DeepSea® Marine Cable NEK 606 P103 (P3 or P3/P10) TFOU; 6/10KV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 03 conductors; XLPE / LSOH / SHF2 – SHF2 MUD; Flame Retardant; +90°C

DeepSea® Medium Voltage Marine Cable – Flame Retardant SHF2 P103 (P3 or P3/P10) TFOU 6/10KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

DeepSea® Power and Safety in Medium Voltage for Marine EnvironmentsDesigned for the most extreme offshore conditions, this medium voltage cable guarantees performance and safety. Its robust construction with state-of-the-art materials ensures the integrity of your operation, maximizing energy efficiency in fixed installations.
  • Maximum Safety Onboard: Halogen-free, low-smoke, and flame-retardant for the protection of lives and equipment.
  • Extreme Resistance: SHF MUD cover resistant to drilling mud and the most aggressive marine environments.
  • Reliable Performance: Stable operation from -20°C to +90°C, ensuring continuous and reliable power supply.
  • Certified Quality: Fully compliant with the stringent international standards NEK 606 and IEC for offshore applications.
  • Versatile Installation: Ideal for fixed power installations on platforms, ships and other offshore maritime units.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed circular stranded copper according to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU
  • Insulation screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Mesh of tinned copper wires according to IEC 60092-350.
  • External Coating: Halogen-free thermoset compound, SHF2 (for the former TYPE P3), or halogen-free mud-resistant thermoset compound, SHF MUD (for the former TYPE P3/P10), in red.
DETAILS

Benefits

  • Enhanced fire safety: Construction using halogen-free, low-smoke, and flame-retardant materials.
  • Superior resistance to mud: SHF MUD outer coating designed to withstand offshore drilling environments.
  • High corrosion resistance: Conductors and shielding made of tinned copper, ideal for saline and humid atmospheres.
  • Robust mechanical protection: Copper wire mesh armor that protects against impacts and crushing.
  • Operation in extreme temperatures: Operating temperature range from -20°C to +90°C, ensuring performance in diverse climates.
  • Reliable power transmission: Semiconductor screens and shielding ensure the integrity of the medium voltage signal.
  • Safety for people and equipment: Halogen-free materials do not emit toxic or corrosive gases in the event of a fire.
  • Long service life in harsh environments: SHF2 thermoset compound ensures durability against weathering and chemical agents.
  • Compliance with strict standards: Meets NEK 606 standards and various IEC standards for marine and offshore cables.
  • Ease of installation: Designed for fixed installation, with bending radii optimized for confined spaces on vessels.

Applications

  • Oil and gas platforms: Medium voltage power supply systems in fixed and floating installations.
  • Drillships: Power distribution for drilling equipment, thrusters and auxiliary systems.
  • Floating Production Storage and Offloading (FPSO) units: Interconnection of energy generation, processing, and storage modules.
  • Offshore support vessels (PSVs): Power supply for deck systems, winches and pumps.
  • Shipyards and port areas: Power circuits for cranes, gantries and other large machines.
  • Propulsion and maneuvering systems: Power supply for medium-voltage electric motors in large vessels.
  • Drillships and construction vessels: Power distribution for specialized underwater research and construction equipment.
  • Maritime terminals: Power grids for loading and unloading operations in exposed environments.
  • Offshore modules and accommodations: Main power wiring in areas requiring maximum fire safety.
  • Offshore renewable energy projects: Connecting equipment to wind or tidal energy platforms.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Offshore & Marine Cables, model P103 (TFOU), for fixed installation.
ApplicationsUsed for fixed medium-voltage power installations, they are mud-resistant, flame-retardant, have low smoke emission, and are halogen-free.
Electrical Parameters
Operating Voltage6/10 KV
DC Capacity @ 45°C (1 core)It varies from 96 A to 890 A, depending on the cross-sectional area of ​​the conductor.
DC Capacity @ 45°C (3 cores)It varies from 67 A to 623 A, depending on the cross-sectional area of ​​the conductor.
Short-Circuit Current (1s)It varies from 2290 A to 90140 A, depending on the cross-sectional area of ​​the conductor.
Maximum DC Resistance @ 20°CIt varies from 1.16 Ω/km to 0.0286 Ω/km, depending on the cross-sectional area of ​​the conductor.
Product Design
Conductor MaterialCircular braided copper, ringed and tinned, according to IEC 60228 class 2 or 5.
Driver's ScreenSemiconductor material.
InsulationHalogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU
Isolation ScreenSemiconductor material and tinned copper wire braid.
BedHalogen-free compound.
ArmorTinned copper wire braid, conforming to IEC 60092-350.
Outer Cover (Hem)Halogen-free thermosetting compound (SHF2) or halogen-free mud-resistant thermosetting compound (SHF MUD).
Cover ColorRed.
Cross-sectional AreaAvailable in sizes from 16 mm² to 630 mm².
Mechanical and Thermal Characteristics
Minimum Radius of Curvature15 × External Diameter (during installation); 9 × External Diameter (after fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Nominal Outside DiameterIt varies from 24,0 mm to 85,0 mm, depending on the construction (number of cores and cross-section).
Nominal WeightIt varies from 900 kg/km to 16300 kg/km, depending on the construction.
Fire and Environmental Properties
Flame retardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1,2.
Low Smoke EmissionYes, in accordance with IEC 61034-1,2.
Mud ResistantYes.
Ambient Temperature Correction Factors
Classification Factor35°C: 1.1; 40°C: 1.05; 45°C: 1.0; 50°C: 0.94; 55°C: 0.88; 60°C: 0.82; 65°C: 0.74; 70°C: 0.67; 75°C: 0.58; 80°C: 0.47
Applicable Standards
IEC 60092-354IEC 60092-360
IEC 60332-1IEC 60332 3 22
IEC 60754-1,2IEC 61034-1,2
NEK 606:2016IEC 60228
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area in mm²)Nominal Conductor Diameter (mm)Nominal Insulation Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Total Diameter (mm)Nominal Weight (kg/km)Maximum DC Resistance @20°C (Ω/km)DC Current Capacity @45°C 1 Conductor (A)DC Current Capacity @45°C 3 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (KV)
1 x 165.23.41.11.524.09001.16966722906/10
1 x 256.53.41.51.226.011407341278935806/10
1 x 357.43.41.21.626.9126552915711050106/10
1 x 508.73.41.61.228.3146039119613771506/10
1 x 7010.33.41.31.730.017100.27242169100206/10
1 x 9512.23.41.31.832.02060195293205135906/10
1 x 12013.83.41.81.433.82380154339237171706/10
1 x 15015.13.41.91.435.32700126389272214606/10
1 x 18517.03.42.01.537.832250.1444311264706/10
1 x 24019.63.41.62.141.03990762522365343406/10
1 x 30021.93.42.21.643.74760607601421429306/10
3 x 165.23.42.31.746.033001.16966722906/10
3 x 256.53.42.41.850.139057341278935806/10
3 x 357.43.42.51.852.2436052915711050106/10
3 x 508.73.41.92.655.1518539119613771506/10
3 x 7010.33.42.02.758.961250.27242169100206/10
3 x 9512.23.42.92.163.57500195293205135906/10
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.