DeepSea® Marine Cable NEK 606 P122 TFOU; 8.7/15 (12) kV; Medium Voltage Power; Armored; Max. 300,00 mm²; 1 to 03 conductors; Mica + XLPE / LSOH / SHF2 / LSOH HC / SHF1; Fire Resistant; +90°C

DeepSea® Medium Voltage Marine Cable – Fire Resistant SHF2 P122 TFOU 8.7/15 (12) kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Medium Voltage Marine Cable: Critical Safety GuaranteedDesigned for the most critical operations in offshore and maritime environments. Ensures maximum power and protection under intense fire, keeping emergency, control, and lighting systems always operational.
  • Extreme Fire Resistance: Operational during fires of 1100°C, essential for emergency systems.
  • Human and Environmental Protection: Halogen-free, with low emission of smoke and toxic gases.
  • Robust Offshore Construction: Armor with copper braid for maximum mechanical and thermal durability.
  • High Operational Reliability: Superior performance in extreme temperatures, from -20°C to +90°C.
  • NEK 606 Quality Standard: Certified for the most demanding naval and offshore applications, guaranteeing performance.
PRODUCT DESIGN
  • Conductors: Annealed circular tinned stranded copper to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Tin-plated copper wire mesh.
  • Outer Sheath 1: Halogen-free thermoset compound, SHF2, in red.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Encapamento: Fiberglass tape applied over the existing layers.
  • Outer Sheath 2: Flame-retardant, halogen-free thermoplastic compound, SHF1, in red.
DETAILS

Benefits

  • Maximum Fire Safety: Fire resistant, flame retardant, low smoke emission and halogen-free.
  • Critical Operation Guaranteed: It keeps emergency systems functioning during hydrocarbon fires at 1100°C.
  • High Durability: Tin-plated copper mesh armor for mechanical protection and robust shielding.
  • Environmental and Human Protection: This halogen-free compound does not emit toxic gases in case of fire.
  • Wide Temperature Range: Designed to operate safely in conditions ranging from -20°C to +90°C.
  • Superior Electrical Insulation: XLPE insulation that guarantees excellent performance in marine environments.
  • Compliance with Standards: Meets stringent international standards IEC and NEK 606 for offshore applications.
  • Reliable Conductivity: Tinned copper conductors that offer excellent performance and corrosion resistance.
  • Robust Coating: Outer covering made of SHF2, a thermosetting compound resistant to the marine environment.
  • Secure Installation: Construction that guarantees circuit integrity even under extreme fire conditions.

Applications

  • Oil and Gas Platforms: Power supply and control for drilling and production systems.
  • Ships and Vessels: Wiring in cargo ships, passenger ships, drilling rigs and floating production, storage and offloading (FPSO) units.
  • Emergency Systems: Essential circuits for fire alarm, escape lighting and communication.
  • Control and Lighting: Power distribution for critical systems that cannot fail during a fire.
  • Petrochemical Industry: Installations in refineries and plants with a high risk of hydrocarbon fires.
  • Offshore Drilling Units: Cabling for offshore exploration and production equipment.
  • Accommodation Modules: To ensure safety in common areas on platforms and vessels.
  • Medium Voltage Distribution: Power supply for electrical panels and equipment in marine and industrial environments.
  • Critical Security Systems: Power for fire water pumps and emergency ventilation systems.
  • Port Infrastructure: Applications in cranes and other handling equipment in ports and terminals.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Fire Resistant Cables for Offshore and Marine Applications (P122 TFOU-FIRE RESISTANT).
ApplicationUsed for emergency control, power, and lighting systems that need to be operational during a hydrocarbon fire at 1100°C.
Electrical Parameters
Operating Voltage6/10 kV or 8.7/15 (12) kV
Maximum DC Resistance @20°CIt varies from 0.0607 to 0.27 Ω/km depending on the cross-sectional area of ​​the conductor.
DC Capacity @45°C (1 line)It varies from 242 A to 601 A depending on the cross-sectional area of ​​the conductor.
DC Capacity @45°C (3-way)It varies from 169 A to 421 A depending on the cross-sectional area of ​​the conductor.
Short-Circuit Current (1s)It varies from 10020 A to 42930 A depending on the cross-sectional area of ​​the conductor.
Product Design
Conductor MaterialAnnealed tin-plated copper, class 2 or class 5 according to IEC 60228.
Driver DesignCircular braid.
Driver's ScreenSemiconductor material.
InsulationMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
Inner LayerHalogen-free compound.
ArmorMesh of tinned copper wires.
External CoverHalogen-free thermosetting compound, SHF2, red color.
Optional Fire ProtectionExtruded thermoplastic compound for fire protection.
Optional TapeOverlapping fiberglass tape.
Optional CoverageFlame-retardant, halogen-free thermoplastic compound, SHF1, red color.
Cable FormatRound
Product characteristics
Minimum Radius of Curvature20 x External Diameter (during installation); 12 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Fire resistantYes.
Flame RetardantYes.
Low Smoke EmissionYes.
Halogen-freeYes.
Ambient Temperature Correction Factors
35°C1.10
40°C1.05
45°C1.00
50°C0.94
55°C0.88
60°C0.82
65°C0.74
70°C0.67
75°C0.58
80°C0.47
Applicable Standards
NEK 606:2016IEC 60092-354
IEC 60092-360IEC 60331-21
IEC 60332-1IEC 60332 3 22
IEC 60754-1,2IEC 61034-1,2
IEC 60228-

Table of Ambient Temperature Correction Factors

Ambient Temperature (°C)35404550556065707580
Classification Factor1.101.051.00.940.880.820.740.670.580.47
DIMENSIONAL TABLE
Construction (Number of Roads x Cross-Section (mm²))Nominal Cross-Sectional Area (mm²)Nominal Conductor Diameter (mm)Maximum DC Resistance at 20°C (Ω/km)DC Capacity at 45°C 1 Channel (A)DC Capacity at 45°C 3-Way (A)Short-Circuit Current 1s (A)Operating Voltage (KV)Nominal Insulation Thickness (mm)Nominal Diameter under the Reinforcement (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1 x 5050------4.535.9472930
1 x 707010.30.27242-100206/104.537.6483260
1 x 959512.2195293-135906/104.539.4503690
1 x 12012013.8154339-171706/104.540.8524040
1 x 15015015.1126389-214606/104.542.2534400
1 x 18518517.00.1444-264706/104.544.1554950
1 x 24024019.6762522-343406/104.546.6585700
1 x 30030021.9607601-429306/104.549.9616530
3 x 5050---169*--4.567.5817940
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.