DeepSea® Marine Cable NEK 606 P120 TFOU; 3.6/6 (7.2) kV; Medium Voltage Power; Armored; Max. 300,00 mm²; 1 to 03 conductors; Mica + XLPE / LSOH / SHF2 / LSOH HC / SHF1; Fire Resistant; +90°C

DeepSea® Medium Voltage Marine Cable – Fire Resistant SHF2 P120 TFOU 3.6/6 (7.2) kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

DeepSea® Medium Voltage Marine Cable for Critical Industrial SafetyDeveloped for applications where failure is not an option. This cable ensures that power and lighting systems remain operational during severe fires, protecting lives and property in offshore and marine environments.
  • Extreme Fire Resistance: It keeps vital systems functioning during hydrocarbon fires at 1100°C.
  • Maximum Human Safety: Low smoke emission and completely halogen-free to protect lives and equipment.
  • Superior Durability: Robust construction with tin-plated copper, ideal for marine and corrosive environments.
  • Wide Operating Range: Reliable and continuous performance in temperatures from -20°C to +90°C.
  • Certified Quality: Full compliance with the stringent international standards NEK 606 and IEC.
PRODUCT DESIGN
  • Conductors: Annealed circular tinned stranded copper to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Tin-plated copper wire mesh.
  • Outer Sheath 1: Halogen-free thermoset compound, SHF2, in red.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Encapamento: Fiberglass tape applied over the existing layers.
  • Outer Sheath 2: Flame-retardant, halogen-free thermoplastic compound, SHF1, in red.
DETAILS

Benefits

  • Fire Safety: Fire resistant, flame retardant and with low smoke emission.
  • Continuous Operation: Designed to function during hydrocarbon fires at 1100°C.
  • Halogen-free: Construction using materials that do not emit toxic gases, increasing safety.
  • Superior Resistance: SHF2 outer coating, a halogen-free thermosetting compound.
  • Reliable Drivers: Tin-plated and annealed copper for maximum conductivity and durability.
  • Electrical Protection: Shielding with tinned copper wire braid for signal integrity.
  • Wide Temperature Range: Operates safely in temperatures from -20°C to +90°C.
  • Installation Flexibility: Optimized bending radius for fixed installations and during passage.
  • International Compliance: It meets stringent standards, including IEC and NEK 606.
  • Robust Construction: Multiple layers of protection, including semiconductor materials and bedding compounds.

Applications

  • Emergency Systems: Ideal for power circuits that need to operate during a fire.
  • Critical Control: Power supply for control and automation systems on offshore platforms.
  • Safety Lighting: Ensures the operation of emergency lighting and evacuation systems.
  • Naval and Maritime Industry: Use on ships, drilling rigs and other offshore installations.
  • Areas with Fire Risk: Perfect for environments where the spread of fire is a concern.
  • Critical Energy Systems: Medium voltage distribution for essential equipment.
  • Aggressive Environments: Resistant to the harsh conditions found at sea and in coastal areas.
  • Essential Infrastructure: Suitable for applications requiring maximum reliability and safety.
  • Power Circuits: Used for main power distribution in marine installations.
  • NEK 606 Projects: For specifications that require high-performance cables and fire protection.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typePower and control cables for offshore and marine applications, fire resistant.
CórdobaP120 TFOU
Electrical Parameters
Operating Voltage3.6/6 (7.2) kV
Maximum DC Resistance @20°CIt varies from 0.0607 to 0.27 Ω/km (depending on the cross-section).
DC Current Capacity @45°C (1 Conductor)It varies from 242 A to 601 A (depending on the cross-section).
DC Current Capacity @45°C (3 Conductors)It varies from 169 A to 421 A (depending on the cross-section).
Short-Circuit Current (1s)It varies from 10020 A to 42930 A (depending on the cross-section).
Product Design
Conductor MaterialTin-plated copper, circular, annealed and strung.
Driver ClassClass 2 or Class 5, according to IEC 60228.
Driver's ScreenSemiconductor material.
InsulationMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
Padding (Inner Cover)Halogen-free compound.
ArmorMesh of tinned copper wires.
External CoverHalogen-free thermosetting compound, SHF2.
Cover ColorRed.
Optional Fire ProtectionExtruded thermoplastic compound for fire protection.
Optional TapeOverlapping fiberglass tape.
Optional CoverageFlame-retardant, halogen-free thermoplastic compound, SHF1, in red.
Product characteristics
Application AreaEmergency control, power, and lighting systems that need to operate during a hydrocarbon fire at 1100°C.
Fire resistantYes.
Flame RetardantYes.
Low Smoke EmissionYes.
Halogen-freeYes.
Minimum Radius of Bend (Installation)20 x Outer Diameter.
Minimum Radius of Curvature (Fixed)12 x Outer Diameter.
Temperature Range-20 ° C to + 90 ° C.
Applicable Standards
NEK 606:2016IEC 60092-354
IEC 60092-360IEC 60331-21
IEC 60332-1IEC 60332 3 22
IEC 60754-1,2IEC 61034-1,2
DIMENSIONAL TABLE

 

Construction: Number of conductors x Cross-sectional area (mm²)Nominal Cross-Sectional Area (mm²)Nominal Conductor Diameter (mm)Maximum DC Resistance @20°C (Ω/km)DC Rating @45°C 1 Conductor (A)DC Rating @45°C 3 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (kV)Nominal Insulation Thickness (mm)Nominal diameter under the reinforcement (mm)Nominal Total Diameter (mm)Nominal Weight (kg/km)
1 x 502.531.8422500
1 x 707010.30.27242169100203.6/62.533.6442830
1 x 959512.20.195293205135903.6/62.535.4463240
1 x 12012013.80.154339237171703.6/62.536.8483550
1 x 15015015.10.126389272214603.6/62.538.2493940
1 x 18518517.00.1444311264703.6/62.540.1514440
1 x 24024019.60.0762522365343403.6/62.542.8545230
1 x 30030021.90.0607601421429303.6/62.546.5586070
3 x 502.558.9726580
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.