DeepSea® Marine Cable NEK 606 P124 TFOU; 18/30 (36) kV; Medium Voltage Power; Armored; Max. 300,00 mm²; 1 to 03 conductors; Mica + XLPE / LSOH / SHF2 / LSOH HC / SHF1; Fire Resistant; +90°C

DeepSea® Medium Voltage Marine Cable – Fire Resistant SHF2 P124 TFOU 18/30 (36) kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Medium Voltage Fire Resistant Cable for Critical SafetyDesigned to operate in extreme conditions, this cable ensures that emergency, control, and lighting systems remain functional even during a hydrocarbon fire at 1100°C.
  • Superior Security: Halogen-free and low-smoke, it protects lives and equipment in case of fire.
  • Performance Under Fire: Maintains power in critical systems during hydrocarbon fires at 1100°C.
  • Robust Construction: Tinned copper conductors and reinforced shielding for maximum durability and reliability.
  • Offshore and Maritime Application: SHF2 coating for maximum protection in harsh and corrosive environments.
  • Certified Quality: It meets the stringent NEK 606 and IEC standards, ensuring superior performance and total reliability.
PRODUCT DESIGN
  • Conductors: Annealed circular tinned stranded copper to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Tin-plated copper wire mesh.
  • Outer Sheath 1: Halogen-free thermoset compound, SHF2, in red.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Encapamento: Fiberglass tape applied over the existing layers.
  • Outer Sheath 2: Flame-retardant, halogen-free thermoplastic compound, SHF1, in red.
DETAILS

Benefits

  • Maximum Fire Safety: Fire resistant, while maintaining the operation of critical systems.
  • Human and Environmental Protection: Halogen-free, with low emission of smoke and toxic gases.
  • Operation in Extreme Conditions: Designed to function during hydrocarbon fires at 1100°C.
  • Robust Construction: Copper mesh shielding that offers mechanical protection and protection against interference.
  • High Durability: SHF2 exterior coating ideal for harsh marine and offshore environments.
  • Easy Installation: Flexibility that allows for optimized bending radii in confined spaces.
  • Reliable Electrical Performance: High current carrying capacity and short-circuit resistance.
  • Limited Fire Spread: Flame-retardant material that enhances the safety of the installation.
  • Wide Temperature Range: Ensures stable operation in temperatures ranging from -20°C to +90°C.
  • Compliance with Standards: Meets stringent international standards IEC and NEK 606.

Applications

  • Oil and Gas Platforms: Power supply for control systems, energy, and emergency lighting.
  • Ships and Vessels: Power and control circuits in areas critical to onboard safety.
  • Floating Production Storage and Offloading (FPSO) Units: Electrical installations requiring maximum fire protection.
  • Alarm and Fire Systems: Ensures continuous operation during a fire situation.
  • Petrochemical Industry: Applications in areas with a high risk of hydrocarbon fires.
  • Emergency Lighting: Keep escape routes and safe areas illuminated under intense fire.
  • Offshore Drilling Equipment: Medium voltage connections for machinery in harsh environments.
  • Critical Control Panels: Reliable power supply for essential systems that cannot fail.
  • Firefighting Pumps: It provides power to essential fire suppression equipment.
  • Terminals and Port Facilities: Power circuits in areas subject to harsh marine environments.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Fire Resistant Power Cables for Offshore & Marine Use (P124 TFOU-FIRE RESISTANT)
ApplicationsUsed for emergency control, power, and lighting systems that need to be operational during a hydrocarbon fire at 1100°C.
Electrical Parameters
Operating Voltage12/20 (24) kV or 18/30 (36) kV
Maximum DC resistance at 20°CRanges from 0.0607 Ω/km (300mm²) to 0.27 Ω/km (70mm²)
DC Capacity at 45°C (1 Core)Ranges from 242 A (70mm²) to 601 A (300mm²)
DC Capacity at 45°C (3 Cores)Ranges from 169 A (70mm²) to 421 A (300mm²)
Short-Circuit Current (1s)Ranges from 10020 A (70mm²) to 42930 A (300mm²)
Product Design
Conductor MaterialCircular annealed braided tin-plated copper
Driver ClassClass 2 or Class 5 according to IEC 60228
Driver's ScreenSemiconductor material
Insulation MaterialMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire braid
Inner Cover (Bedding)Halogen-free compound
ArmorTinned copper wire braid
Outer CoverHalogen-free thermosetting compound, SHF2, red color.
Optional Fire ProtectionExtruded thermoplastic compound for fire protection.
Optional TapeOverlapping fiberglass tape
Optional CoverFlame-retardant, halogen-free thermoplastic compound, SHF1, red color.
Product characteristics
Fire resistantYes, according to IEC 60331-21
Flame RetardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22
Low Smoke EmissionYes, according to IEC 61034-1,2
Halogen-freeYes, according to IEC 60754-1,2
Minimum Radius of Curvature20 x External Diameter (during installation); 12 x External Diameter (fixed installation)
Temperature Range-20 ° C to + 90 ° C
Applicable Standards
NEK 606:2016IEC 60092-354
IEC 60092-360IEC 60228
IEC 60331-21IEC 60332-1
IEC 60332 3 22IEC 60754-1,2
IEC 61034-1,2-

Ambient Temperature Correction Factors

Ambient Temperature (°C)35404550556065707580
Classification Factor1.101.051.00.940.880.820.740.670.580.47
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-section mm²)Nominal Cross-Sectional Area (mm²)Nominal Conductor Diameter (mm)Maximum DC Resistance @ 20°C (Ω/km)DC Current Capacity @45°C 1 Conductor (A)DC Current Capacity @45°C 3 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (kV)Nominal Insulation Thickness (mm)Nominal Diameter under the Reinforcement (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1 × 508.04375.56210
1 × 707010.30.272421691002012/208.04577.56940
1 × 959512.21952932051359012/208.04678.57390
1 × 12012013.81543392371717012/208.04880.57760
1 × 15015015.11263892722146012/208.050838405
1 × 18518517.00.14443112647012/208.053869430
1 × 24024019.67625223653434012/208.0579010540
1 × 30030021.96076014214293012/208.08111413255
3 × 508.08912316520
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.