DeepSea® Marine Cable NEK 606 P117 TFOU-HCF; 18/30 (36) kV; Medium Voltage Power; Armored; Max. 300,00 mm²; 1 to 03 conductors; Mica + XLPE / LSOH / SHF2 / LSOH HC / SHF1; Fire Resistant; +90°C

DeepSea® Medium Voltage Marine Cable – Fire Resistant SHF2 P117 TFOU-HCF 18/30 (36) kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Medium Voltage Cable Solutions for Critical SafetyDesigned for the most demanding offshore and marine applications. This cable ensures functional integrity, providing essential power and control to keep vital systems operational even during a fire.
  • Extreme Fire Resistance: Operational during hydrocarbon fires at 1100°C, protecting lives and assets.
  • Maximum Human Safety: Low smoke emission and zero halogen to facilitate evacuations and protect equipment.
  • Robust Construction: Tinned copper armor and SHF2 sheaths for maximum durability in harsh environments.
  • Certified Reliability: Compliant with stringent NEK 606 standards and multiple IEC specifications.
  • Essential Applications: Ideal for emergency, power, and lighting systems that simply cannot be interrupted.
PRODUCT DESIGN
  • Conductors: Annealed circular tinned stranded copper to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Tin-plated copper wire mesh.
  • Outer Sheath 1: Halogen-free thermoset compound, SHF2, in red.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Encapamento: Fiberglass tape applied over the existing layers.
  • Outer Sheath 2: Flame-retardant, halogen-free thermoplastic compound, SHF1, in red.
DETAILS

Benefits

  • Extreme Fire Resistance: Operational during hydrocarbon fires at 1100°C.
  • Maximum Security: Halogen-free compound with low emission of smoke and toxic gases.
  • Robust Protection: Tin-plated copper mesh armor for high mechanical strength.
  • Flame Retardant: It minimizes the risk of fire spreading in critical facilities.
  • Superior Reliability: Designed for emergency systems that need to operate under fire.
  • Wide Temperature Range: Safe performance in operating environments from -20°C to +90°C.
  • High Performance Insulation: XLPE insulation to ensure electrical integrity.
  • Double Coating: SHF1 and SHF2 covers for enhanced protection in harsh environments.
  • Quality Conductors: Tin-plated copper that offers excellent conductivity and corrosion resistance.
  • Strict Compliance: Meets international standards IEC and NEK 606 for offshore use.

Applications

  • Oil and Gas Platforms: Power supply and control systems in critical areas.
  • Emergency Lighting Systems: It ensures visibility and safety during evacuations.
  • Ships and Marine Vessels: Power and control circuits in marine environments.
  • Offshore Drilling Rigs: Providing power to essential drilling equipment.
  • Floating Production Storage and Offloading (FPSO) Units: Cabling for production, storage and transfer systems.
  • Emergency Control Circuits: It keeps vital systems operational during a fire.
  • Naval Industry and Shipyards: Used in the construction and maintenance of large vessels.
  • Alarm and Suppression Systems: Reliable power supply for fire detection and suppression systems.
  • Deck Equipment: Connecting machinery exposed to severe weather conditions.
  • Accommodation Modules: Distribution of energy and light in offshore residential areas.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Fire Resistant Cables
CórdobaP117 TFOU-HCF
Electrical Parameters
Operating Voltage8.7/15 kV and 18/30 (36) kV
Maximum DC Resistance @20°C (Ω/km)0.27 (70mm²), 0.195 (95mm²), 0.154 (120mm²), 0.126 (150mm²), 0.1 (185mm²), 0.0762 (240mm²), 0.0607 (300mm²)
Rated Continuous Current @45°C (1 Core)242A (70mm²), 293A (95mm²), 339A (120mm²), 389A (150mm²), 444A (185mm²), 522A (240mm²), 601A (300mm²)
Rated Continuous Current @45°C (3 Cores)169A (50mm²), 205A (70mm²), 237A (95mm²), 272A (120mm²), 311A (150mm²), 365A (185mm²), 421A (240mm²)
Short-Circuit Current (1s)10020A (70mm²), 13590A (95mm²), 17170A (120mm²), 21460A (150mm²), 26470A (185mm²), 34340A (240mm²), 42930A (300mm²)
Product Design
Conductor MaterialCircular tin-plated braided ringed copper, class 2 or 5.
Driver's ScreenSemiconductor material.
InsulationMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
Intermediate Cover (Bedding)Halogen-free compound.
ArmorTinned copper wire mesh.
Fire Protection (HC-fire)Extruded thermoplastic compound for fire protection.
TapeOverlapping fiberglass tape.
Outer Cover 1Halogen-free thermosetting compound, SHF2, red color.
Outer Cover 2Flame-retardant, halogen-free thermoplastic compound, SHF1, red color.
Product characteristics
Application AreaEmergency, control, power, and lighting systems that need to be operational during a hydrocarbon fire at 1100°C.
Minimum Radius of Curvature20 x External Diameter (during installation); 12 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Fire resistantYes.
Flame RetardantYes.
Low Smoke EmissionYes.
Halogen-freeYes.
Ambient Temperature Correction Factors
Rating Factor at 35°C1.1
Rating Factor at 40°C1.05
Rating Factor at 45°C1.0
Rating Factor at 50°C0.94
Rating Factor at 55°C0.88
Rating Factor at 60°C0.82
Rating Factor at 65°C0.74
Rating Factor at 70°C0.67
Rating Factor at 75°C0.58
Rating Factor at 80°C0.47
Applicable Standards
NEK 606:2016IEC 60332-1
IEC 60092-354IEC 60332 3 22
IEC 60092-360IEC 60754-1,2
IEC 60331-21IEC 61034-1,2
IEC 60228 class 2 or 5-
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area (mm²))Nominal Cross-Sectional Area (mm²)Nominal Conductor Diameter (mm)Maximum DC Resistance @20°C (Ω/km)DC Current Capacity @45°C 1 Conductor (A)DC Current Capacity @45°C 3 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (kV)Nominal Insulation Thickness (mm)Nominal Diameter over Cover 1 (mm)Nominal Total Diameter (mm)Nominal Weight (kg/km)
1 x 707010.30.27242169100208.7/1584375.56210
1 x 959512.2195293205135908.7/1584577.56940
1 x 12012013.8154339237171708.715 /84678.57390
1 x 15015015.1126389272214608.7/1584880.57760
1 x 18518517.00.1444311264708.7/15850838405
1 x 24024019.6762522365343408.715 /853869430
1 x 30030021.9607601421429308.715 /8579010540
3 x 50-------88111413255
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.