DeepSea® Marine Cable NEK 606 P102 (P2 or P2/P9) TFOU; 3.6/6KV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 03 conductors; XLPE / LSOH / SHF2 – SHF2 MUD; Flame Retardant; +90°C

DeepSea® Medium Voltage Marine Cable – Flame Retardant SHF2 P102 (P2 or P2/P9) TFOU 3.6/6KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK606 DeepSea® Marine Cable: Power and Safety in Extreme EnvironmentsDesigned for the most demanding offshore conditions, this cable is flame-retardant and halogen-free. It offers maximum protection for life and property, ensuring continuous power for your critical installations.
  • Maximum Security Priority: Halogen-free compound, with low smoke and flame resistance.
  • Stable Energy and Power: Ensures reliable medium-voltage transmission for uninterrupted operation.
  • Robust and Durable: Shielding with braided copper wire and mud-resistant coating.
  • Extreme Environmental Resistance: It withstands mud, oils, and harsh weather.
  • Extended Useful Life: High-quality materials that ensure durability, reducing replacement and maintenance costs.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed circular stranded copper according to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Mesh of tinned copper wires according to IEC 60092-350.
  • External Coating: Halogen-free thermoset compound, SHF2 (for the former TYPE P2), or halogen-free mud-resistant thermoset compound, SHF MUD (for the former TYPE P2/P9), in red.
DETAILS

Benefits

  • Enhanced Security: The cables are flame retardant, with low smoke emission and halogen-free, minimizing risks in case of fire.
  • High Environmental Resistance: Mud-resistant (MUD) exterior compound, ideal for fixed installations in harsh offshore and marine environments.
  • Robust Construction: Tinned and braided copper conductors that offer excellent durability and electrical conductivity.
  • Superior Electrical Protection: Shielding with semiconductor tape and tinned copper wire braid to ensure the integrity of the medium voltage signal.
  • Wide Temperature Range: Designed to operate safely in a temperature range of -20°C to +90°C, adapting to various climatic conditions.
  • Quality Insulation: Halogen-free XLPE insulation ensures stable and reliable electrical performance.
  • Compliance with Standards: Manufactured in accordance with stringent international standards such as NEK 606 and IEC, ensuring high quality.
  • Versatile Installation: It allows a bending radius of 15 times the outside diameter during installation and 9 times after fixed installation.
  • Durability and Reliability: Designed for long-term fixed installations, reducing the need for maintenance and replacement.
  • Operational Safety: Operating voltage of 3.6/6KV, suitable for medium voltage power distribution systems.

Applications

  • Offshore Platforms: Medium voltage power supply systems in oil and gas installations.
  • Naval Industry: Used on ships and other maritime vessels for the distribution of electrical power.
  • Drilling Systems: Applications in drilling equipment that require cables resistant to mud and harsh conditions.
  • Floating Production Storage and Offloading (FPSO) Units: Ideal for fixed electrical installations in production, storage and transfer units.
  • Maritime Terminals: Power supply for equipment and infrastructure in ports and terminals.
  • Offshore Renewable Energy Projects: Used in wind farms and other offshore renewable energy installations.
  • Mobile Substations: Power connection in temporary or mobile substations in marine environments.
  • Offshore Support Vessels: Power supply for cranes, thrusters and other onboard systems.
  • Coastal Industrial Applications: Employed in refineries and industrial plants located in coastal areas.
  • General Power Distribution: For any fixed installation that requires a robust and safe medium voltage cable.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Cables for Offshore & Marine Applications (P102, TFOU).
ApplicationsFixed installation for medium voltage power. They are flame retardant, low smoke emission, halogen-free and mud resistant.
Electrical Parameters
Operating Voltage3.6 / 6 kV
Maximum DC Resistance of the Conductor at 20°CIt varies from 1.16 Ω/km (for 16mm²) to 0.0286 Ω/km (for 630mm²).
DC Capacity at 45°C (1 core)It ranges from 96 A (for 16 mm²) to 890 A (for 630 mm²).
DC Capacity at 45°C (3 cores)It ranges from 67 A (for 16 mm²) to 623 A (for 300 mm²).
Short-Circuit Current (1s)It ranges from 2290 A (for 16 mm²) to 90140 A (for 630 mm²).
Product Design
Conductor MaterialCircular tin-plated braided ringed copper, class 2 or 5.
Driver's ScreenSemiconductor material.
Insulation MaterialHalogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU
Isolation ScreenSemiconductor material and tinned copper wire braid.
Inner Cover (Bedding)Halogen-free compound.
ArmorBraided tinned copper wire.
Exterior Roofing MaterialHalogen-free thermoset compound, SHF2, or halogen-free mud-resistant thermoset compound, SHF MUD.
Cover ColorRed.
Product characteristics
Minimum Radius of Curvature15 x External Diameter (during installation); 9 x External Diameter (after fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Maximum Temperature in the Conductor+90°C.
Ambient Temperature Correction FactorsFactor of 1.1 at 35°C down to 0.47 at 80°C.
Flame retardantYes.
Halogen-freeYes.
Low smoke emissionYes.
Mud resistantYes.
Dimensions and Weight (Examples)
Construction 1x16mm²External Diameter: 22.8 mm, Weight: 780 kg/km
Construction 3x16mm²External Diameter: 44.9 mm, Weight: 2930 kg/km
Construction 1x300mm²External Diameter: 42.3 mm, Weight: 4625 kg/km
Construction 3x300mm²External Diameter: 89.3 mm, Weight: 12940 kg/km
Construction 1x630mm²External Diameter: 55.1 mm, Weight: 8170 kg/km
Applicable Standards
IEC 60092-354IEC 60332 3 22
IEC 60092-360IEC 60754-1,2
IEC 60332-1IEC 61034-1,2
IEC 60228NEK 606:2016
DIMENSIONAL TABLE
Construction (Roads x Section)Nominal Cross-Sectional Area (mm²)Nominal Conductor Diameter (mm)Nominal Insulation Thickness (mm)Nominal Thickness of Internal Cover (mm)Nominal Thickness of the External Cover (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Maximum DC Resistance @20°C (Ω/km)Direct Current @45°C (A)Short-Circuit Current 1s (A)Operating Voltage (kV)
1 via
1 x 16165.12.51.41.122.87801.169622903.6/6
1 x 25256.52.51.51.124.0102073412735803.6/6
1 x 35357.42.51.51.225.1115552915750103.6/6
1 x 50508.72.51.61.226.3132039119671503.6/6
1 x 707010.32.51.61.328.215950.27242100203.6/6
1 x 959512.22.51.31.730.01905195293135903.6/6
1 x 12012013.82.51.81.431.82235154339171703.6/6
1 x 15015015.12.51.81.433.52550126389214603.6/6
1 x 18518517.02.51.91.535.430150.1444264703.6/6
1 x 24024019.62.62.01.538.83725762522343403.6/6
1 x 30030021.92.81.62.142.34625607601429303.6/6
3 tracks
3 x 16165.12.51.62.244.929301.166722903.6/6
3 x 25256.52.51.72.345.433907348935803.6/6
3 x 35357.42.51.82.447.6382052911050103.6/6
3 x 50508.72.51.92.550.9449539113771503.6/6
3 x 707010.32.52.72.054.855850.27169100203.6/6
3 x 959512.22.52.12.858.96765195205135903.6/6
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.