments with Sensitive Electronics: Recommended for locations where protection against corrosive gases is crucial.
  • Naval Infrastructure: Used in the construction and maintenance of electrical systems for various vessels.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeOffshore & Marine Instrumentation Cable P109 TFLI (250 V)
ApplicationsUsed in common areas and offices. They are flame retardant, with low smoke emission and halogen-free.
Electrical Parameters
Operating Voltage250 V
Maximum Conductor Resistance7.41 Ω/km at 20°C
Direct Current Capacity (2-Way)26 A @ 45°C
Short-Circuit Current (1s)360 A
Product Design
Construction2x1x2.5 mm²
Nominal Cross Section2.5 mm²
Conductor MaterialBare copper wires braided in a circular pattern.
Driver ClassClass 5, according to IEC 60228. Class 2 available upon request.
InsulationXLPE
Nominal Insulation Thickness0.7 mm
Inner Cover (Bedding)Halogen-free thermoplastic compound.
Metal Mesh (Shield)Longitudinal aluminum tape (0.2 mm thick) in contact with a braided copper grounding conductor.
External CoverHalogen-free thermoplastic compound, SHF1.
Nominal Coating ThicknessExternal: 1.2 mm; Internal: 1.1 mm
Cover ColorGray
Mechanical and Thermal Properties
Nominal Outside Diameter10.0 mm
Nominal Weight180kg/km
Minimum Radius of Curvature8 x External Diameter (during installation); 6 x External Diameter (fixed installation)
Temperature Range-20 ° C to + 90 ° C
Fire Characteristics
Flame RetardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1,2.
Low Smoke EmissionYes, in accordance with IEC 61034-1,2.
Applicable Standards
Construction StandardNEK 606:2016
Reference StandardsIEC 60092-376, IEC 60092-360, IEC 60332-1, IEC 60332-3-22, IEC 60754-1,2, IEC 61034-1,2, IEC 60228 Class 5.
DIMENSIONAL TABLE
Construction
Number of elements x Number of paths in the element x Cross-sectional area (mm²)2×1×2.5
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.