DeepSea® Marine Cable NEK 606 P104 (P4 or P4/P11) TFOU; 8.7/15KV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 03 conductors; XLPE / LSOH / SHF2 – SHF2 MUD; Flame Retardant; +90°C

DeepSea® Medium Voltage Marine Cable – Flame Retardant SHF2 P104 (P4 or P4/P11) TFOU 8.7/15KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK 606 DeepSea® Offshore Cable: Safety and Performance in Medium VoltageDesigned for the most extreme conditions in marine and offshore environments. Ensures unparalleled safety and long-lasting performance, protecting critical operations and equipment in medium-voltage installations. It's the ultimate choice.
  • Maximum Safety Onboard: Flame retardant, low smoke and halogen-free for the protection of lives and assets.
  • Superior Resistance: Resistant to drilling mud (MUD), oils, and various chemicals.
  • Reliable Performance: Stable and efficient power transmission, even at temperatures from -20°C to +90°C.
  • Global Certification: It meets the stringent NEK 606 and IEC standards, guaranteeing full compliance and quality.
  • Specific Application: Ideal for power systems on platforms, ships and other marine units.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed circular stranded copper according to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU
  • Insulation screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Mesh of tinned copper wires according to IEC 60092-350.
  • External Coating: Halogen-free thermoset compound, SHF2 (for the former TYPE P4), or halogen-free mud-resistant thermoset compound, SHF MUD (for the former TYPE P4/P11), in red.
DETAILS

Benefits

  • Maximum Security: Halogen-free construction, with low smoke emission and flame-retardant properties.
  • Superior Resistance: Robust casing (SHF MUD) that offers superior protection against mud and drilling fluids.
  • Mechanical Protection: Armor with braided copper wires that ensures high durability against impacts and crushing.
  • Wide Temperature Range: Stable and reliable operation in extreme conditions, ranging from -20°C to +90°C.
  • Strict Compliance: Designed to meet the stringent international standards NEK 606 and IEC for offshore use.
  • Optimized Conductivity: Tinned copper conductors that ensure excellent electrical performance and corrosion resistance.
  • Reliable Isolation: XLPE insulation ensures signal integrity and increases operational safety.
  • Robust Coating: Thermosetting compound (SHF2) that resists oils, chemicals and UV exposure.
  • Easy Installation: Flexibility and optimized bending radius allow for efficient assembly in complex spaces.
  • Marine Durability: Designed to withstand the harshest conditions, including vibration, humidity, and salt spray.

Applications

  • Oil and Gas Platforms: Power supply for drilling systems, production, and critical offshore equipment.
  • Ships and Vessels: Medium voltage power distribution for propulsion systems, cranes and onboard services.
  • FPSO Units: Ideal for fixed installations in floating production, storage and transfer units.
  • Energy Systems: Used in main power distribution networks in maritime and industrial complexes.
  • Drilling Areas: Perfect for locations with direct exposure to drilling mud and other harsh chemicals.
  • Port Terminals: Feeding containers, gantries and other heavy handling equipment.
  • Offshore Wind Energy: Electrical connection of wind turbines and substations in offshore wind farms.
  • Production Modules: Providing power to essential equipment installed on the decks of platforms.
  • Naval Industry: Applications in shipyards during the construction and modernization of ships and offshore structures.
  • Generator Rooms: Secure connection between power generators and main electrical distribution panels.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Cables for Offshore and Marine Applications (P104 / TFOU 8.7/15KV).
ApplicationsFixed installation for medium voltage power. They are flame retardant, with low smoke emission, halogen-free and resistant to mud.
Electrical Parameters
Operating Voltage8.7/15KV
Maximum DC Resistance of the Conductor at 20°CIt varies from 0.0286 Ω/km (630mm²) to 0.734 Ω/km (for smaller sections not specified in the document).
DC Capacity @45°C (1 core)It ranges from 127 A (for smaller sections) to 890 A (630 mm²).
DC Capacity @45°C (3 cores)It ranges from 89 A (for smaller sections) to 623 A (630 mm²).
Short-Circuit Current (1s)It ranges from 3580 A (for smaller sections) to 90140 A (630 mm²).
Product Design
Conductor MaterialCircular tin-plated braided wire, class 2 or 5 according to IEC 60228.
Driver's ScreenSemiconductor material.
InsulationHalogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU
Isolation ScreenSemiconductor material and tinned copper wire mesh.
Intermediate Cover (Bedding)Halogen-free compound.
ArmorTinned copper wire mesh conforming to IEC 60092-350.
External CoverHalogen-free thermoset compound, SHF2, or halogen-free mud-resistant thermoset compound, SHF MUD.
Cover ColorRed.
Mechanical and Thermal Characteristics
Temperature Range-20 ° C to + 90 ° C.
Radius of Curvature (Installation)15 x Outer Diameter.
Radius of Curvature (Fixed Installation)9 x Outer Diameter.
Flame retardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1,2.
Low smoke emissionYes, in accordance with IEC 61034-1,2.
Mud resistantYes (for the SHF MUD type).
Ambient Temperature Correction Factors
35°C1.10
40°C1.05
45°C1.00
50°C0.94
55°C0.88
60°C0.82
65°C0.74
70°C0.67
75°C0.58
80°C0.47
Applicable Standards
NEK 606:2016IEC 60092-354
IEC 60092-360IEC 60332-1
IEC 60332 3 22IEC 60754-1,2
IEC 61034-1,2IEC 60228
IEC 60092-350
Ambient Temperature (°C)35404550556065707580
Classification Factor1.101.051.00.940.880.820.740.670.580.47
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area) (mm²)Nominal Conductor Diameter (mm)Nominal Insulation Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Maximum DC Resistance @20°C (Ω/km)DC Current Capacity @45°C (1 Conductor) (A)DC Current Capacity @45°C (3 Conductors) (A)Short-Circuit Current (1s) (A)Operating Voltage (KV)
1 x 256.54.51.61.228.413057341278935808.715 /
1 x 357.44.51.61.329.3143052915711050108.715 /
1 x 508.74.51.71.330.7162039119613771508.715 /
1 x 7010.34.51.31.832.419000.27242169100208.715 /
1 x 9512.24.51.41.834.42250195293205135908.715 /
1 x 12013.84.51.91.536.62625154339237171708.715 /
1 x 15015.14.52.01.538.12940126389272214608.715 /
1 x 18517.04.51.52.040.635450.1444311264708.715 /
1 x 24019.64.51.62.143.44220762522365343408.715 /
1 x 30021.94.51.72.246.35070607601421429308.715 /
3 x 256.54.51.92.655.347257341278935808.715 /
3 x 357.44.52.72.057.5521552915711050108.715 /
3 x 508.74.52.82.060.6596039119613771508.715 /
3 x 7010.34.52.12.964.470350.27242169100208.715 /
3 x 9512.24.53.12.268.78370195293205135908.715 /
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.