DeepSea® Marine Cable NEK 606 P123 TFOU; 12/20 (24) kV; Medium Voltage Power; Armored; Max. 300,00 mm²; 1 to 03 conductors; Mica + XLPE / LSOH / SHF2 / LSOH HC / SHF1; Fire Resistant; +90°C

DeepSea® Medium Voltage Marine Cable – Fire Resistant SHF2 P123 TFOU 12/20 (24) kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Offshore and Marine Cables NEK606 Fire ResistantDesigned for the most critical applications in offshore and marine environments. This medium voltage cable ensures power continuity in emergency systems, even during a hydrocarbon fire at 1100°C.
  • Unparalleled Security: Fire resistant (1100°C), low smoke and halogen-free to protect lives and assets.
  • Certified Reliability: Designed and built in accordance with the stringent international standards IEC and NEK 606.
  • Robust Construction: Braided copper conductors, shielding and armor with braided copper wires for maximum durability.
  • Critical Applications: Ideal for emergency, control and lighting systems.
  • Superior Performance: High current capacity and wide operating temperature range (-20°C to +90°C) for any scenario.
PRODUCT DESIGN
  • Conductors: Annealed circular tinned stranded copper to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Tin-plated copper wire mesh.
  • Outer Sheath 1: Halogen-free thermoset compound, SHF2, in red.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Encapamento: Fiberglass tape applied over the existing layers.
  • Outer Sheath 2: Flame-retardant, halogen-free thermoplastic compound, SHF1, in red.
DETAILS

Benefits

  • Fire Safety: Fire-resistant, flame-retardant, with low smoke emission and halogen-free.
  • Critical Operation Guaranteed: Designed to keep emergency systems operational even during a hydrocarbon fire at 1100°C.
  • High Reliability: Tinned copper conductors that offer excellent conductivity and corrosion resistance.
  • Superior Insulation: XLPE insulation and semiconductor materials ensure signal integrity and electrical safety.
  • Robust Protection: Shielding with braided copper wires and SHF2 outer coating for maximum mechanical protection and durability.
  • Halogen-free: Construction using materials that do not emit toxic gases, increasing safety for people and equipment.
  • Thermal Resistance: It operates reliably over a wide temperature range, from -20°C to +90°C.
  • Installation Flexibility: Designed for fixed installations in demanding environments, ensuring a long service life.
  • International Standards: Manufactured in accordance with the stringent NEK 606 and IEC standards.
  • Voltage Versatility: Suitable for medium voltage systems, with an operating voltage of 12/20 (24) kV.

Applications

  • Offshore Platforms: Power supply, control and lighting systems in oil and gas installations.
  • Ships and Vessels: Used in critical systems on passenger ships, cargo ships and special vessels.
  • Emergency Systems: Ideal for safety circuits that need to function during a fire, such as alarms and emergency lighting.
  • Maritime Units: Application in floating production, storage and offloading (FPSO) units and other offshore structures.
  • Naval Industry: Installation in shipyards and in the construction of vessels that require high-performance and safe cables.
  • Critical Control Panels: Power supply for panels and control systems that cannot fail in emergency situations.
  • Security Lighting Systems: Ensures that escape routes and essential areas remain illuminated during a fire.
  • Essential Power Circuits: Providing power to vital equipment in offshore and marine environments.
  • Refineries and Petrochemical Plants: Use in areas where resistance to hydrocarbons and fire is essential for safety.
  • Maritime Engineering Projects: A robust solution for customized projects that demand maximum safety and reliability at sea.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeP123 TFOU-FIRE RESISTANT 12/20 (24) kV
ApplicationsFire-resistant, flame-retardant, low-smoke, and halogen-free cables used for emergency control, power, and lighting systems that need to be operational during a hydrocarbon fire at 1100°C.
Electrical Parameters
Operating Voltage12/20 (24) kV
Maximum DC resistance at 20°CRanges from 0.0607 Ω/km (300mm²) to 0.27 Ω/km (70mm²)
DC Capacity @45°C (1 core)Ranges from 242 A (70mm²) to 601 A (300mm²)
DC Capacity @45°C (3 cores)Ranges from 169 A (70mm²) to 421 A (300mm²)
Short-Circuit Current (1s)Ranges from 10020 A (70mm²) to 42930 A (300mm²)
Product Design
Conductor MaterialCircular tin-plated braided ringed copper, class 2 or 5.
Driver's ScreenSemiconductor material.
InsulationMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
Interior BeddingHalogen-free compound.
ArmorMesh of tinned copper wires.
External CoverHalogen-free thermosetting compound, SHF2, red color.
Optional Fire ProtectionExtruded thermoplastic compound for fire protection.
Optional TapeOverlapping fiberglass tape.
Optional CoverageFlame-retardant, halogen-free thermoplastic compound, SHF1, red color.
Mechanical and Thermal Properties
Radius of Curvature20 x External Diameter (during installation); 12 x External Diameter (fixed installation)
Temperature Range-20 ° C to + 90 ° C
Applicable Standards
NEK 606:2016IEC 60092-354
IEC 60092-360IEC 60331-21
IEC 60332-1IEC 60332 3 22
IEC 60754-1,2IEC 61034-1,2
IEC 60228

Table of Ambient Temperature Correction Factors

Ambient Temperature (°C)35404550556065707580
Classification Factor1.101.051.00.940.880.820.740.670.580.47
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area mm2)Nominal Conductor Diameter (mm)Maximum DC Resistance @ 20C (Ohm/km)Direct Current @45C 1 Conductor (A)Direct Current @45C 3 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (kV)Nominal Insulation Thickness (mm)Nominal Diameter under the Reinforcement (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1 x 50------------------5.537.9493160
1 x 7010.30.27242---1002012/205.539.6513500
1 x 9512.2195293---1359012/205.541.4533940
1 x 12013.8154339---1717012/205.542.8544290
1 x 15015.1126389---2146012/205.544.2566470
1 x 18517.00.1444---2647012/205.546.1585210
1 x 24019.6762522---3434012/205.548.6605980
1 x 30021.9607601---4293012/205.551.9646840
3 x 50------------------5.571.9868600
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.