DeepSea® Marine Cable NEK 606 P106 (P6 or P6/P13) BFOU/TFOU; 3.6/6kV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 03 conductors; MICA + XLPE / LSOH / SHF2 – SHF2 MUD; Fire Resistant; +90°C

DeepSea® Medium Voltage Marine Cable – Fire Resistant SHF2 P106 (P6 or P6/P13) BFOU/TFOU 3.6/6kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

BFOU/TFOU 3.6/6kV NEK606 Cables: Safety and Extreme PerformanceDesigned for the most critical installations in marine and offshore environments. Offers safety, being resistant to fire, mud and halogen-free, guaranteeing protection and operational continuity in your medium voltage installation.
  • Critical Fire Protection: Flame resistant, low smoke and halogen-free for maximum safety in emergencies.
  • Durability in Harsh Environments: Resistant to mud and extreme temperatures (-20°C to +90°C), ensuring continuous performance.
  • DeepSea® NEK 606 Quality: Produced under the strictest IEC standards, ensuring the highest reliability and superior performance.
  • Medium Voltage Applications: Ideal for power supply in fixed installations on platforms, ships and offshore units.
  • Smart Investment: It reduces risks and maintenance costs, ensuring the continuity and safety of your most critical operations.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed circular stranded copper to IEC 60228 class 2 or class 5.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation screen: Semiconductor material and tinned copper wire braid.
  • Internal coating: Halogen-free compound.
  • Armor: Tinned copper wire braid in accordance with IEC 60092-350 standard.
  • Outer sheath: Halogen-free thermosetting compound, SHF2 (formerly TYPE P6), or mud-resistant halogen-free thermosetting compound, SHF MUD (for the former TYPE P6/P13), in red.
DETAILS

Benefits

  • Fire Safety: Fire-resistant material that ensures continuity of operation.
  • Flame Retardant Properties: It minimizes the spread of fire in case of an accident.
  • Low Smoke Emission and Halogen Free: It increases safety in enclosed environments.
  • Superior Mud Resistance: Special coating to withstand offshore drilling conditions.
  • Wide Temperature Range Operation: Reliable performance from -20°C to +90°C.
  • Robust and Durable Construction: Designed for fixed installations in harsh marine environments.
  • Protection against chemical agents and oils: The outer sheath offers high chemical durability.
  • Compliance with International Standards: Meets stringent NEK 606 and IEC standards.
  • Safe Power Transmission: Efficient shielding to protect against electrical interference.
  • Ideal for Medium Voltage Installations: Designed specifically for 3.6/6kV power systems.

Applications

  • Oil and Gas Platforms: Power supply for exploration and production equipment.
  • Ships and Marine Vessels: Power distribution in onboard systems.
  • Drilling Probes: For fixed installations requiring maximum strength and safety.
  • Floating Production Storage and Offloading (FPSO) Units: Medium voltage power connections in process systems.
  • Power Distribution Systems: Used in main electrical circuits in offshore environments.
  • Power Supply for Critical and Emergency Systems: Ensures functionality during fire situations.
  • Industrial Installations in Harsh Environments: Suitable for locations with mud, oil, and moisture.
  • Port and Maritime Terminals: Power supply for cranes and other machinery.
  • Offshore Renewable Energy: Applications in wind and tidal energy platforms.
  • Shipbuilding Projects: Installation on new vessels and specialized ships.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Fire Resistant Cables for Offshore & Marine Applications (P106 - BFOU/TFOU 3.6/6kV)
ApplicationsFixed installation for medium voltage power. Cables are fire-resistant, flame-retardant, low smoke emission, halogen-free and mud-resistant.
Electrical Parameters
Operating Voltage3.6/6 kV
Maximum DC resistance @20°CRanges from 0.734 Ω/km (25mm²) to 0.0286 Ω/km (630mm²)
DC Capacity @45°C (1 Core)Ranges from 127 A (25mm²) to 890 A (630mm²)
DC Capacity @45°C (3 Cores)Ranges from 89 A (25mm²) to 623 A (630mm²)
Short-Circuit Current (1s)Ranges from 3580 A (25mm²) to 90140 A (630mm²)
Product Design
Conductor MaterialCircular tin-plated braided coil, class 2 or 5 according to IEC 60228.
InsulationMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
Inner Cover (Bedding)Halogen-free compound.
ArmorTinned copper wire mesh.
Outer HemHalogen-free thermoset compound, SHF2, or halogen-free mud-resistant thermoset compound, SHF MUD.
Cover ColorRed.
Product characteristics
Radius of Curvature15 x External Diameter (during installation); 9 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Fire resistantYes (IEC 60331-21).
Flame RetardantYes (IEC 60332-1, IEC 60332-3-22).
Smoke EmissionLow smoke emission (IEC 61034-1,2).
Halogen-freeYes (IEC 60754-1,2).
Mud ResistantYes (NEK 606:2016).
Applicable Standards
IEC 60092-354Electrical design, construction and testing.
IEC 60092-360Insulation and coating compounds.
IEC 60331-21Fire resistance.
IEC 60332-1Flame retardant (single wire).
IEC 60332 3 22Flame retardancy (in beam, Category A).
IEC 60754-1,2Halogen-free gas emission test.
IEC 61034-1,2Smoke density test.
NEK 606:2016Requirements for offshore cables, including resistance to mud.
IEC 60228Drivers.
DIMENSIONAL TABLE
Construction (Number of cores x Cross-sectional area mm²)Nominal Conductor Diameter (mm)Maximum DC Resistance @20°C (Ω/km)Rated Direct Current @45°C 1 Core (A)Rated Direct Current @45°C 3 Cores (A)Short-Circuit Current 1s (A)Operating Voltage (KV)Nominal Insulation Thickness (mm)Nominal Sheath Thickness (mm) - InternalNominal Sheath Thickness (mm) - ExternalNominal Total Diameter (mm)Nominal Weight (kg/km)
1 via
1 x 16N/AN/AN/AN/AN/A3.6/62.51.21.524.8950
1 x 256.57341278935803.6/62.51.21.626.31110
1 x 357.452915711050103.6/62.51.21.627.61260
1 x 508.739119613771503.6/62.51.31.729.11460
1 x 7010.30.27242169100203.6/62.51.71.330.91740
1 x 9512.2195293205135903.6/62.51.41.833.22110
1 x 12013.8154339237171703.6/62.51.91.434.92430
1 x 15015.1126389272214603.6/62.51.41.936.92890
1 x 18517.00.1444311264703.6/62.51.52.039.13370
1 x 24019.6762522365343403.6/62.61.62.142.24100
1 x 30021.9607601421429303.6/62.81.62.244.74810
3 tracks
3 x 16N/AN/AN/A89N/AN/A2.52.31.748.23550
3 x 256.5734N/A11035803.6/62.52.51.851.54180
3 x 357.4529N/A13750103.6/62.52.61.954.74820
3 x 508.7391N/A16971503.6/62.52.71.957.45490
3 x 7010.30.27N/A205100203.6/62.52.82.061.66590
3 x 9512.2195N/A237135903.6/62.53.02.166.27920
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.